• Title/Summary/Keyword: Unit area load

Search Result 214, Processing Time 0.036 seconds

Unit Loads of Pollutants in a Paddy Fields Area with Large-Scaled Plots during Irrigation Seasons (관개기 대구획 광역논에서의 오염부하 원단위)

  • 오승영;김진수;김규성;김선종;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.136-147
    • /
    • 2002
  • Characteristics of unit loads of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of 1999 ∼2000. The average irrigation requirement of experimental paddy area are estimated at over 3,000 mm. The unit loads of pollutants in paddy fields area are determined by subtracting irrigation water load from outflow load (percolated and surface outflow loads). Surface outflow load in rainy days was calculated using the relationships of discharge and load, which are grouped into fertilizing and non-fertilizing periods. The ratios of the surface outflow load in rainy days to the total surface outflow load are 16.4% for T-N, 26.8% for T-P, and 23.3% far CODc,. The unit loads of pollutants show month-to-month and year-to-year variations, and monthly unit load of pollutants can show negative values, indicating that the paddy area acts as the pollutants sink. The average unit loads of the pollutants during irrigation seasons were estimated at 18.2 kg/ha fur T-N, 0.31 kg/ha for T-P, and 43.3 kg/ha for CODc,, which are smaller than the reported values for Kosei area in Japan.

The Calculation of NPS Load per Unit Area in Orchard to the Nakdong River Basin (낙동강유역 과수재배지의 단위면적당 비점오염부하량 산정에 관한 연구)

  • Lee, Jae-Woon;Kwon, Heon-Gak;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.557-568
    • /
    • 2013
  • In this study, Calculated the nonpoint sources(NPS) load per unit area about various rainy events in vineyard of Nakdong River basin. NPS monitoring and calculation for NPS load per unit area were estimated from 'Investigation method of precipitation discharge(National Institute of Environmental Research, 2007)'. The evaluation of applicability for NPS load per unit by compared with prior research data and Total Maximum Daily Load(TMDL) data. Five target areas were each $2000m^2$, $1800m^2$, $1943m^2$, $2484m^2$, $864m^2$ and located in Gyeongsangbukdo Gyeongju, Gyeongsangbukdo Sangju, Gyeongsangnamdo Hapcheon in Korea. Since fruits were the only crop on the target area, the characteristics of stormwater discharge at survey sites could be evaluated independently. A total of 115 rainfall events in the Orchard area during five years(2008-2012) was surveyed, and 38 of them became stormwater discharge. In the Nakdong River watershed, average of event mean concentrations(EMCs) in Orchard area for biochemical oxyzen demand(BOD), Chemical oxyzen demand(COD), total nitrogen(T-N), total phosphorus(T-P) were 2.0mg/L, 10.1mg/L, 3.195mg/L, 0.578mg/L, respectively. NPS load per unit area in Orchard area showed BOD : $2.0kg/km^2{\cdot}day$, COD : $10.2kg/km^2{\cdot}day$, T-N : $3.220kg/km^2{\cdot}day$, T-P : $0.606kg/km^2{\cdot}day$.

A Study for the Selection Method of Control Area of Nonpoint Pollution Source (비점오염원 관리지역의 선정 기법에 관한 연구)

  • Park, Sanghyun;Jeong, Woohyeok;Yi, Sangjin;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Comparison of Estimation Method of Pollutant Unit Loads from Bridge Area (교량지역의 다양한 비점오염물질 원단위 산정방법 비교)

  • Kim, Taewon;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.597-604
    • /
    • 2011
  • This research analyzed the runoff patterns and estimated unit loads of selected pollutatnts using monitored data conducted for three years in a bridge area. Three estimating methods; the arithmetic average method, the regression method and the rainfall class method were used to estimate the unit load. Results of three estimating methods were compared with the unit pollutant loads from landuses in Korea and the unit pollutant loads from urban watersheds in Milwaukee, USA. Unit load using the arithmetic mean method were found to be overestimated. In terms of TSS, unit loads of two estimate were half lower than that of USA. Estimated TN and TP unit loads of three estimate were lower than that of Ministry of Environment in Korea.

Runoff of Pollutant Loads from Paddy Field Area in a Dry Year (갈수년 광역논에서의 오염부하의 유출 특성)

  • Oh, Seung-Young;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.385-388
    • /
    • 2002
  • We investigated net outflow load and unit load of pollutants from a paddy fields area in dry year 2001. Amount of irrigation water in 2001 was about 61-63% of that in previous years 1999 and 2000 due to drought. The net outflow load and unit load of pollutants in 2001 were negative, showing that paddy fields acts as sink of pollutants due to function of water quality purification. The relationship between unit load of pollutants and net surface outflow (= surface outflow - irrigation water) showed positive correlation. The results showed that abatement of surface outflow by appropriate water management contribute to reduce surface outflow load from paddy fields.

  • PDF

Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin (수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로)

  • Park, Jun Dae;Choi, Ok Youn;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

Neural Network Based Land Cover Classification Technique of Satellite Image for Pollutant Load Estimation (신경망 기반의 오염부하량 산정을 위한 위성영상 토지피복 분류기법)

  • Park, Sang-Young;Ha, Sung-Ryong
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.1-4
    • /
    • 2001
  • The classification performance of Artificial Neural Network (ANN) and RBF-NN was compared for Landsat TM image. The RBF-NN was validated for three unique landuse types (e.g. Mixed landuse area, Cultivated area, Urban area), different input band combinations and classification class. The bootstrap resampling technique was employed to estimate the confidence intervals and distribution for unit load, The pollutant generation was varied significantly according to the classification accuracy and percentile unit load applied. Especially in urban area, where mixed landuse is dominant, the difference of estimated pollutant load is largely varied.

  • PDF

Assessing unit load in farmland by application of liquid manure and organic farming (액비 및 유기농법 적용에 따른 농경지에서의 오염부하 원단위 평가)

  • So, Hyunchul;Jang, Taeil;Hong, Seung-Gil
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.39-48
    • /
    • 2017
  • National Institute of Environmental Research (NIER) has proposed new methodology for estimating unit load in order to overcome the limitations of past unit load based on short-term and local area based data. In the case of agricultural land, however, the results presented by NIER are still limited because of various agricultural activities and farmland characteristics. In this study, liquid manure treated paddy field and organic farming upland were selected for considering agricultural diversity. Four different methods for evaluating unit load were used for comparing previous research results. The results of different methods presented various trends compared with those of existing studies. Paddy field treated liquid manure was 1.3 times higher for T-N load and 3.1 times for T-P load than conventional paddy field. Conventional upland was 4.4 times higher for T-N load and 1.8 times higher for T-P load than organic farming upland. In the case of non-conventional farmland, this study showed different values with the unit loads presented by NIER. This implies that it is necessary to review and apply the unit loads considering various agricultural conditions when establishing environmental policy and rural planning.

Analysis of Changes in Land Use and Pollution Load for the Unit Watersheds of Total Maximum Daily Loads (총량관리 단위유역의 토지이용 변화 및 오염물질 배출형태 분석)

  • Park, Jun Dae;Oh, Seung Young;Choi, Ok Youn
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.128-137
    • /
    • 2014
  • The land use of the unit watersheds should be maintained appropriately in order to keep the load allotment stable for the management of Total Maximum Daily Loads (TMDLs). This study classified the land area in four types and analyzed the use of each land type and its changing pattern by calculating the occupation and conversion ratios for the unit watersheds in three river basins. The forest land showed the greatest occupation ratio with 63.0%, followed by the farm land with 23%, the other area with 8.0% and the site area with 6.0% in 2003. The occupation ratio of the site and the other area increased by 0.4% and 0.2% respectively, and that of the farm and the forest land decreased by 0.4% and 0.2% respectively in 2007. The conversion ratio for the site area ranged from 1.65% to 1.97%, for the farm land from -0.47% to -0.33%, for the forest land from -0.10% to -0.04% and for the other area from 0.17% to 1.97%. It can be inferred that the decrease in the farm and the forest land contributed to the increase in the site area and that the increase in the other area was mainly made by the decrease in the forest land. It could be more effective to take into account the changes in the site area and in the forest land in the process of developing the TMDL plans.