• Title/Summary/Keyword: Unit-to-unit

Search Result 26,159, Processing Time 0.052 seconds

A Study on Statistical Characteristics of Space Dimension of 60 m2, 85 m2 Size Apartment Plan Types in Seoul (전용면적 60 m2, 85 m2 아파트 평면 유형에서 실 치수의 통계적 특성에 관한 연구)

  • Kim, Min-Kyoung;Yoon, Chae-Shin
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.53-65
    • /
    • 2010
  • Apartment buildings represent the most typical patterns of housing in Korea. The present plans are very different from the previous ones when they appeared for the first time. Although apartment unit plans has changed drastically, they can be classified into several categories. Apartment unit plans reflects the demands of living activities and space dimensions of unit plans have the characteristics of diachronic continuity and carry the values of living culture. Thus this study aims to provide the statistical dimensional data of each room that can be actually used for the design of unit plans by sub-grouping typical unit plans. The statistical data of this study showed that apartment unit plans are shifting from 2bay/3room type to 3bay/3room type in 1990s. It is very peculiar that the typical unit plan of $60\;m^2$ area becomes to resemble that of $85\;m^2$ area. The space arrangement of typical unit plans of both $60\;m^2$ and $85\;m^2$ area is almost identical while only their space dimensions differ slightly. As the mean/mode/median values of space dimensions in a typical unit plan are converging into a range of narrow margin, space dimensions of typical unit plan are contended to be strictly regular. The statistical numeric data of various space dimensions provided in this paper can be applied practically to the design of apartment unit plans for low income class people who are disprivileged in the society.

Superoxide Dismutase and Peroxidase Activity of Transformed Callus in Tomato (형질전환된 토마토 캘러스의 Superoxide Dismutase와 Peroxidase 활성)

  • 유정민;정형진;김경민;곽상수
    • Korean Journal of Plant Tissue Culture
    • /
    • v.25 no.3
    • /
    • pp.177-181
    • /
    • 1998
  • This study was carried out to investigate activity difference in the superoxide dismutase (SOD) and peroxidase (POD) of tomato callus transformed with Agrobacterium containing the GUS gene. Than those of other two tomato cultivars, the hypocotyl explant of JA101 was shown to have higher POD and SOD specific activity of 23 unit/mg protein and 2,156 unit/mg protein, respectively. Relatively high frequency of callus formation was obtained from the hypocotyl explant on MS medium containing 1 mg/L 2,4-D for 30 days and its POD(47 unit/mg protein) and SOD (95,786 unit/mg protein) specific activities were higher than other 2,4-D concentration. The hypocotyl explant and callus cocultivated with Agrobacterium for 72 hours were transferred to MS medium supplemented with 1 mg/L 2,4-D, 30 mg/L kanamycin, 30 g/L sucrose and 4 g/L Gelrite. The hypocotyl explants transferred to the medium formed callus with 45.5% effeciency after 8 weeks. The transformation efficiency confirmed by GUS assay was 21.6%. POD specific activity of the transformed callus (54 unit/mg protein) were somewhat lower than the non-transformed callus (64 unit/mgg protein) and SOD specific activity of the transformed callus (30,300 unit/mg protein) were also lower than the non-transformed callus (37,077 unit/mg protein). However there was no significant difference in POD and SOD isozyme patterns between the transformed and the non-transformed calluses. From these results, it revealed that there was no difference of antioxidant enzyme activities between the transformed callus and the non-transformed callus in tomato.

  • PDF

A Study of the Specific Items and Contents of District Unit Plan for Responding to Commercial Gentrification - Focused On the 'District Unit Plan' of Seochon, Ikseon and Ttukseom surrounding area - (젠트리피케이션 대응을 위한 지구단위계획 항목 및 내용 분석 - 경복궁서측, 익선, 뚝섬주변지역 지구단위계획을 대상으로 -)

  • Kim, Su-young;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.10
    • /
    • pp.103-114
    • /
    • 2019
  • This study analyzed the specific items and contents of district unit plan for responding to commercial gentrification on the west side of Gyeongbokgung Palace, Ikseon and Ttukseom surrounding area. By analyzing the major regulatory items and ranges currently used in the 'district unit plan' for responding to gentrification, it was intended to draw up the limitations of the district unit plan of the study target and the significant issues to be considered when establishing a district unit plan for future respond to gentrification. In the district unit plan around Seochon, Ikseon and Ttukseom surrounding area, location restrictions are imposed on franchises for responding to gentrification in common, and in the case of Ikseon and Ttukseom surrounding area, the maximum development scale is especially smaller than that of the surrounding areas. Also, in the Ttukseom surrounding area, incentives are given to the use of certain exterior materials to preserve regional characteristics.

A Study on the Correlation of Residential Satisfaction of Dwellers and the Size of Housing Unit in Apartment Housing (공동주택규모와 옥내외 물리적 주거환경만족도의 상관관계 연구)

  • Kim, Gi Soo;Shin, Jin-Hwan
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.101-108
    • /
    • 2013
  • The purpose of this research was to analyze the correlation of residential satisfaction and the size of housing unit in apartment housing through the case study of 1,619 samples of 36 housing estates. The contents of this research consisted of two main parts. The first part was to identify the differences of residential satisfaction of dwellers, based on the size of housing unit, in apartment housing. The second part was to analyze the characteristics of residential environment, which might have an influence on the differences of residential satisfaction. the findings of this study were that the residential satisfaction of dwellers was proportional to the size of housing unit except $39m^2$ under housing unit, and the size of housing unit was not proportional to the residential satisfaction of outdoor openness exactly, but the size of housing unit was proportional to increase of the distance between building and building, and decrease of the building surface coverage ratio to outdoor area. This research will contribute to the establishment of the site planning methods which increase residential satisfaction in apartment housing, while promoting the quality of residential environment in Korea.

The Studying on Drum-type Hill-drop Unit

  • Zhang, Xuejun;Yang, Yin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.996-998
    • /
    • 1996
  • The drum-type hill-drop unit, an important working device of the plastic -film-covered hill planter, can finish filling and separating seed precisely, perforating film and holing , and its seeding depth and spacing are stability . The unit is applied to hole seed many crops, for example, cotton, corn , soybean, etc. The drum-type hill-drop unit(DHU) , the key work unit to the plastic film-covered planter, mainly consists of distributor box , seeding parts, hole forming unit and drum , It can be operated to accomplish seeds distributing, hole forming , plastic film perforating . Moreover , its inner cavity can be used as seed box.

  • PDF

A Study on Simulation Methodology for Energy Consumption of Complex Unit Apartment Housings (단지 규모 주택의 에너지 사용량 시뮬레이션 방법론에 관한 기초연구)

  • Kim, Min-Hwan;Nam, Hyun-Jin;Kim, Dong-Ho;Yook, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.931-936
    • /
    • 2008
  • The need for urban-scale energy simulation is increasing as the world is aware of urgency to decrease $CO_2$ emission. As a bridge of building energy simulation and that of urban, this paper presents a case study to examine the effect of changing resolution of a model in case of complex apartment unit. Also it suggests a modeling strategy to correct differences caused by simplification of the model and evaluate the extent of its use.

  • PDF

Estimation of water unit factor and water demand of domestic airports (공항용수 원단위 산정 및 용수 사용량 추정방법)

  • Kim, Taeyoung;Kim, Taehwan;Huh, Dong;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.231-239
    • /
    • 2009
  • The purpose of this research is to provide more reliable water unit factors of domestic airports by investigating of general informations related to the domestic airport. The informations of domestic airports such as passengers, settled population of airports, building areas and water amount are investigated to estimate the unit factor of water of domestic airports. The domestic airports are divided into three type such as central airport, position airport and general airport. Through analysis of relationship between water amount and the others, the unit factor of water could be calculated. The water amount of central airport as Incheon international airport and position airports could be estimated by unit factor of settled population. The others could be estimated by unit factor of building area.

Design of an Instruction Fetch Unit for RAPTOR, a On-Chip Multiprocessor (RAPTOR의 명령어 페치 유닛 설계)

  • 이성권;오형철이상원한우종
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.767-770
    • /
    • 1998
  • This paper introduces an instruction fetch unit which is designed for RAPTOR, an on-chip multiprocessor. In order to reduce control hazards, the proposed fetch unit supports a hybrid branch prediction scheme which consists of a static scheme and the 2bC branch prediction scheme. The fetch unit also utilizes the branch folding technique with two instruction buffers to avoid the branch penalty caused by imspredictions. Instructions are predecoded in the fetch unit to achieve extra performance gain.

  • PDF

Fabrication Characteristics and Performance Evaluation of a Large Unit Cell for Solid Oxide Fuel Cell (고체산화물연료전지용 대면적 단위전지 제조특성 및 성능평가)

  • Shin, Y.C.;Kim, Y.M.;Oh, I.H.;Kim, H.S.;Lee, M.S.;Hyun, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.13-16
    • /
    • 2008
  • Solid oxide fuel cell(SOFC) is an electrochemical energy conversion system with high efficiency and low-emission of pollution. In order to reduce the operating temperature of SOFC system under $800^{\circ}C$, the thickness reduction of YSZ electrolyte to be as thin as possible, e.g., less than 10 ${\mu}m$ are considered with the microstructure control and optimum design of unit cell. Methods for reducing the thickness of YSZ electrolyte have been investigated in coin cell. Moreover, a large unit cell($8cm{\times}8cm$) for SOFC was fabricated using an anode-supported electrolyte assembly with a thinner electrolyte layer, which was prepared by a tape casting method with a co-sintering technique. we studied the design factors such as active layer, electrolyte thickness, cathode composition, etc,. by the coin type of unit cell ahead of the fabrication process of a large unit cell and also reviewed about the evaluation technique of a large size unit cell such as interconnect design, sealing materials and current collector and so forth. Electrochemical evaluations of the unit cells, including measurements such as power density and impedance, were performed and analyzed. Maximum power density and polarization impedance of coin cell were 0.34W/$cm^2$ and $0.45{\Omega}cm^2$ at $800^{\circ}C$, respectively. However, Maxium power density of a large unit cell($5cm{\times}5cm$) decreased to 0.21W/$cm^2$ at $800^{\circ}C$ due to the increase of ohmic resistance. However, It was found that the potential value of a large unit cell loaded by 0.22A/$cm^2$ showed 0.76V at 100hrs without the degradation of unit cell.

  • PDF

Efficient Motion Information Representation in Splitting Region of HEVC (HEVC의 분할 영역에서 효율적인 움직임 정보 표현)

  • Lee, Dong-Shik;Kim, Young-Mo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.485-491
    • /
    • 2012
  • This paper proposes 'Coding Unit Tree' based on quadtree efficiently with motion vector to represent splitting information of a Coding Unit (CU) in HEVC. The new international video coding, High Efficiency Video Coding (HEVC), adopts various techniques and new unit concept: CU, Prediction Unit (PU), and Transform Unit (TU). The basic coding unit, CU is larger than macroblock of H.264/AVC and it splits to process image-based quadtree with a hierarchical structure. However, in case that there are complex motions in CU, the more signaling bits with motion information need to be transmitted. This structure provides a flexibility and a base for a optimization, but there are overhead about splitting information. This paper analyzes those signals and proposes a new algorithm which removes those redundancy. The proposed algorithm utilizes a type code, a dominant value, and residue values at a node in quadtree to remove the addition bits. Type code represents a structure of an image tree and the two values represent a node value. The results show that the proposed algorithm gains 13.6% bit-rate reduction over the HM-1.0.