• 제목/요약/키워드: Units of Analysis

검색결과 2,911건 처리시간 0.033초

Ada 프로그램의 Visibility Graph 생성모델에 관한 연구 (A Study on Visibility Graph Generating Model of Ada Program)

  • 정중영;김희주;윤창섭
    • 한국국방경영분석학회지
    • /
    • 제16권2호
    • /
    • pp.56-74
    • /
    • 1990
  • Programming-in-the-Large refers to software development environment and includes the organization and representation of a system structure, module decomposition, component dependence analysis, seperate compilation, subsystem and composition identification. The most intricate problem in this environment is the mastery of the structural complexity of large software systems. Ada programming language is tailored to the needs for building of large, integrated software systems from many program units. The visibility graph generating model presented in this paper transforms Ada source program into a visibility graph with nodes for program units and edges for visibility relations among program units. The system description in terms of program units and their visibility relations produced by this model can be utilized for some apects of Programming-in-the-Large environment and also assists designeers, programmers, integrators and maintainers in defining, understanding and exploring the structure of evolving software systems. The model designed and implemented in Ada programming language runs on PCs and will remain useful both in practice and as experimental tool.

  • PDF

Action Units(AU)를 사용한 애니메이션 캐릭터 표정 분석 (A Study on Expression Analysis of Animation Character Using Action Units(AU))

  • 신현민;원선희;김계영
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2008년도 제39차 동계학술발표논문집 16권2호
    • /
    • pp.163-167
    • /
    • 2009
  • 본 논문에서는 크게 2단계에 걸쳐 다양한 형태의 얼굴을 가진 2차원 애니메이션 상의 캐릭터 얼굴구성요소를 추출하고 표정을 분석한다. 첫 번째 단계에서는, 기존의 얼굴인식 및 표정인식 분야에서 이용되었던 동적메쉬모델을 간소화하여 캐릭터 얼굴에 적용하기 위한 최적의 표준 메쉬모델을 제작하고, 이 모델을 사용하여 얼굴구성요소의 위치 및 형태정보를 추출한다. 두 번째 단계에서는, 앞 단계에서 추출된 3가지 얼굴구성요소(눈썹, 눈, 입)를 사용하여 FACS(Facial Action Coding System)에 정의된 AU(Action Units) 44개 중 12개의 AU를 사용하여 캐릭터의 5까지 기본적인 얼굴 표정에 대해 분석 및 정의한다. 본 논문에서 정의한 AU로 기본적인 5가지 얼굴표정에 대해 표정분석 정확도를 측정하였고, 서로 다른 캐릭터에 실험함으로써 제안된 AU정의의 타당성을 제시한다.

  • PDF

조기 준비기간과 후공정을 갖는 생산시스템의 분석 (Analysis of a Production Systems with Early Set-up and Post-operation)

  • 김승찬;이호우;안부용
    • 한국경영과학회지
    • /
    • 제22권3호
    • /
    • pp.99-111
    • /
    • 1997
  • We consider a production system with post-operation and early set-up. As soon as there are no more units(raw materials) to process and the machine becomes idle, it undergoes a post-operation. After the post operation, if the number of waiting units is greater than or equal to m, it begins a set-up. After the set-up, if the number of units is greater than or equal to N($\geq$m), it begins to process the units. We first analyze the system by employing the decomposition property of the vacation queue. We, then, propose an algorithm that finds the optimal threshold values ($m^*$, $N^*$). Finally we present some numerical examples and interprete the system behavior.

  • PDF

A study on Visual Expression to express Sound Characteristics of Public Places

  • Park, Dong-Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권4호
    • /
    • pp.11-21
    • /
    • 2021
  • The causes of noise generation according to the classification of indoor spaces are very diverse. Individual happiness is infringed by this noise. In this paper, We tried to visualize the spatial sound characteristics of public places using sound color to express them so that anyone can sympathize. The noise inside a conference room of a medical device company was measured for 100 minutes, and the frequency band was divided into three different types of existing sound pressure expression units. Because the size of the noise is expressed differently depending on the situation, There are cases where there is a difference of opinion between the measurer and the researcher. This noise measurement experiment was conducted, and the sound color was applied to classify it on a log scale considering auditory characteristics. As a result of comparing this with the result expression for different loudness expression units, A specific table in different units yielded almost similar results. In addition, the sound source section for 100 minutes was divided into three analysis sections, the analysis sections were different, and the size of the energy ratio for each analysis section was divided in the form of an envelope. The characteristics of the low-frequency region of the space have a high energy ratio, and the decrease in the energy ratio according to the increase in frequency is constant and regular. You can see that conversations are possible.

Loss of Coolant Accident Analysis During Shutdown Operation of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.17-28
    • /
    • 1999
  • A thermal-hydraulic analysis is conducted on the loss-of-coolant-accident (LOCA) during shutdown operation of YGN Units 3/4. Based on the review of plant-specific characteristics of YGN Units 3/4 in design and operation, a set of analysis cases is determined, and predicted by the RELAP5/MOD3.2 code during LOCA in the hot-standby mode. The evaluated thermal-hydraulic phenomena are blowdown, break flow, inventory distribution, natural circulation, and core thermal response. The difference in thermal-hydraulic behavior of LOCA at shutolown condition from that of LOCA at full power is identified as depressurization rate, the delay in peak natural circulation timing and the loop seal clearing (LSC) timing. In addition, the effect of high pressure safety injection (HPSI) on plant response is also evaluated. The break spectrum analysis shows that the critical break size can be between 1% to 2% of cold leg area, and that the available operator action time for the Sl actuation and the margin in the peak clad temperature (PCT) could be reduced when considering uncertainties of the present RELAP5 calculation.

  • PDF

한국 수산업협동조합의 경영효율성 평가 : 자료포락분석 (Evaluating Managerial Efficiency of Fisheries Cooperatives in Korea : Data Envelopment Analysis)

  • 최정윤;남수현;강석규
    • 수산경영론집
    • /
    • 제34권2호
    • /
    • pp.109-129
    • /
    • 2003
  • The purpose of this study is to evaluate the managerial efficiency of fisheries cooperatives in Korea by using data envelopment Analysis(DEA). The DEA method is a relative evaluation method on the basis of linear programming. Also, it is known as a useful method for the evaluation of not-for-profit organizations which cannnot be measured by mere monetray units for their performances. The 50 units have been taken for the purpose of analysis. All of the units are homogeneous groups, and the produce multiple services with multiple inputs. Input variables are a number of employee, fixed assets, and business managerial costs. Output variables include a number of deposits, a number of loans, a total deposits, a total loans, and operational income for one year. The empirical results of this study are as follows. First, the average technical efficiency showed 82.35% which revealed about 17.65% of non-efficiency in 2001. Second, in 15 DMUs, the overall inefficiency is mainly attributed to their efficient operations or management. To be opposed, in 18 DMUs, the overall inefficiency is mainly attributed to their scale efficiency. Third, efficiency ranking results by DEA do not agree with the ratio analysis by fisheries cooperatives. Fourth, average efficiency level by year was improving gradually by 0.7408 in 1999, 0.8023 in 2000, and 0.8235 in 2001 at significant 10% level.

  • PDF

울진 원자력발전소 5,6 호기용 공기정화기에 대한 내진검증 (Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6)

  • 김진영;이희남;이준근
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1376-1383
    • /
    • 2002
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

울진 원자력발전소 5,6호기용 공기정화기에 대한 내진검증 (Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6)

  • 이준근;김진영;정필중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.404-409
    • /
    • 2001
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed is condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

  • PDF

$2{\times}3$행렬구조를 갖는 초전도 한류기의 퀜치특성 분석 (Analysis on the quenching characteristics of a superconducting fault current limiter with 2 by 3 matrixes)

  • 조용선;박형민;이주형;정병익;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2210-2211
    • /
    • 2008
  • In this paper, we investigated the quenching characteristics of a superconducting fault current limiter (SFCL) with connection of $2{\times}3$ matrixes. This SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit the fault current. When the fault occurs, the magnetic field generated in the reactor connected in parallel was applied to the two superconducting units of the current-limiting part to reduce of inhomogeneous critical current behavior between the superconducting units. The quenching behavior of a superconducting unit in the trigger part was affected by the increase of turn numbers. This is because of the difference of current distribution between the inductance of the reactors and the resistance generated in the superconducting units in trigger part. We confirmed that the voltage differences between two superconducting units of the current-limiting part were decreased. This is because of the improvement of inhomogeneous critical current behavior between the superconducting units according to the increase of external magnetic field.

  • PDF

Optimal synthesis for retrofitting heat exchanger network

  • Lee, In-Beum;Jung, Jae-Hak;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1259-1264
    • /
    • 1990
  • During the past two decades, a lot of researches have been done on the synthesis of grassroot heat exchanger networks(HEN). However, few have been dedicated to retrofit of existing heat exchanger networks, which usually use more amount of utilities (i.e. steam and/or cooling water) than the minimum requirements. This excess gives motivation of trades-off between energy saving and rearranging investment. In this paper, an algorithmic-evolutionary synthesis procedure for retrofitting heat exchanger networks is proposed. It consists of two stages. First, after the amount of maximum energy recovery(MER) is computed, a grass-root network featuring minimum number of units(MNU) is synthesized. In this stage, a systematic procedure of synthesizing MNU networks is presented. It is based upon the concept of pinch, from which networks are synthesized in a logical way by the heuristics verified by the pinch technology. In the second stage, since an initial feasible network is synthesized based on the pre-analysis result of MER and must-matches, an assignment problem between new and existing units is solved to minimize total required additional areas. After the existing units are assigned, the network can be improved by switching some units. For this purpose, an improvement problem is formulated and solved to utilize the areas of existing units as much as possible. An example is used to demonstrate the effectiveness of the proposed method.

  • PDF