• Title/Summary/Keyword: Unit Test Area

Search Result 407, Processing Time 0.031 seconds

A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas- (제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로)

  • 엄병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

An Analysis of the Unit Plan Characteristics for the Apartments at Metropolitan Seoul Area in the Context of Space Syntax Model (아파트 단위주거 평면의 규모별 공간구성에 관한 기초 연구)

  • 이동원;오도엽
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2004
  • The purpose of this study is to analyze spatial configuration of the unit floor plan characteristics of the apartments built in Seoul Metropolitan area by using the Space Syntax methodology and finally to test the relationship between space in the unit floor plans. So the unit floor plans are analyzed using sector graphs from justified graph and computer programs based on the Space Syntax model and compared by size. The results are as follows; The sector graphs are summarized in 14 types. The total depth of spaces is not in proportion to the plan area. And the global and local integration and intelligibility are inversely proportional to the area. But in the case of largest areas(265$m^2$ and above), the integration and intelligibility increase.

Evaluation of spatial pressure distribution during ice-structure interaction using pressure indicating film

  • Kim, Hyunwook;Ulan-Kvitberg, Christopher;Daley, Claude
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.578-597
    • /
    • 2014
  • Understanding of 'spatial' pressure distribution is required to determine design loads on local structures, such as plating and framing. However, obtaining a practical 'spatial' pressure distribution is a hard task due to the sensitivity of the data acquisition frequency and resolution. High-resolution Pessure-Idicating Flm (PIF) was applied to obtain pressure distribution and pressure magnitude using stepped crushing method. Different types of PIF were stacked at each test to creating a pressure distribution plot at specific time steps. Two different concepts of plotting 'spatial' pressure-area curve was introduced and evaluated. Diverse unit pixel size was chosen to investigate the effect of the resolution in data analysis. Activated area was not significantly affected by unit pixel size; however, total force was highly sensitive.

Development and Application of Distributed Vehicle Control Unit in Bimodal Tram (바이모달트램용 분산형 차량감시제어장치 개발 및 적용)

  • Lee, Kang-Won;Cho, Hyun;Lee, Hu-Un;Mok, Jai-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2192-2193
    • /
    • 2011
  • VCU(Vehicle Control Unit) was developed to decrease the wire weight and make it easy to control the power of ECU in bimodal tram. VCU consists of CC(Central Computer), DU(Display Unit), TU(Terminal Unit) with PCB. CC is a main controller with progamming and DU displays the status with graphic symbols and letters. TU with PCB inputs and output the voltage controlled by CC. They communicate with CAN(Controller Area Network). VCU had been verified with software reliability verification test and environmental hardware test. This paper has shown the test results and application to bimodal tram.

  • PDF

Development of Bypass Unit for Ship Area Network Based on Legacy-line Communication (무배선 통신을 위한 선박 네트워크용 바이패스 장치 개발)

  • Jun, Ho-Ik;Kim, Hyun-Sik;Jung, Kyun Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.292-297
    • /
    • 2015
  • In this paper, we reported the bypass unit for ship area networks in order to detour the communication failure regions and poor communication links. The device was composed of three parts of circuits for power cut-off, protection, and coupling transformer. Since the coupling transformer exerts a dominant influence on the performance of the by-pass unit, we have tried to find the optimal magnetic core materials and its dimensions. The prototype was passed through the performance test of insertion loss, temperature, and vibration characteristics. The insertion loss was around -2 dB in the range of 90 kHz ~ 30 MHz and the average communication speed was 59.2 Mbps in the laboratory. A pilot communication test using the developed tool was conducted in the training ship of the Korea Maritime and Ocean University. As a results of experiment, we showed that the wired communication among the heterogeneous-links in the ship area networks are possible by the bypass unit and also a high speed communication services are available in ~ Mbps by using a power-line.

Reproducibility of Statistical Motor Unit Number Estimate in Amyotrophic Lateral Sclerosis: Comparisons between Size-and Number-Weighted Modifications (근위축성 측삭 경화증에서의 Statistical Motor Unit Number Estimate 재연성: Size-and Number-Weighted Modifications간의 비교)

  • Kwon, Oh Yun;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Background: Motor unit number estimation (MUNE) can directly assess motor neuron populations in muscle and quantify the degree of physiologic and/or pathologic motor neuron degeneration. A high degree of reproducibility and reliability is required from a good quantitative tool. MUNE, in various ways, is being increasingly applied clinically and statistical MUNE has several advantages over alternative techniques. Nevertheless, the optimal method of applying statistical MUNE to improve reproducibility has not been established. Methods: We performed statistical MUNE by selecting the most compensated compound muscle action potential (CMAP) area as a test area and modified the results obtained by weighted mean surface-recorded motor unit potential (SMUP). Results: MUNE measures in amyotrophic lateral sclerosis (ALS) patients showed better reproducibility with sizeweighted modification. Conclusions: We suggest size-weighted MUNE testing of "neurogenically compensated"CMAP areas present an optimal method for statistical MUNE in ALS patients.

  • PDF

A High-Frequency Signal Test Method for Embedded CMOS Op-amps

  • Kim Kang Chul;Han Seok Bung
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.1
    • /
    • pp.28-32
    • /
    • 2005
  • In this paper, we propose a novel test method to effectively detect hard and soft faults in CMOS 2-stage op-amps. The proposed method uses a very high frequency sinusoidal signal that exceeds unit gain bandwidth to maximize the fault effects. Since the proposed test method doesn't require any complex algorithms to generate the test pattern and uses only a single test pattern to detect all target faults, therefore test costs can be much reduced. The area overhead is also very small because the CUT is converted to a unit gain amplifier. Using HSPICE simulation, the results indicated a high degree of fault coverage for hard and soft faults in CMOS 2-stage op-amps. To verify this proposed method, we fabricated a CMOS op-amp that contained various short and open faults through the Hyundai 0.65-um 2-poly 2-metal CMOS process. Experimental results for the fabricated chip have shown that the proposed test method can effectively detect hard and soft faults in CMOS op-amps.

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

A Study of Nurses' Knowledges on Gestational Diabetes Mellitus (일부 간호사의 임신성 당뇨병에 대한 지식정도)

  • Choi, Euy-Soon;Oh, Jeong-Ah;Park, Chai-Soon
    • Women's Health Nursing
    • /
    • v.7 no.4
    • /
    • pp.419-431
    • /
    • 2001
  • The purpose of this study was to provide the correct knowledge on GDM(Gestational Diabetes Mellitus) to nurses for effective care of pregnant women with GDM by investigating the knowledge of nurses about GDM. The subjects of this study were 557 nurses who work at six general hospitals in Seoul and Gyung-Gi province of Korea. The data were collected from November, 2000 to December, 2000, using a 30-item knowledge questionnaire about GDM consisted of eight areas developed by Choi et al. (2000): characteristics and diagnosis, influence on pregnancy, goal and method of management, diet therapy, exercise therapy, insulin therapy, hypoglycemia and hyperglycemia and postpartum care of GDM. The data were analyzed by SAS program for t-test, ANOVA and Scheffe test. The results were as follows: 1. The mean score of knowledge on GDM was 23.18. 2. There were significant differences according to age(p= 0.002), education background (p= 0.045). working period(p= 0.000), working unit(p= 0000), working experience of obstetric and gynecologic (OS & GY) units(p= 0.000), experience of pregnancy (p=0.003) and experience of delivery (p=0.014) in GDM knowledge. 3. The level of each area on GDM knowledge was as follows; 1) Area of characteristics and diagnosis of GDM The mean score of this area was 0.79. Nurses' knowledges were significantly different by age(p=0.003), marital status (p=0.018), working period(p=0.002) working unit(p=0.007), working experience of OB & GY units(p=0.005), experience of pregnancy(p=0.034) and experience of delivery(p=0.033). 2) Area of influence on pregnancy The mean score of this area was 0.93. Nurses' knowledges were significantly different by age(p=0.006), working unit (p=0.000) and working experience of OB & GY units(p= 0.000). 3) Area of goal and method of management The mean score of this area was 0.70. Nurses' knowledges were significantly different by age(p=0.004), region(p=0.006), education background(p=0.013), marital status(p=0.007), working period(p=0.000), working unit(p=0.011), working experience of OB & GY units(p=0.002), experience of pregnancy(p=0.025) and experience of delivery(p=0.043). 4) Area of diet therapy. The mean score of this area was 0.74. Nurses' knowledges were significantly different by age(p=0.002), region(p=0.011), marital status (p=0.001). working period (p=0.007). working unit(p=0.002), working experience of OB & GY units(p=0.001), experience of pregnancy(p=0.001), experience of delivery(p=0.011) and diabetes patients in family members(p=0.032). 5) Area of exercise therapy. The mean score of this area was 0.83. There were not significant differences in all general characteristics. 6) Area of insulin therapy The mean score of this area was 0.61. Nurses' knowledges were significant differences by age (p=0.024), marital status (p=0.048), working period(p=0.027), working unit(p=0.002), working experience of OB & GY units(p=0.000), experience of pregnancy (p=0.047) and experience of delivery(p=0.040). 7) Area of hypoglycemia and hyperglycemia. The mean score of this area was 0.83. Nurses' knowledges were significantly different by marital status (p=0.027), working period(p=0.001). experience of pregnancy(p=0.020) and experience of delivery(p=0.010). 8) Area of postpartum care The mean score of this area was 0.69. Nurses' knowledges were significantly different by working unit(p=0.000), working experience of OB & GY units (p=0.000) and working experience of medical unit(p=0.047). The results of this study are suggested that nurses might be taught systemically and individually about GDM so that they can become more proficient in detecting and preventing GDM, and therefore they will feel confident to teach GDM to women.

  • PDF

Effect of the Mold Temperatures on the Microstructure and Mechanical Properties of Low Pressure Die-Cast Product (저압주조품의 미세조직과 기계적성질에 미치는 금형온도의 영향)

  • Lee, Jeong-Keun;Park, Chong-Sung;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.18 no.3
    • /
    • pp.254-261
    • /
    • 1998
  • Microstructure and mechanical properties of the low pressure die-cast Al wheels were investigated by microscope, image analyzer, NDT (non-destructive test), and tensile test. The variation of SDAS (secondary dendrite arm spacing), porosity per unit area, quality grade, and tensile properties with the mold temperatures were examined. SDAS was gradually decreased with a decrease in temperature. However, the lowest value of porosity per unit area was observed at the mold temperature of $405^{\circ}C$ and the optimum mold temperature was found to be $405^{\circ}C$. Besides, from the observation of pore morphology, it was also found that the pore formation was mainly caused by shrinkage during solidification. The tensile strength, elongation, and impact toughness were markedly decreased, however the yield strength was nearly constant. The decrease of mechanical properties is attributed to the increase of porosity.

  • PDF