• Title/Summary/Keyword: Unit Power Factor

Search Result 252, Processing Time 0.027 seconds

Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup (초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가)

  • Kang Sung-Mook;Lee Jin-Eui;Cho Eun-Hyoung;Sohn Jin-Seung;Park No-Cheol;Park Young-Pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.154-159
    • /
    • 2005
  • The next generation of optical storage systems requires higher numerical aperture (NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error awe performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated, the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

Study on Resistance Component of Container Ship According to Trim Conditions (트림 변화에 따른 컨테이너선의 저항성분별 특성 연구)

  • Han, Ki-Min;Park, Hyun-Suk;Seo, Dae-Won
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.411-417
    • /
    • 2015
  • The shipping and shipbuilding industries have had business difficulties since the implementation of regulations on the CO2 emissions from ships by IMO and the occurrence of the global financial crisis in 2008. Under this global recession, most shipping firms have started to operate their fleets at slow steaming rates with the goal of improving the profit ratio per transported unit. This study analyzed the resistance performance of a 6,800 TEU container ship corresponding to its trim variation with slow steaming, compared with that at its original design speed. Two different grid systems were used for the numerical calculation, one that considered the free surface allowing the capture of the dynamic trim and one that did not. This made it possible to clearly classify each resistance component to provide useful information to hull-form designers. In addition, a form factor assumption method using CFD was used for a reasonable effective power prediction in compliance with the 1978 ITTC performance prediction method. It was found that the total resistance of a 6,800 TEU container ship was reduced by 2.6% in the case of a 1-m trim at the bow at 18 kn.

Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup (초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가)

  • Kang, Sung-Mook;Lee, Jin-Eui;Cho, Eun-Hyoung;Sohn, Jin-Seung;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.79-84
    • /
    • 2006
  • The next generation of optical storage systems requires higher numerical aperture(NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error are performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated. the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

The Study on the Standardization of the Maximum Acceleration of the Electric Multiple Unit through the Analysis of the Traction and the Adhesion Characteristics (견인력 및 점착력 특성 분석을 통한 전동차 최대 가속도 규격 선정에 관한 연구)

  • Kim, Jungtai;Kim, Moo Sun;Ko, Kyeongjun;Jang, Dong Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7934-7940
    • /
    • 2015
  • The raise of the acceleration can be one of possible methods to increase the scheduled speed of the metropolitan railway system. It is possible to raise the acceleration to the some point by increasing the traction power of the motor. However, there is a limit of the acceleration because the traction power over some level related to the adhesion causes a slip, which prevents from accomplishing the target acceleration. The running resistance is also an important factor to consider. Both the adhesion and the running resistance as well as the traction power vary according to the velocity. Therefore, the standardization of the acceleration needs the analysis of these factors as a function of velocity. In this study, we focus on the advanced urban transit unit(AUTS) for the standardization. We derive a novel equation of the adhesion suitable for the AUTS by investigation of the traction and adhesion equation as well as the experiment data. And finally we propose the standard of the acceleration based on this analysis.

Design of off-line UPS with AVR (AVR 기능 부가 off-line UPS 설계)

  • Lee, Seung-Hee;Park, Tae-Jun;Lee, Jin-Hee;Lee, Wang-Ha;Lee, Chi-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.605-607
    • /
    • 2001
  • In this paper, an off-tine UPS with CVT(constant voltage transformer) is designed and the experimental result and problems of the designed UPS is given and discussed. This off-line UPS consists of triple-port CVT and PWM inverter which acts as charger and inverter. It can be evaluated in low price because haying simple structure. It offers high performance because CVT restricts the short current automatically about two or three times of rated current, has nearly unit power factor and constant output voltage to varying input voltage. The weak points of this UPS are that the output voltage waveform is not perfect sinusoidal and has phase difference to input voltage. The experimental result and problems of the designed UPS is given.

  • PDF

Temperature Coefficient in D$_2$O Moderated Reactor(Wolsung Unit 1)

  • Suh, Soo-Hyun;Chang, Yo-Han;Kim, Seong yun;Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.125-137
    • /
    • 1977
  • The temperature coefficient has been investigated on the Wolsung nuclear power reactor, in which fuel is natural uranium dioxide and moderator heavy water. The numerical computations are carried out in terms of changes of the effective neutron multiplication factor with respect to fuel, moderator, and coolant temperatures. Those results are compared with the computed values of temperature coefficient based on the LATREP computer code.

  • PDF

Fatigue Evaluation on the Inside Surface of Reactor Coolant Pump Casing Weld

  • Kim, Seung-Tae;Park, Ki-Sung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.795-801
    • /
    • 1998
  • Metallic fatigue of Pressurized Water Reactor(PWR) materials is a generic safety issue for commercial nuclear power plants. It is very important to obtain the fatigue usage factor for component integrity and life extension. In this paper, fatigue usage was obtained at the inside surface of Kori unit 2, 3 and 4 RCP casing weld, based on the design transient. And it was intended to establish the procedure and the detailed method of fatigue evaluation in accordance with ASME Section III Code. According to this code rule, two methods to determine the stress cycle and the number of cycles could be applied. One method is the superposition of cycles of various design transients and the other is based on the assumption that a stress cycle correspond to only one design transient. Both method showed almost same fatigue usage in the RCP casing weld.

  • PDF

Linearized Optimal PWM Techniques for Current Source GTO Converter (전류형 GTO 컨버터의 최적제어 PWM 선형화기법)

  • Pang, Sung-Il;Chae, Kyoung-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.426-428
    • /
    • 1997
  • This paper presents the linearized optimal PWM techniques for current source GTO converter. This proposed method is to linearize an optimal PWM modulation strategy so that the turn-on/off-periods of the GTO switches can be computed on-line in real-time for any modulation index. This allows the rapid and continuous regulation of the DC output current while producing the sinusoidal AC input current waveform and unit power factor.

  • PDF

A Study on High Efficiency Electronic Ballast for Metal Halide Discharge Lamps (메탈핼라이드 램프용 고효율 전자식 안정기에 관한 연구)

  • Kim, Hae-Jun;Won, Jae-Sun;Park, Jae-Wook;Seo, Cheol-Sik;Lee, Seung-Hee;Sim, Kwang-Yeal;Kim, Jong-Hae;Kim, Dong-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2157-2165
    • /
    • 2007
  • A novel design technology for a high frequency electronic ballast for metal-halide discharge lamps is proposed. A PFC technique is adopted to get unit power factor and output frequency alteration technique is adopted to avoid acoustic resonance. For characteristics evaluation, the designed electronic ballast is presented using normalized parameter. To reduce losses of the ballast. ZVS control technique is adopted and the maximum flux density of magnetic core for inductor should be kept lower. The electronic ballast for 250[W] metal-halide discharge lamp is implemented and 96[%] efficiency and low conducted EMI level are accomplished.

A Study on the Coolant Mixing Phenomena in the Reactor Lower Plenum

  • Park, Yong-Seog;Park, Goon-Cherl;Um, Kil-Sup
    • Nuclear Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.186-195
    • /
    • 1997
  • When asymmetric thermal-hydraulic conditions occur between cold legs, the core inlet temperature will be nonuniform if the coolant is not mixed perfectly in the lower plenum. These uneven core inlet conditions may induce the change in core power distribution. Thus realistic prediction of thermal mixing is important in such abnormal conditions. In this study, reactor internals, which are scaled down as to conserve the flow area ratio, are set up in the model of KORI Unit 1 with the scaling factor of 1/710 by volume and coolant temperatures are measured beneath the lower core plate. Based on experimental results, the ability of COMMIX-1B code to simulate the coolant mixing phenomena in the lower plenum is estimated. The results show that complete mixing never occurs in any conditions and the mixing pattern is characterized according to the plant type.

  • PDF