• Title/Summary/Keyword: Unit Load Method

Search Result 511, Processing Time 0.023 seconds

Development of an Artificial Neural Network Model for a Predictive Control of Cooling Systems (건물 냉방시스템의 예측제어를 위한 인공신경망 모델 개발)

  • Kang, In-Sung;Yang, Young-Kwon;Lee, Hyo-Eun;Park, Jin-Chul;Moon, Jin-Woo
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: This study aimed at developing an Artificial Neural Network (ANN) model for predicting the amount of cooling energy consumption of the variable refrigerant flow (VRF) cooling system by the different set-points of the control variables, such as supply air temperature of air handling unit (AHU), condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. Applying the predicted results for the different set-points, the control algorithm, which embedded the ANN model, will determine the most energy efficient control strategy. Method: The ANN model was developed and tested its prediction accuracy by using matrix laboratory (MATLAB) and its neural network toolbox. The field data sets were collected for the model training and performance evaluation. For completing the prediction model, three major steps were conducted - i) initial model development including input variable selection, ii) model optimization, and iii) performance evaluation. Result: Eight meaningful input variables were selected in the initial model development such as outdoor temperature, outdoor humidity, indoor temperature, cooling load of the previous cycle, supply air temperature of AHU, condenser fluid temperature, condenser fluid pressure, and refrigerant evaporation temperature. The initial model was optimized to have 2 hidden layers with 15 hidden neurons each, 0.3 learning rate, and 0.3 momentum. The optimized model proved its prediction accuracy with stable prediction results.

Parallel Optimal Power Flow Using PC Clustering (PC 클러스터링을 이용한 병렬 최적조류계산에 관한 연구)

  • Kim, Cheol-Hong;Mun, Kyeong-Jun;Kim, Hyung-Su;Park, J.H.;Kim, Jin-Ho;Lee, Hwa-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.190-193
    • /
    • 2004
  • Optimal Power Flow (OPF) is becoming more and more important in the deregulation environment of power pool and there is an urgent need of faster solution technique for on-line application. So this paper presents parallel genetic algorithm-tap search for the solution of the OPF. The control variables modeled unit active power outputs, generator-bus voltage magnitudes and transformer-tap settings. A number of functional operating constraints, such as branch flow limits, load bus boltage magnitude limits and generator reactive capabilities are included as penalties in the fitness function. In parallel GA-TS, GA operators are executed for each process. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper three populations to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the usefulness of the proposed method, developed algorithm has been tested and compared on an IEEE 30-bus system in the reference paper. From the simulation results, we can find that the proposed algorithm is efficient for the OPF.

  • PDF

An Efficient Distributed Shared Memory System for Parallel GIS (병렬 GIS를 위한 효율적인 분산공유메모리 시스템)

  • Jeong, Sang-Hwa;Ryu, Gwang-Yeol;Go, Yun-Yeong;Gwak, Min-Seok
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.5 no.6
    • /
    • pp.700-707
    • /
    • 1999
  • 본 논문에서는 GIS 관련 연산을 실시간에 효율적으로 처리하기 위한 분산공유메모리 기반 병렬처리 시스템을 제안한다. 본 논문의 분산공유메모리 시스템은 메시지전달 방식의 분산메모리 MIMD 컴퓨터 상에 소프트웨어 기반 분산공유메모리 모듈을 탑재함으로써 구현되었다. 또한 GIS 연산의 기본이 되는 공간 객체를 공유의 기본 단위로 설정하고, GIS 데이타의 특성을 반영하여 읽기전용 공유데이타 타입을 추가하였으며, 네트워크 오버헤드를 줄이기 위하여 복수의 객체를 한번에 읽어오는 bulk access가 가능하도록 하였다. 본 시스템에서는 GIS 데이타의 효율적인 분배를 위하여 부하균등화 기법으로 guided self scheduling을 사용하였다. 실험결과 본 시스템은 네트워크 캐쉬의 효율적인 활용을 통하여 소프트웨어 기반 분산메모리 시스템의 오버헤드에도 불구하고 MPI 기반 메시지전달 방식에 비하여 향상된 성능을 얻을 수 있었다.Abstract In this paper, we propose a distributed shared memory(DSM) based parallel processing system to process GIS related computations efficiently in real time. The system is based on a software DSM module implemented on top of a distributed MIMD computer. In the DSM system, spatial object, which is a fundamental structure to represent GIS data, is used as a basic unit for sharing, and a read-only shared data type is added to reflect the characteristics of GIS data. In addition, a bulk access to multiple shared data is made possible to reduce the network overhead. A guided self scheduling method is devised for efficient load balancing in distributing GIS data to parallel processors. The experimental results show that the DSM system performs better than an MPI based message-passing system through the efficient utilization of network cache in spite of the system's software overhead.

Quality Control of Majoon-e-Nisyan and its Acute Oral Toxicity Study in Experimental Rats

  • Shaikh, Masud;Husain, Gulam M.;Naikodi, Mohammed Abdul Rasheed;Kazmi, Munawwar H.;Viquar, Uzma
    • CELLMED
    • /
    • v.11 no.1
    • /
    • pp.2.1-2.8
    • /
    • 2021
  • The clinical condition Amnesia causes difficulty in learning new information and the inability to recall past events. It is primarily concerned with recent memory loss. Majoon-e-Nisyan (MJN) is a polyherbal Unani formulation, present in a semi-solid form. It is widely used potent drug of the Unani System of Medicine (USM) for treating Nisyan (amnesia). In the present study polyherbal Unani formulation, MJN has been studied for its quality control and acute toxicity. Standardization (quality control) of drugs deals with drug identity, drug quality and purity determination. Standardization of MJN had been done as per the Unani pharmacopoeial parameters approved by World Health Organization (WHO) - Pharmacognostical parameters, Physico-chemical parameters, high-performance thin-layer chromatography (HPTLC), microbial load, aflatoxin, and heavy metals. Solvents and chemicals used in the study were of analytical grade and used instrument were calibrated. By conducting an acute oral toxicity study in rats, the safety of MJN was assessed. The limit test method of OECD guideline 425 was followed in the study. Results of standardization and standard operating procedures (SOPs) for preparation of MJN may serve as the standard reference in the future. The data generated in the study for the quality control of MJN proved the quality of formulation and shows that MJN is not toxic in rats following acute dosing up to 2000 mg/kg bw. The data obtained in the paper for MJN may be used as a standard guideline for preparation of the formulation which can save time, cost, and resources for future research endeavours.

Analysis of Operation Areas for Automatically Tuning Burst Size-based Loss Differentiation Scheme Suitable for Transferring High Resolution Medical Data (고해상도 의학 데이터 전송에 적합한 자동 제어 버스트 크기 기반 손실 차등화 기법을 위한 동작 영역 분석)

  • Lee, Yonggyu
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.459-468
    • /
    • 2022
  • In medical area, very high resolution images, which is loss sensitive data, are used. Therefore, the use of optical internet with high bandwidth and the transmission of high realiability is required. However, according to the nature of the Internet, various data use the same bandwidth and a new scheme is needed to differentiate effectively these data. In order to achieve the differentiation, optical delay line buffers are used. However, these buffers is constructed based on some optimal values such as the average offered load, measured data burst length, and basic delay unit. Once the buffers are installed, they are impossible to reinstall new buffers. So, the scheme changing burst length dynamically was considered. However, this method is highly unstable. Therefore, in this article, in order to guarantee the stable operation of the scheme, the analysis of operation conditions is performed. With the analysis together with the scheme, high resolution medical data with the higher class can transmit stably without loss.

Preparation of Uniform Porous Carbon from Mesophase Pitch and Its Characteristics of Catalyst Support for the Direct Methanol Fuel Cell (메조페이스 핏치로부터 균질한 다공성 탄소 제조 및 이를 이용한 직접 메탄올 연료전지의 촉매 담지체 특성)

  • Nam, Ki-Don;Kim, Tae-Jin;Kim, Sang-Kyung;Lee, Byoung-Rok;Peck, Dong-Hyun;Ryu, Seung-Kon;Jung, Doo-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.17 no.2
    • /
    • pp.223-228
    • /
    • 2006
  • Pore-size controlled porous carbons for the catalyst supports of the direct methanol fuel cell were prepared from the mesophase pitch by using the silica spheres with different sizes. Pitch solution in THF and spheres were mixed, carbonized and etched by 5 M NaOH to make porous carbon. Specific surface area of the porous carbons was $14.7{\sim}87.7m^2/g$ and average pore diameter was 50~550 nm which were dependent on the size of silica spheres. Aqueous reduction method was used to load 60 wt% PtRu on the prepared porous carbon supports. The electro-oxidation activity of the supported 60 wt% Pt-Ru catalysts was measured by cyclic voltammetry and unit cell test. For the 60 wt% Pt-Ru/porous carbon synthesized by 50 nm silica, current density value in the cyclic voltammetry test was $123mA/cm^2$ at 0.4 V and peak power density in the unit cell test were 105 and $162mW/cm^2$ under oxygen at 60 and $80^{\circ}C$, respectively.

Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir - (농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 -)

  • Kim, Jin-Ho;Han, Kuk-Heon;Ryu, Jong-Soo;Jung, Goo-Bok;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.

A Study on the Characteristics of Wastewater Treatment by Rapid Infiltration Using Sand Soil (사토(砂土)를 이용(利用)한 급속토양삼투법(急速土壤滲透法)의 폐수처리(廢水處理) 특성(特性)에 관한 연구(研究))

  • Yang, Sang Hyon;Cho, Woong Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.23-31
    • /
    • 1987
  • In land treatment systems for organic waste removal, especially rapid intiltration method is well known as less climatic restrictions and less field area requirements as against the others. Therefore the present study on rapid infiltration is aimed to survey the waste removal rate, infiltration rate, variation of dissolved oxygen due to biological oxygen absorption and pH decrement using pilot infiltration column filled with permeable soil(sand) as media, also to find the waste load(COD) per unit area and nitrate conversion ratio from TKN. The results obtained here are as follows. 1) When the depth of sand layer is more than 1 meter, the COD removal would be reached steadly to 90% or more under the infiltration rate below 15~20cm/day, and would be no problem due to leached organic pollutants considering the depth of ground water table. 2) The COD removal per unit area($m^2$) can readily be expected to 10~14g/day with proper operation, and the decomposition of substrate would be attained mostly at the surface layer of the media. 3) Generally the conversion of TKN to the $NO_3{^-}$-N is seemed to be proportional to the COD removal rate if provided proper retention time.

  • PDF

Study on Development of Automated System for Hazard Screening at Analysis (위험 선별 및 분석 통합 자동화 시스템 개발에 대한 연구)

  • 한의진;김용하;최승준;김구회;윤인섭
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.20-27
    • /
    • 2003
  • Hazard Analysis is one of the basic tasks to ensure the safety of chemical plants. However, it is an arduous, tedious, time-consuming work and requires multidisciplinary knowledge and demands considerable cognitive load from the analysts. To overcome these problems, there have been attempts to automate this work by utilizing computer technology, particularly in the area of knowledge-based technique. There is two methods in the risk assessment of Chemical plant; quantitative and qualitative risk assessment. Both of them have been applied respectively, but if the integrated method of quantitative and qualitative risk assessments is used, all of the advantage of two methods can be applied. It is difficult to carry out integrated risk management of chemical plant. Therefore, automated integration system of risk management is necessary. We developed S/W Automated System for Hazard Screening & Analysis(ASCA) and applied to practical plant. By applying ASCA to case study, we can get the information about relative ranks of equipments, variable deviation, and consequence of potential accident. In this study, we applied ASCA to the H.T.U(Hydrotreating Unit) of the process to produce aromatic material. We could know relative ranks of equipments, variable deviation of malfunction in storage tank, D-101, and consequence of potential accident using ASCA. If integrated risk management in the chemical plant is applied, we can develop the emergency plan and prevent the accident.

Flexible Unit Floor Plan of Off-Site Construction Housing Considering Long-Lasting Housing Certification System (장수명주택 인증을 고려한 OSC공법 주택의 가변형 평면계획 연구)

  • Lee, Ji-Eun;Roh, Jeong-Yeol;Kwon, Soo-Hye;Kim, Seung-Mo
    • Land and Housing Review
    • /
    • v.12 no.4
    • /
    • pp.103-117
    • /
    • 2021
  • With the current rapid changes in population and technology, the long-lastig housing certification system is a means of prolonging the physical and functional lifespan of a building. The certification requires differentiation between the structure and infill elements to allow for variability and ease of repairs. This works well with prefabricated houses so this study investigated the possibility of applying the long-lastig housing certification requirements to apartment construction using off-site construction (OSC) methods focused on the installation of bathrooms (plumbing and toilet) that differ from the traditional wet method. This study examined three different sized floor plans at 22 m2, 46 m2, and a combined one resulting in 69 m2. The larger 69 m2 plan utilized a removeable non-load bearing wall to increase flexibility in the layout of the floorplan. The apartments are constructed of steel reinforced concrete composite columns on a 9 m × 10.5 m grid with integrated slabs. The exterior and interior infill walls are all non-load bearing with some containing plumbing. This separation of the structure and infill walls can help meet some of the criteria in the long-lastig housing certification, particularly with the ease of repairs. Technologies that facilitate the replacement of infill elements that contain plumbing and other building services can benefit the nation by reducing carbon emissions and therefore tax incentives should be introduced to increase the adoption of the proposed construction methods.