• Title/Summary/Keyword: Universal fairlead

Search Result 1, Processing Time 0.014 seconds

A Study on the Development and Strength Evaluation of the Mooring Fittings with Big Capacity (선박용 대형 계류장비의 개발과 강도 평가)

  • Kim, Young-sig;Kim, Ul-nyeon;Kim, Mi-hee;Kim, Kyoung-youn
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.1-7
    • /
    • 2017
  • It has been developed large mooring fittings having the capacity of 160 tons and 180 tons installed on 170K LNG FSRU. The finite element analysis for the mooring fittings was carried out in order to check the structural integrity and to confirm satisfaction of the rule requirements. The 3 kinds of mooring fittings such as chock, bollard and universal fairlead are selected for FE analysis and load test. According to the FE analysis results, all the stress levels satisfied the acceptance criteria guided by the IACS UR A2, ISO standard, ship rules and OCIMF. As test results under design load, no structural defects were found.