• Title/Summary/Keyword: Unit-to-unit

Search Result 26,159, Processing Time 0.058 seconds

CUMAP : A Chill Unit Calculator for Spatial Estimation of Dormancy Release Date in Complex Terrain (Chill Unit 축적과 휴면해제시기 공간변이 추정 프로그램 : CUMAP)

  • Kim Kwang S.;Chung U ran;Yun Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.3
    • /
    • pp.177-182
    • /
    • 2004
  • A chill unit has been used to estimate chilling requirement for dormancy release and risk of freezing damage. A system that calculates chill units was developed to obtain site-specific estimates of dormancy release date for grapes and evaluated in Baekgu myun near Kimje City, Chunbuk, Korea from September 2002 to March 2003. The system utilized daily minimum and maximum temperature maps generated from spatial interpolation with temperature correction for topography. Hourly temperature was temporally interpolated from the daily data using a sine-exponential equation (Patron and Logan, 1981). Hourly chill units were determined from sigmoid, reverse sigmoid, and negatively increasing sigmoid functions based on temperature ranges and summed for 24 h. Cumulative daily chill units obtained from measurements did not increase until 20 October 2002, which was used as a start date for accumulation to estimate the dormancy release date. As a result, a map of dormancy release date in the study area was generated, assuming 800 chill units as a threshold for the chilling requirement. The chill unit accumulation system, implemented using Microsoft Visual Basic and C++ (Microsoft, Redmond, WA, USA), runs in the Windows environment with ArcView (ESRl Inc., Redlands, CA, USA).

Domestic Development of Vibrational Film Forming Machine and Die and Mold in the High Speed Production(I) - Single production forming machine - (고속 생산형 필름 진동판 성형기 및 금형 국산화 개발(I) - 단수 생산 진동판 성형기 -)

  • Kim, Jung-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-15
    • /
    • 2012
  • Vibrational film has been more employed in ear-phones or small type of speakers along with a wide use of portable multi-media equipments such as MP3 and MP4. However, the current hand work production process of diaphragms is inefficient. In this study, a die-and-mold and a single production forming machine are developed, and they result in a multi-production forming machine. The multi-production forming machine consists primarily of a film feeding unit and an unwinding unit. A vacuum suction device provides the film feeding unit, while the unwinding unit is obtained using an appropriate damper. The advantage of the developed single production forming machine is shown according to a proper voice test.

Cost Analysis Model with Minimal Repair of Spare Unit Repair Policy under Periodic Maintenance Policy (정기보전 제도에서 응급수리를 고려한 대체품 수리정책에서의 비용분석 모델)

  • Kim Jae-Joong
    • Journal of Applied Reliability
    • /
    • v.6 no.2
    • /
    • pp.151-161
    • /
    • 2006
  • This article is concerned with cost analysis model in periodic maintenance policy. The repair policy is differently applied according as unit importance during an item being used and unit restoration during an item being failed. So in this paper the repair policy with minimal repair is considered as follow : as the occurrence of failure between minimal repair and periodic interval time, unit is replaced by a spare unit until the periodic maintenance time arrived. Then total expected cost per unit time is calculated according to scale parameter of failure distribution in a view of customer's. The total expected costs are included repair and usage cost : operating, fixed, minimal repair, periodic maintenance and spare unit cost. Numerical example is shown in which failure time of item has Erlang distribution.

  • PDF

Development of 100 Kw Power Class Airborne Auxiliary Power Unit (100 Kw급 항공용 보조동력장치(APU) 개발)

  • Yang, Soo-Seok;Lee, Dae-Sung;Kim, Seung-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.291-300
    • /
    • 1999
  • Currently under development is an airborne auxiliary power unit with 100 Kw equivalent power, which is composed of a centrifugal compressor, a reverse annular combustor, and a radial turbine. Air-foil bearings are used in this power unit to eliminate the oil supplying system, which can reduce the system complexity and weight. The high speed generator is adopted as an electric power generation and engine starting system, which can also eliminate the reduction gear system. Not only electric power but also pneumatic power is provided by bleeding the compressed air This power unit is aimed for the multi-purpose use such as a primary power unit In the army weapon system, an auxiliary power and environmental control unit in a next-generation tank, and a smoke generating unit.

  • PDF

The method for the classification according to their kinds and the estimation of unit generation rate for promoting recycling of construction and demolition(c&d) debris (건설폐기물 재활용촉진을 위한 종류별 분류 및 발생원단위 산정 방안)

  • Lee, Hi Sun;Kim, Dong Sik
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.86-100
    • /
    • 2008
  • It is needed to classify the kinds of construction and demolition(c&d) debris to 6 catagories of waste concrete, waste asphalt concrete, waste wood, scraps, combustible waste and incombustible waste in order to properly do a separate discharge and to estimate unit generation rate in construction site. Also, in this case, the unit treating cost for mixed wastes should be applied with the unit treating cost for combustible waste. The construction standard materials estimation data is used for basic data for estimating unit generation rate. The mixed wastes in this data should be classified to waste wood, combustible waste and incombustible waste, and their ratio is obtained by using the unit generation rate of Asia Pacific Environment and Management Institute and Seoul Metropolitan Development Institute. The waste amounts generated from newly-built construction can be obtained from multiplying the loss rate by the amount of materials used from construction standard estimation data. Also, those from dismantling construction can be obtained by subtracting waste amount generated during newly-built construction from total input amount of materials in newly-built construction. Those in two cases can be used in construction site. It can be used for estimating the amount generated and establishing the treating plan in the case of setting up the policy of waste management and doing the environment impact assessment.

  • PDF

A Study on the Architectural Planning of the Angiography Unit in General Hospital (종합병원 혈관조영촬영유니트의 건축계획에 관한 연구)

  • Yun, Woo-Yong;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.69-77
    • /
    • 2006
  • Angiography means that a check up to know an abnormal condition in all the blood vessels include from the heart, aortae, cerobrovascular and abdonominal artery to hands and feet. Main examples of this are cerebral angiography, abdominal, liver for urinary anomaly, renovascular angiography, and artery and vein in arms and legs. Angiography uses radial rays or angiography equipment for an image output during interventional procedure and compositive diagnosis. The acts which performed in a projection room have changed drastically. In general, it is performed by using equipment which is attached one or two C-arms and the method of inserting catheter in vein after anesthesia. For this reason, some rooms that consist of angiography room units should be planned not only for expensiveness equipment and facilities also to be germ-free. Nowadays, in the angiography unit case, it is placed independently as the central part of many hospitals. It does not belong to the imaging medical department any more as considering raising filming times and the relation between C.C.U.(coronary care unit) and operation unit. This means the acts performed are diversified and well-organized rooms in support of diagnosis are required. However, it is difficult to plan the angiography room unit due to domestic researches and data on this unit are not enough. Therefore, this study aims at bringing up basic issue for architectural planning of the angiography unit in general hospital.

  • PDF

HELIUM CONCENTRATION DECREASE DUE TO AIR ENTRAINMENT INTO GLASS FIBER COOLING UNIT IN A HIGH SPEED OPTICAL FIBER DRAWING PROCESS (광섬유 고속인출공정용 유리섬유 냉각장치 내 공기유입에 의한 내부헬륨농도 저하현상 연구)

  • Kim, K.;Kim, D.;Kwak, H.S.;Park, S.H.;Song, S.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.4
    • /
    • pp.92-98
    • /
    • 2010
  • In a modern high speed drawing process of optical fibers, it is necessary to use helium as a cooling gas in a glass fiber cooling unit in order to sufficiently cool down the fast moving glass fiber freshly drawn from the heated silica preform in the furnace. Since the air is entrained unavoidably when the glass fiber passes through the cooling unit, the helium is needed to be injected constantly into the cooling unit. The present numerical study investigates and analyzes the air entrainment using an axisymmetric geometry of glass fiber cooling unit. The effects of helium injection rate and direction on the air entrainment rate are discussed in terms of helium purity of cooling gas inside the cooling unit. For a given rate of helium injection, it is found that there exists a certain drawing speed that results in sudden increase in the air entrainment rate, which leads to the decreasing helium purity and therefore the cooling performance of the glass fiber cooling unit. Also, the helium injection in aiding direction is found to be more advantageous than the injection in opposing direction.

Evaluation of Menu Management and Nutrition Supply in Industrial Foodservice by Food Cost (식품원가 분류에 따른 산업체급식의 식단관리 및 영양공급량평가)

  • Park, Myung-Hee;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.8 no.2
    • /
    • pp.91-101
    • /
    • 1993
  • Unit price of meal provision in industrial foodservice differs with each business. It is believed that menu management work, contents of menu, and nutrition supply performed by dietitian are different with unit price of meal provision. In this sense, purposes of this study are to examine meal management work and contents of menu, by food cost, at industrial foodservice in Taegu, Kyungbuk area and to evaluate variety of menu and nutrition supply. Results of the study are as follows: 1. Average number of side dishes provided at meal, including Kimchi, was 2 at low unit price, 3.0 at middle unit price and 3.1 at high unit price. 2. Possession ratio of account books using for menu management was low. 3. With regard to kind of menu, high unit price was most various and showed more various, compared to low unit price, especially in cooking oil-used cook methods such as broil, pan-fried food, fry, and roast. 4. High unit price was found as the highest in kind of used food and supply volume. 5. Sugar, Mineral, Vitamine, and Protein were satisfied with standard food content, but fat and calcium were not. 6. Supply volume of food was positively correlated to supply volume of nutrient, but kinds of cook methods and food type were not correlated to that of nutrient.

  • PDF

Design of AMBA AX I Slave Unit for Pipelined Arithmetic Unit (파이프라인 구조 연산회로를 위한 AMBA AXI Slave 설계)

  • Choi, Byeong-Yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.712-713
    • /
    • 2011
  • In this paper, the AMBA AXI slave unit that can verify the pipelined arithmetic unit is proposed and the 2-stage 16-bit pipelined multiplier is introduced as design example. The proposed AXI slave unit consists of input buffer block memory, control registers, pipelined arithmetic unit, control unit, output buffer block memory, and AXI slave interface unit. The main operational procedures are divided into the following steps, such as burst-mode input data loading for the input buffer memory, programming of control registers, arithmetic operations for block data in the input buffer memory, and burst-mode output data unloading from output buffer memory to host processor. Because the proposed AXI slave unit is general structure, it can be efficiently applicable to AMBA AXI and AHB slave unit with pipelined arithmetic unit.

  • PDF

Characteristics Analysis on the Unit Plans of Apartment Houses in Jeon-ju City - Spacial tendency was focused on the unit size of $69.42-115.70m^2$ - (전주시 아파트 주거의 평면적 특성 분석 - 21-35평형을 중심으로 변화 추이 -)

  • Choi Byung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.102-110
    • /
    • 2006
  • The purpose of this study was to find out the spacial characteristics from the $69.42-11.70m^2$ unit plans of the apartment houses in Jeon-ju city, and to check up on the general spacial principles of Korean apartment unit plans. The content analysis method and the survey method were used for this study. The data of apartment unit plans and the questionnaires were collected from apartment offices or real estate agency offices. The data of 157 unit plans and 190 questionnaires were analyzed. The results of this study were as follows; 1) The general spacial principles of Korean apartment unit plans, the tendency of front 3-bay unit plan, the openness of living room, the Anbang with a bathroom and a dressroom, the utility room as a kitchen support space, and the addition of balconies, were showed in those of Jeon-ju city. 2) There was a new tendency, the front room arrangement of Anbang-living room-bedroom was changed into Anbang-living room-bathroom or kitchen, in them. 3) The characteristics of L-DK floor plans that the closeness of DK from exterior space and the interior openness and exterior privacy of L were showed in them. 4) The entrance was needed a intermediate space as a balcony or a former space, in them. These tendencies on unit plans of the apartment houses in Jeon-ju city were followed the general spacial principles of Korean apartment unit plans.