• Title/Summary/Keyword: Unit-to-unit

Search Result 25,897, Processing Time 0.04 seconds

A Study on the Operational Events of Domestic Nuclear Power Plants for Multi-unit Risk (원전 다수기 리스크 평가를 위한 국내 원전 사건이력 조사 연구)

  • Lim, Hak Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.167-174
    • /
    • 2019
  • Compared to a single nuclear power plant (NPP) risk, the commonalities existing in the multiple NPPs attribute the characteristics of the multi-unit risk. If there is no commonality among the multiple NPPs, there will be no dependency among the risks of multiple NPPs. Therefore, understanding the commonality causing multi-unit events is essential to assessing the multi-unit risk, and identifying the characteristics of the multi-unit risk is necessary not only to select the scope and method for the multi-unit risk assessment, but also to analyze the data of the multi-unit events. In order to develop Korea-specific multi-unit risk assessment technology, we analyze the multi-unit commonalities included in the operational experiences of domestic NPPs. We identified 58 cases of multi-unit events through detailed review of domestic nuclear power plant event reports over the past 10 years, and the multi-unit events were classified into six commonalities to identify Korea-specific characteristics of multi-unit events. The identified characteristics can be used to understand and manage domestic multi-unit risks. It can also be used as a basis for modeling multi-unit events for multi-unit risk assessment.

Study on multi-unit level 3 PSA to understand a characteristics of risk in a multi-unit context

  • Oh, Kyemin;Kim, Sung-yeop;Jeon, Hojun;Park, Jeong Seon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.975-983
    • /
    • 2020
  • Since the Fukushima Daiichi accident in 2011, concerns for the safety of multi-unit Nuclear Power Plant (NPP) sites have risen. This is because more than 70% of NPP sites are multi-unit sites that have two or more NPP units and a multi-unit accident occurred for the first time. After this accident, Probability Safety Assessment (PSA) has been considered in many countries as one of the tools to quantitatively assess the safety for multi-unit NPP sites. One of the biggest concerns for a multi-unit accident such as Fukushima is that the consequences (health and economic) will be significantly higher than in the case of a single-unit accident. However, many studies on multi-unit PSA have focused on Level 1 & 2 PSA, and there are many challenges in terms of public acceptance due to various speculations without an engineering background. In this study, two kinds of multi-unit Level 3 PSA for multi-unit site have been carried out. The first case was the estimation of multi-unit risk with conservative assumptions to investigate the margin between multi-unit risk and QHO, and the other was to identify the effect of time delays in releases between NPP units on the same site. Through these two kinds of assessments, we aimed at investigating the level of multi-unit risk and understanding the characteristics of risk in a multiunit context.

Multi-unit Level 1 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Kim, Dong-San;Han, Sang Hoon;Park, Jin Hee;Lim, Ho-Gon;Kim, Jung Han
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1217-1233
    • /
    • 2018
  • Following a surge of interest in multi-unit risk in the last few years, many recent studies have suggested methods for multi-unit probabilistic safety assessment (MUPSA) and addressed several related aspects. Most of the existing studies though focused on two-unit nuclear power plant (NPP) sites or used rather simplified probabilistic safety assessment (PSA) models to demonstrate the proposed approaches. When considering an NPP site with three or more units, some approaches are inapplicable or yield very conservative results. Since the number of such sites is increasing, there is a strong need to develop and validate practical approaches to the related MUPSA. This article provides several detailed approaches that are applicable to multi-unit Level 1 PSA for sites with up to six or more reactor units. To validate the approaches, a multi-unit Level 1 PSA model is developed and the site core damage frequency is estimated for each of four representative multi-unit initiators, as well as for the case of a simultaneous occurrence of independent single-unit initiators in multiple units. For this purpose, an NPP site with six identical OPR-1000 units is considered, with full-scale Level 1 PSA models for a specific OPR-1000 plant used as the base single-unit models.

Genome-wide SNP analysis provides insights into the XX/XY sex-determination system in silver barb (Barbonymus gonionotus)

  • Visarut Chailertrit;Thitipong Panthum;Lalida Kongkaew;Piangjai Chalermwong;Worapong Singchat;Syed Farhan Ahmad;Ekaphan Kraichak;Narongrit Muangmai;Prateep Duengkae;Surin Peyachoknagul;Kyudong Han;Kornsorn Srikulnath
    • Genomics & Informatics
    • /
    • v.21 no.4
    • /
    • pp.47.1-47.12
    • /
    • 2023
  • Silver barb (Barbonymus gonionotus) is among the most economically important freshwater fish species in Thailand. It ranks fourth in economic value and third in production weight for fisheries and culture in Thailand. An XX/XY sex-determination system based on gynogenesis was previously reported for this fish. In this study, the molecular basis underlying the sex-determination system was further investigated. Genome-wide single-nucleotide polymorphism data were generated for 32 captive-bred silver barb individuals, previously scored by phenotypic sex, to identify sex-linked regions associated with sex determination. Sixty-three male-linked loci, indicating putative XY chromosomes, were identified. Male-specific loci were not observed, which indicates that the putative Y chromosome is young and the sex determination region is cryptic. A homology search revealed that most male-linked loci were homologous to the Mariner/Tc1 and Gypsy transposable elements and are probably the remnants of an initial accumulation of repeats on the Y chromosome from the early stages of sex chromosome differentiation. This research provides convincing insights into the mechanism of sex determination and reveals the potential sex determination regions in silver barb. The study provides the basic data necessary for increasing the commercial value of silver barbs through genetic improvements.

Stratigraphic Sequence and Depositional Environment of Unconsolidated Deposits in the West Seacoast (서해안 미고결 지층의 퇴적이력 및 퇴적환경)

  • Lee, Yong-Mok;Choi, Eun-Kyeong;Kim, Sung-Wook;Lee, Kyu-Hwan;Yoon, Yeo-Jin;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.10
    • /
    • pp.55-68
    • /
    • 2012
  • The west seacoast has approximately 83% of tidal flat in Korea. Gyeonggi-do and Inchon has 35.1%. This study was carried out to understand depositional environment and properties of tidal deposits that distributed in the Gyeonggi bay. On the basis of observation and description on mineralogical, geochemical, physical properties, detailed sedimentary unit has been respectively distinguished Based on. stratigraphic position, facies and unconformity, the intertidal zones are classified into four sedimentary units, and bedrock over the units has been developed in the order of Unit 4${\rightarrow}$Unit 3${\rightarrow}$Unit 2${\rightarrow}$Unit 1. The intertidal sediment deposits of Gyeonggi Bay were compared with those of west coast. In Cheongra area all strata of Unit 4-Unit 3-Unit 2-Unit 1 appear. In Yeongjong-do Unit 2-Unit 1, in Incheon Bridge and Songdo area Unit 4-Unit 3-Unit 1 are observed. In Daesan area Unit 4-Unit 3-Unit 1 are observed. Average clay mineral content ratio is 8.2% in Cheongra area, 2.9% in Yeongjong Island, 18.4% in Incheon Bridge, 24.6% in Songdo area.

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

A Study on the Homemakers' Housing Notion according to Unit Size in Apartment - focus on 20pyung∼50pyung - (공동주택 평형별 주부들의 주거관에 관한 조사연구 - 20평형대∼50평형대를 중심으로 -)

  • 장경수;김경순
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.116-124
    • /
    • 2003
  • The purpose of this study was provide basic data for homemakers' housing notion according to unit size in apartment. This study was conducted by questionnaires that concerning about middle class homemakers whom they lived in Bundang. The results of this study were as follows; 1) In research on the homemakers' general quality, 20pyung unit size was alike 30pyung unit size and 40pyung unit size was similar to 50pyung unit size. 2) Homemakers' perception according to unit size in apartment was various; (a) 20pyungㆍ30pyung unit size-effective household space for husbands' participation, more sports facilities, parking lot space etc. (b) 40pyungㆍ50pyung unit size-homemakers' individual room, ordering and variable unit plan etc. 3) In research on the homemakers' needs, each of unit size was analogous to storage, common facility, new design and new housing form etc.

A study on evaluation of information retrieval system (정보검색(情報檢索)시스템의 평가(評価)에 관한 연구(硏究))

  • Park, In-Ung
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.5 no.1
    • /
    • pp.85-105
    • /
    • 1981
  • Information is an essential factor leading the rapid progress which is one of the distinguished characteristics in modem society. As more information is required and as more is supplied by individuals, governmental units, businesses, and educational institutions, the greater will be the requirement for efficient methods of communication. One possibility for improving the information dissemination process is to use computers. The capabilities of such machine are beginning to be used in the process of Information storage, retrieval and dissemination. An important problems, that must be carefully examined is whether one technique for information retrieval is better for worse than another. This paper examines problem of how to evaluate an information retrieval system. One specific approach is a cost accounting model for use in studying how to minimize the cost of operating a mechanized retrieval system. Through the use of cost analysis, the model provides a method for comparative evaluation between systems. The general cost accounting model of the literature retrieval system being designed by this study are given below. 1. The total cost accounting model of the literature retrieval system. The total cost of the literature retrieval system = (the cost per unit of user time X the amount of user time) + ( the cost per unit of system time X the amount of system time) 2. System cost accounting model system cost = (the pre-search system cost per unit of time X time) + (the search system cost per unit of time X time) + (the post search system cost per unit of time X time) 1) Pre-search system cost per unit of time = cost of channel per unit time + cost of central processing unit per unit time + cost of storage per unit time 2) Search system cost per unit of time = comparison cost + document representation cost. 3) Post-search system cost per unit of time. = cost of channel per unit time + cost of central processing unit per unit time + cost of storage per unit time 3. User cost accounting model Total user cost = [pre-search user cost per unit of time X (time + additional time) ] + [search user cost per unit of time X (time + additional time) ] + [post-search user cost per unit of time X (time + additional time) ].

  • PDF

Human and organizational factors for multi-unit probabilistic safety assessment: Identification and characterization for the Korean case

  • Arigi, Awwal Mohammed;Kim, Gangmin;Park, Jooyoung;Kim, Jonghyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.104-115
    • /
    • 2019
  • Since the Fukushima Daiichi accident, there has been an emphasis on the risk resulting from multi-unit accidents. Human reliability analysis (HRA) is one of the important issues in multi-unit probabilistic safety assessment (MUPSA). Hence, there is a need to properly identify all the human and organizational factors relevant to a multi-unit incident scenario in a nuclear power plant (NPP). This study identifies and categorizes the human and organizational factors relevant to a multi-unit incident scenario of NPPs based on a review of relevant literature. These factors are then analyzed to ascertain all possible unit-to-unit interactions that need to be considered in the multi-unit HRA and the pattern of interactions. The human and organizational factors are classified into five categories: organization, work device, task, performance shaping factors, and environmental factors. The identification and classification of these factors will significantly contribute to the development of adequate strategies and guidelines for managing multi-unit accidents. This study is a necessary initial step in developing an effective HRA method for multiple NPP units in a site.

Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses (공동주택 단위난방부하 계산을 위한 단위동법 제안)

  • Yoo Ho-Seon;Chung Joo-Hyuk;Moon Jung -Hwan;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.