• 제목/요약/키워드: Unit Volume

검색결과 1,252건 처리시간 0.026초

고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR))

  • 이승엽;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

  • PDF

장기만연속수수량추정모형의 실용화 연구 -우리나라 중소유역을 대상으로- (A Generalized Model on the Estimation of the Long - term Run - off Volume - with Special Reference to small and Medium Sized Catchment Areas-)

  • 임병현
    • 한국농공학회지
    • /
    • 제32권4호
    • /
    • pp.27-43
    • /
    • 1990
  • This study aimed at developing a generalized model on the estimation of the long - term run - off volume for practical purpose. During the research period of last 3 years( 1986-1988), 3 types of estimation model on the long - term run - off volume(Effective rainfall model, unit hydrograph model and barne's model for dry season) had been developed by the author. In this study, through regressional analysis between determinant factors (bi of effective rainfall model, ai of unit hydrograph model and Wi of barne's model) and catchment characteris- tics(catchment area, distance round the catchment area, massing degree coefficient, river - exte- nsion, river - slope, river - density, infiltration of Watershed) of 11 test case areas by multiple regressional method, a new methodology on the derivation of determinant factors from catchment characteristics in the watershed areas having no hydrological station was developed. Therefore, in the resulting step, estimation equations on run - off volume for practical purpose of which input facor is only rainfall were developed. In the next stage, the derived equations were applied on the Kang - and Namgye - river catchment areas for checking of their goodness. The test results were as follows ; 1. In Kang - river area, average relative estimation errors of 72 hydrographs and of continuous daily run - off volume for 245 days( 1/5/1982 - 31/12) were calculated as 6.09%, 9.58% respectively. 2. In Namgye - river area, average relative estimation errors of 65 hydrographs and of conti- nuous daily run - off volume for 2fl days(5/4/1980-31/12) were 5.68%, 10.5% respectively. In both cases, relative estimation error was averaged as 7.96%, and so, the methodology in this study might be hetter organized than Kaziyama's formula when comparing with the relative error of the latter, 24~54%. However, two case studies cannot be the base materials enough for the full generalization of the model. So, in the future studies, many test case studies of this model should he carries out in the various catchment areas for making its generalization.

  • PDF

콘크리트 내 수량증감에 의한 내구 품질 변동에 관한 연구 (A Study on Durability Variation of Concrete due to Water Content Changes)

  • 우영제;류화성;정상화;권기준
    • 한국방재학회 논문집
    • /
    • 제7권2호통권25호
    • /
    • pp.1-6
    • /
    • 2007
  • 콘크리트내의 수량이 증가하면 내구성저하등에 다양한 문제점이 발생한다. 이러한 이유로 단위수량의 측정방법인 정전용량법, 고주파가열법, 단위용적질량법을 이용하여 단위수량의 변동을 관리하고 있다. 특히 일본에서는 단위수량 변동$({\pm}10,\;15,\;20kg/m^3$ 등)에 대한 관리지침을 규정하고 있다. 그러나 일본의 지침은 내구성 저하를 고려하지 않고 있으며, 제조오차와 측정오차를 확률적으로 고려하여 합부 판정기준 값을 정하고 있다. 이에 본 연구에서는 관리오차에 의한 가수 및 인위적인 가수 등에 의한 콘크리트 내의 수량 변화가 콘크리트의 내구성저하에 미치는 영향을 검토하고자 하였다.

Azide형 감광성수지의 합성과 특성에 관한 연구 (A Study on the Synthesis and Property of Azide Type Photosensitive Resin)

  • 조가람
    • 한국인쇄학회지
    • /
    • 제14권1호
    • /
    • pp.115-131
    • /
    • 1996
  • The PVT(pressure-volume-temperature) relation of main-chain dimer liquid crystals having structures such as $\alpha$,$\omega$-bis[(4,4`-cyanobiphenyl) oxy] alkane(CBA-n with=9, 10) were studied. these dimer liquid crystals are known to form an enantiotropic nematic mesophase. In this work, we have determined the volume change as a function of temperature and pressure by using a GNOMIX PVT apparatus. In the V-Tcurves obtaind from isobaris mearements on various pressures, volume changes were observed at the nematic-isotropiz and nematic-crystal phase transitions. The volume changes at the transition exhibit slight odd-even effect with respect to the number of methylene unit n. The values of the (S)v obtained at the NI transition for CBA-9 and -10 were 6.9 and 12.6J/mol k. The valuesof (S)v for the CN transition were estimated on the basis of DSC(differential scanning calorimetry) data: 58.8(CBA-9) and 65.3J/mol k (CBA-10). For both transition, it was found that the correction about the volume change is significant, ranging from 40% to 60% of the total transition entropy observed under constant pressure.

  • PDF

룰 베이스를 이용한 정풍량 공조기 고장 검출 및 진단 시스템의 실험적 연구 (An Experimental Study on the Rule Based Fault Detection and Diagnosis System for a Constant Air Volume Air Handling Unit)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.872-880
    • /
    • 2004
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, an air handling unit fault test apparatus was built and fault diagnosis algorithms were applied to diagnose various faults of an air handling unit. Test results showed the good diagnosis for applied faults. Therefore, these algorithms may be effectively used to develope the real time fault detection and diagnosis system for the air handling unit.

고강도 콘크리트의 단위수량 신속 측정기법별 배합요인에 따른 성능 검토에 관한 연구 (A Study on the Investigation of Performance about Quick Measurement Technology of Unit Water Content at Mixing Factor of High Strength Concrete)

  • 윤섭;정영민;정용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.745-748
    • /
    • 2008
  • On investigation about quick measurement technology of unit water at range of W/B=35% in high strength, the average error of the Di-electric constant moisture tester A has measured more than $23.0kg/m^3$ unit water content of design and the average error of the method of unit volume weigh was less than $-9.6kg/m^3$. The average error with mixing factor has influenced with a kind of sand, but had not influenced with unit water content of design. Therefore, it will be for introduce business decide require more than a study about cement, sand, superplasticizer, etc.

  • PDF

Safer Zone Analysis for Multiple Investment Alternatives on the Total-Cost Unit-Cost Domain

  • Kono, Hirokazu
    • Industrial Engineering and Management Systems
    • /
    • 제11권1호
    • /
    • pp.11-17
    • /
    • 2012
  • Along with the recent trend toward increasing variety and shorter life of products in the market, evaluation of risk for economic investment alternatives is of practical importance in manufacturing companies. This paper assumes that each alternative is composed of demand volume and unit sales price as income factors, and unit variable cost and fixed cost as expense factors. The paper assumes that these four factors move worse from the originally expected values, toward the direction of decreasing profit. Values of these four factors are also assumed to fluctuate from year to year over the entire multi-period. By applying the analysis of the breakeven points to each of the four factors, safer area against these changes is represented on the two dimensional domain called normalized total-cost unit-cost domain. A practical numerical example is analyzed to verify the validity of the proposed method.

발파석 굵은골재를 사용하는 콘크리트의 강도 발현 특성 (The Manifest Characteristics of Concrete that Uses Crushed Coarse Aggregate)

  • 이홍규;김상섭;송원루;박용준;이명호;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.132-133
    • /
    • 2015
  • In this research by examining the influence that low quality aggregate has on the strength of concrete through testing, the lowering of strength according to use of low quality coarse aggregate was reviewed. The results showed that when using low quality coarse aggregate, due to the quality of aggregate a high volume of units was required, and this caused the compression strength to be lowered. In conclusion it was confirmed that if the low quality aggregate was used as is without mix correction this would lead to faulty construction and if the aggregate was corrected to about 60 kg/m3 mix correction, this would lead to an economically infeasible concrete mix.

  • PDF

Twisted Yarn 복합재료의 탄성계수 예측모델 (Elastic Model of Twisted Yarn Composites)

  • 변준형;이상관;엄문광
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2002
  • The stiffness model has been proposed to predict elastic constants of twisted yarn composites. The model is based upon the unit cell structure, the coordinate transformation, and the volume averaging of compliance constants for constituent materials. For the correlation of analytic results with experiments, composite samples of various yarn twist angle were tested. The samples were fabricated by the RTM process using glass yarns and epoxy resin. The correlations of elastic constants showed relatively good agreements. The model provides the predictions of the three-dimensional engineering constants, which are valuable input data for the analytic characterization of textile composites made of twisted yarn.

  • PDF

열-전기 유사성을 이용한 복합재료의 열전도도 예측 (Effective Thermal Conductivities of Fiber-Reinforce Composites Using a Thermal-Electrical Analogy)

  • 조영준;강태진;윤재륜
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.81-84
    • /
    • 2002
  • An approach for predicting the effective thermal conductivities of fiber-reinforce composite has been developed based on a thermal-electrical analogy. The unit cell of the composite laminate is divided into regular volume elements and the material properties have been given to each element. By constructing the series-parallel thermal resistance network, the thermal conductivities of composite both in-plane and out-of-plane direction have been predicted. Graphite/Epoxy composite is used for a balanced plain-weave composite laminate. By comparing the predicted results and the previous works, good agreement has been found.

  • PDF