• Title/Summary/Keyword: Unit method

Search Result 7,005, Processing Time 0.033 seconds

Development of Unit Commitment Methodology Considering Direct Load Control by 3-Dimensional Dynamic Programming (3차원 동적계획법에 의한 직접부하제어를 고려한 기동정지계획 방법론의 개발)

  • Lee, Buhm;Kim, Yong-Ha;Choi, Sang-Kyu;Kim, Hyeong-Jung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.12
    • /
    • pp.591-596
    • /
    • 2002
  • This Paper Presents a new methodology for Direct Load Control(DLC) and Unit Commitment. To consider economical effect of DLC, we developed 3-Dimensional dynamic programming which can combine unit commitment and DLC. Traditional dynamic programming has 2-Dimensional which consist of state and stage, but newly developed dynamic programming has DLC state, U.C. state, and stage. As a result, economical DLC and unit commitment schedule of the power system is possible. This method is applied to the test system, and the usefulness of the method is verified.

An Efficient Priority Based Unit Commitment using the Unit Operation Costs and the Probabilistic Reserve Requirements (확률적 운전예비력 및 운전비단가 우선순위법에 의한 화력시스텝의 실제적인 기동- 정지계획)

  • 이봉용;심건보;김정훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.6
    • /
    • pp.331-338
    • /
    • 1988
  • A simple algorithm is presented for solving the thermal unit commitment problem which is one of very important areas in economic operation of power systems. This algorithm is based on simple priority ordering by the unit operation cost and it is shown that the operation cost of chosen sets of generators is the minimum. The proposed method differs from the conventional priority-based formulations in that the unit operation are calculated in every load level. Further the poerating reserve requiements are satisfied by the newly derived analytical security function or the expectation of reserve. The proposed method is proven to be very simple, accurate and efficient in a sample system.

  • PDF

Reproducibility of Statistical Motor Unit Number Estimate in Amyotrophic Lateral Sclerosis: Comparisons between Size-and Number-Weighted Modifications (근위축성 측삭 경화증에서의 Statistical Motor Unit Number Estimate 재연성: Size-and Number-Weighted Modifications간의 비교)

  • Kwon, Oh Yun;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Background: Motor unit number estimation (MUNE) can directly assess motor neuron populations in muscle and quantify the degree of physiologic and/or pathologic motor neuron degeneration. A high degree of reproducibility and reliability is required from a good quantitative tool. MUNE, in various ways, is being increasingly applied clinically and statistical MUNE has several advantages over alternative techniques. Nevertheless, the optimal method of applying statistical MUNE to improve reproducibility has not been established. Methods: We performed statistical MUNE by selecting the most compensated compound muscle action potential (CMAP) area as a test area and modified the results obtained by weighted mean surface-recorded motor unit potential (SMUP). Results: MUNE measures in amyotrophic lateral sclerosis (ALS) patients showed better reproducibility with sizeweighted modification. Conclusions: We suggest size-weighted MUNE testing of "neurogenically compensated"CMAP areas present an optimal method for statistical MUNE in ALS patients.

  • PDF

A Construction of the Improved Hardware Arithmetic Operation Unit (개선된 하드웨어 산술연산기 구성)

  • Park, Chun-Myoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1023-1024
    • /
    • 2015
  • This paper propose the method of constructing the improved hardware arithmetic operation unit over galois fields. The proposed the hardware arithmetic operation unit have advantage which is more regularity and extensibility compare with earlier method. Also it is able to apply to any multimedia hardware which is the basic arithmetic operation unit. For the future we will research the processor which is the processing arithmetic and logical operation.

  • PDF

A Study on the Design criteria of Steel Unit House for the Open System (유닛 모듈라 주택의 설계자동화를 위한 기초 연구(I) - 부품 및 유닛의 DB설정을 중심으로-)

  • Lim, Seok-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.287-290
    • /
    • 2005
  • Precast Concrete apartments were main stream of domestic industrialized housing around 90's , and Steel Houses applying Steel Stud technique with light weighted steel have been dominant portion since 1995. On the other hand, various building techniques including Steel Stud method and highly prefabricated and industrialized Unit method are prevailing in developed countries like Japan. Steel stud and Unit Box have their own merits an demerits, but the more crucial aspect is that the constant design standard should be applied in each design procedure. It entails the necessity of industrial housing development on the Open System basis. In this study, the design standard for Unit house will be established coping with the established preparing standard for design specifications defined by Architectural Law and Promotion Law of Housing Construction. That is for design standard of industrialized private housing on the Open System basis.

  • PDF

A Study on the Design criteria of Steel Unit House for the Open System (유닛 모듈라 주택의 설계자동화를 위한 기초 연구(II) - 유닛간의 결합/배치/평면구성 원칙을 중심으로-)

  • Lim, Seok-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.291-294
    • /
    • 2005
  • Precast Concrete apartments were main stream of domestic industrialized housing around 90's , and Steel Houses applying Steel Stud technique with light weighted steel have been dominant portion since 1995. On the other hand, various building techniques including Steel Stud method and highly prefabricated and industrialized Unit method are prevailing in developed countries like Japan. Steel Stud and Unit Box have their own merits and demerits, but the more crucial aspect is that the constant design standard should be applied in each design procedure. It entails the necessity of industrial housing development on the Open System basis. In this study, the design standard for Unit house will be established coping with the established preparing standard for design specifications defined by Architectural Law and Promotion Law of Housing Construction. That is for design standard of industrialized private housing on the Open System basis.

  • PDF

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique (구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용)

  • 김규식;진심원;정인화;이정우;강연준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

Development of logical structure for multi-unit probabilistic safety assessment

  • Lim, Ho-Gon;Kim, Dong-San;Han, Sang Hoon;Yang, Joon Eon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1210-1216
    • /
    • 2018
  • Site or multi-unit (MU) risk assessment has been a major issue in the field of nuclear safety study since the Fukushima accident in 2011. There have been few methods or experiences for MU risk assessment because the Fukushima accident was the first real MU accident and before the accident, there was little expectation of the possibility that an MU accident will occur. In addition to the lack of experience of MU risk assessment, since an MU nuclear power plant site is usually very complex to analyze as a whole, it was considered that a systematic method such as probabilistic safety assessment (PSA) is difficult to apply to MU risk assessment. This paper proposes a new MU risk assessment methodology by using the conventional PSA methodology which is widely used in nuclear power plant risk assessment. The logical failure structure of a site with multiple units is suggested from the definition of site risk, and a decomposition method is applied to identify specific MU failure scenarios.

Unit-load Method for the Estimation of Non-point Pollution Loads by Subcategorizing the Land-use Category Reflected in the National Land Register Data : A Case Study of Kyeongan Watershed in South korea (경안천 유역 지적공부에 나타난 특정지목의 토지이용 특성 세분화를 통한 비점오염 부하량 산정 개선방안)

  • Lee, Bum-Yeon;Lee, Chang-Hee;Ha, Do;Lee, Su-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.598-607
    • /
    • 2010
  • One of constraints in the application of unit-load method to estimate non-point pollution loads in the total water pollutant load management system (TWPLMS) is the limited numbers of applicable unit-loads. Since only 7 unit-loads are currently available for total 28 land-use categories in the national land register data, each unit-loads inevitably have to represent several land-use categories regardless of their actual land coverage characteristics. As a way to minimize the problem, this study suggested a nested application of the available unit-loads based on the analysis of high resolution aerial images taken in the Kyeongan watershed. Statistical analysis of three selected land-use categories such as school, apartment complex, and golf course showed that there exit significant (95% confidence level) relationships between the registered land-uses and actual land coverages. The school and apartment complex currently considered as 100% ground have only 65% and 80% of ground characteristics, respectively. Golf course, which is considered as 100% pasture, has about 5% of ground area. This indicates that the unit-load method using in TWPLMS can give over estimated non-point pollutant loads for the school and apartment complex (19.8~54.4%) but under estimation for the golf course (80.9%).

A Study on Robust Design of PCB for Package on Package by Numerical Analysis with Unit and Substrate Level to Reduce Warpage (수치해석을 이용한 Package on Package용 PCB의 Warpage 감소를 위한 Unit과 Substrate 레벨의 강건설계 연구)

  • Cho, Seunghyun;Kim, Yun Tae;Ko, Young Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.31-39
    • /
    • 2021
  • In this paper, warpage analysis that separates PCB for PoP (Package on Package) into unit and substrate using FEM (Finite Element Method), analysis of the effect of layer thickness on warpage, and SN (Signal-to-Noise) ratio by Taguchi method was carried. According to the analysis result, the contribution of the circuit layer on warpage was very high in the unit PCB, and the contribution of the outer layer was particularly high. On the other hand, the substrate PCB had a high influence of the circuit layer on warpage, but it was relatively low compared to the unit PCB, and the influence of the solder resist was rather increased. Therefore, considering the unit PCB and the substrate PCB at the same time, it is desirable to design the PCB for PoP layer-by-layer structure so that the outer and inner circuit layers are thick, the top solder resist is thin, and the thickness of the bottom solder resist is between 5 ㎛ and 25 ㎛.