• 제목/요약/키워드: Unit Energy Production

검색결과 236건 처리시간 0.025초

Fuel Cost Analysis of CANDU-PHWR Wolsung Nuclear Power Plant Unit 1

  • Lee, Ik-Hwan;Lee, Chang-Kun;Yang, Chang-Guk;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.151-163
    • /
    • 1977
  • CANDU-PHWR형 원자로인 월성 1호기의 Zircaloy-4 피복 핵연료 설계치를 중심으로 Segel method에 의하며 FACOM 230 OS$_2$/VS 콤퓨터 시스템을 사용하여 핵연료비를 계산하였다. 아울러 핵연료 제조공장의 수덩, 가동을, 곧장시설 낑산규모 증대, 건설지 및 운전비기 변동, 이자율의 변화, 원광가격의 물가상승을, 기술개발인자 등이 핵연료비 계산에 미치는 효과에 패한 민감도를 분석하였다.

  • PDF

국내 열병합발전사업의 기술적 생산효율성 추정 및 사업구조 평가: 16개 집단에너지사업자에 대한 패널 확률프론티어모형(SFA) 분석 (Evaluation of Technical Production Efficiency and Business Structure of Domestic Combined Heat and Power (CHP) Operators: Panel Stochastic Frontier Model Analysis for 16 Collective Energy Operators)

  • 임형우;김재혁;신동현
    • 자원ㆍ환경경제연구
    • /
    • 제30권4호
    • /
    • pp.557-579
    • /
    • 2021
  • 집단에너지는 에너지전환의 중간단계이자, 분산전원으로서 전력구조에 미치는 영향이 크다. 하지만 최근 일부 집단에너지사업자의 수익성 악화로 인해 집단에너지사업의 문제가 대두되고 있다. 본 연구는 우리나라 집단에너지사업자의 기술적 생산효율성 추정을 통해, 주요 사업자의 기술적 생산효율성을 측정하였으며 이를 바탕으로 사업자의 수익구조 개선방안을 살펴보았다. 16개 집단에너지사업자의 2016~19년 세부 재무 및 생산 자료를 수집한 후, 패널 확률 프론티어모형을 이용하여 사업자들의 기술적 생산효율성을 추정하였다. 추정 결과, 증기공급병행, 대형 전기중심, 소규모 구역전기, 역송CHP 사업자 순으로 생산효율성이 높음을 확인하였다. 더 나아가 수익성 영향요인에 대해 살펴본 결과, 기술적 생산효율성은 전반적으로 수익성과 양(+)의 영향 관계를 가지나, 소규모 구역전기사업자와 같이 열 생산 비중이 높은 사업자는 수익성이 악화됨을 확인하였다. 이는 현재 열 판매 시장의 구조적 한계로 인한 현상이며, 수익성 개선을 위해서는 열 판매단가에 대한 조정이 필요함을 확인하였다.

마이크로 전력계통에서 연료전지 발전시스템의 전기/열의 최적운영 기법 연구 (Optimal Electricity and Heat Production Strategies of Fuel Cell Device in a Micro-grid Energy System)

  • 이주원;박종배;김수덕;김창섭
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1093-1099
    • /
    • 2009
  • Alternative energy sources such as renewable energy like solar power systems, wind power systems, or fuel cell power systems has been the rising issue in the electrical power system. This paper discusses an economic study analysis of fuel cells in the korean electricity market. It includes the basic concept of a fuel cell and the korean electricity market. It also describes the need of renewable energy and how the fuel cell is connected with the local grid. This paper shows the impact of production and recovering thermal energy of a grid-connected fuel cell power system. The profit maximization approach has been structured including electrical power trade with the local grid and heat trade within the micro-grid. The strategies are evaluated using a local load that uses electric and thermal power which has different patterns between summer and winter periods. The solution algorithm is not newly developed one, but is solved by an application called GAMS. Results indicate the need and usefulness of a fuel cell power system.

Characteristics of Ni/YSZ Cermet Prepared by Mechanical Alloying Method for the High Temperature Electrolysis of Steam

  • Choo, Soo-Tae;Kang, Kyoung-Hoon;Chae, Ui-Seok;Hong, Hyun-Seon;Hwang, Kab-Jin;Bae, Ki-Kwang;Shin, Seock-Jae
    • 한국세라믹학회지
    • /
    • 제43권12호
    • /
    • pp.764-767
    • /
    • 2006
  • Ni/YSZ $(Y_2O_3-stabilized\;ZrO_2)$ composite as an electrode component for High Temperature Electrolysis (HTE) was fabricated by mechanical alloying method using Ni and YSZ powders. Characterization of the synthesized composite was investigated with various analysis tools, including XRD, SEM and PSA, and a self-supporting planar unit cell prepared with the Ni/YSZ composite was prepared to study the electrochemical reactions for the production of hydrogen. The Ni/YSZ cermet is composed of crystalline Ni and YSZ, in a sub-micro scale, and has an even distribution without aggregated particles. In addition, under an electrochemical reaction, the unit cell showed an $H_2$ evolution rate from steam of 14 Nml/min and $600mA/cm^2$ of current density at the electrode.

유기농자재의 탄소배출량 산정을 위한 전과정평가(LCA) -패화석, 팽연왕겨, 보르도액을 중심으로- (LIfe Cycle Assessment(LCA) for Calculation of the Carbon Emission Amount of Organic Farming Material -With Oyster-shell, Expanded Rice Hull, Bordeaux Mixture Liquid-)

  • 윤성이;양동욱
    • 한국유기농업학회지
    • /
    • 제20권4호
    • /
    • pp.475-490
    • /
    • 2012
  • Since 1997, Korean Ministry of Knowledge Economy and Ministry of Environment have established data on some 400 basic raw and subsidiary materials and process like energy, petro-chemical, steel, cement, glass, paper, construction materials, transportation, recycling and disposal etc by initiating establishment of LCI database. Regarding agriculture, Rural Development Administration has conducted establishment of LCI database for major farm products like rice, barley, beans, cabbage and radish etc from 2009, and released that they would establish LCI database for 50 items until 2020 later on. The domestic LCI database for seeds, seedling, agrochemical, inorganic, fertilizer and organic fertilizer etc is only at initial stage of establishment, so overseas LCI databases are brought and being used. However, since the domestic and overseas natural environments differ, they fall behind in reliability. Therefore, this study has the purpose to select organic farming materials, survey the production process for various types of organic farming materials and establish LCI database for the effects of greenhouse gas emitted by each crop during the process. As for selecting methods, in this study organic farming materials were selected in the method of direct observation of material and bottom-up method a survey method with focus on the organic farming materials admitted into rice production. For the basic unit of carbon emission amount by the production of 1kg of organic farming material, the software PASS 4.1.1 developed by Korea Accreditation Board under Ministry of Knowledge Economy was used. The study had the goal to ultimately provide basic unit to calculate carbon emission amount in executing many institutions like goal management system and carbon performance display system etc in agricultural sector to be conducted later on. As a result, emission basic units per 1kg of production were calculated to be 0.04968kg-$CO_2$ for oystershells, 0.004692kg-$CO_2$ for expanded rice hull, and 1.029kg-$CO_2$ for bordeaux mixture liquid.

Analysis of Compression and Cushioning Behavior for Specific Molded Pulp Cushion

  • Jongmin Park;Gihyeong Im;Kyungseon Choi;Eunyoung Kim;Hyunmo Jung
    • 한국포장학회지
    • /
    • 제30권1호
    • /
    • pp.53-62
    • /
    • 2024
  • Molded pulp products has become more attractive than traditional materials such as expanded polystyrene foam (EPS) owing to low-priced recycled paper, environmental benefits such as biodegradability, and low production cost. In this study, various design factors regarding compression and cushioning characteristics of the molded pulp cushion with truncated pyramid-shaped structural units were analyzed using a test specimen with multiple structural units. The adopted structural factors were the geometric shape, wall thickness, and depth of the structural unit. The relative humidity was set at two levels. We derived the cushion curve model of the target molded pulp cushion using the stress-energy methodology. The coefficient of determination was approximately 0.8, which was lower than that for EPS (0.98). The cushioning performance of the molded pulp cushion was affected more by the structural factors of the structural unit than by the material characteristics. Repeated impacts, higher static stress, and drop height decreased the cushioning performance. Its compression behavior was investigated in four stages: elastic, first buckling, sub-buckling, and densification. It had greater rigidity during initial deformation stages; then, during plastic deformation, the rigidity was greatly reduced. The compression behavior was influenced by structural factors such as the geometric shape and depth of the structural unit and environmental conditions, rather than material properties. The biggest difference in the compression and cushioning characteristics of molded pulp cushion compared to EPS is that it is greatly affected by structural factors, and in addition, strength and resilience are expected to decrease due to humidity and repetitive loads, so future research is needed.

Comparative Calorimetric Evaluation of Ammoniated Straw-Based Rations Supplemented with Low Levels of Untreated and Formaldehyde Treated Groundnut Cake and Fish Meal with Respect to Growing Buffalo Calves

  • Tiwari, C.M.;Jadhao, S.B.;Chandramoni, Chandramoni;Murarilal, Murarilal;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권6호
    • /
    • pp.761-773
    • /
    • 2000
  • Eighteen growing male Murrah buffalo (Bubalus bubalis) calves were divided into three groups consisting of six animals each and fed three urea ammoniated wheat straw (UAS) -based rations supplemented with concentrate mixtures (roughage: concentrate ratio 58:42) containing deoiled ground nut cake, GNC (8%), formaldehyde treated GNC (8%) or fish meal (8%) to undertake comparative evaluation of these rations in terms of their $CH_4$ production and growth (285 d duration) potential. A digestibility trial (10 d duration) was followed by a comparative calorimetric study in respiration chamber. Dry matter (DM) intake (84.3 to $89.3g/kg\;W^{0.75}d^{-1}$) did not differ between treatments. The digestibility coefficient of DM, organic matter (OM), crude protein (CP), neutral and acid detergent fiber did not differ significantly in different diets. Urinary energy loss as a percent of gross energy (GE) was not affected by diets. Average values of $CH_4$ production were 84.3, 77.6 and 99.1 g/d and $CH_4$ energy losses as percent of gross energy were 5.7, 5.2 and 6.1 percent on .GNC, formaldehyde treated GNC and fishmeal, respectively, and did not differ significantly. When expressed per unit of digestible OM intake, $CH_4$ production (g) was lower (p<0.05) on formaldehyde treated GNC (30.6) than on untreated GNC (30.6) and fish meal (31.9). Total ME intake and heat production were similar and hence the energy balances on different diets were similar. Nutritive value of rations in terms of digestible CP and ME were similar. Average daily gain calculated on the basis of regression of fortnights on cumulative liveweight gain in calves fed on concentrate containing unprotected GNC, protected GNC and fish meal were 437.1, 483.9 and 481.6 g, respectively. This indicated that the intake of energy was sufficient to meet the requirement of calves growing at 400 g per d. However, CP intake was around 150% of the stipulated standard (Kearl, 1982). Feed conversion ratios on unprotected GNC, protected GNC and fish meal were 11.60, 11.10 and 10.4 respectively. It was concluded that because significantly (p<0.05) low $CH_4$ is produced on protected GNC (8%), it is very good and sustainable protein source in comparison to poor quality fish meal and untreated GNC to be used in concentrate mixture for supplementing UAS-based diets.

계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구 (Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments)

  • 권영현;강준구;고영재;유하녕;권준화;박호연;전태완;이영기
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

Cation exchange membrane and anion exchange membrane aided electrolysis processes for hypochlorite generation

  • Seong K. Kim;Dong-Min Shin;Ji Won Rhim
    • Membrane and Water Treatment
    • /
    • 제14권2호
    • /
    • pp.55-63
    • /
    • 2023
  • In this study, the influence of different IEMs (ion exchange membranes) to performance of the hypochlorite electrolysis unit with Cl2 recovery stream was investigated. More specifically, Nafion 117-a representative cation exchange membrane (CEM)-and aminated polypheylene oxide (APPO)-an anion exchange membrane (AEM)-were installed in the hypochlorite electrolysis unit, and the performance and the energy efficiency of the units were evaluated and compared. Regardless of whether CEM (Nafion 117) or AEM (APPO) was installed, the rate of hypochlorite generation was increased (by up to 24.3% and 22.2% for Nafion 117 and APPO, respectively) compared with the unit without an IEM. On the other hand, the power efficiency and the optimum operation condition of hypochlorite production units seem to depend on the conductivity and stability of the installed IEM. As the result, between Nafion 117 and APPO, higher performance and efficiency were achieved with Nafion 117, due to excellent conductivity and stability of the membrane.

첨단 검침 인프라에서 에너지 효율을 위한 기기 할당 방안 (The Device Allocation Method for Energy Efficiency in Advanced Metering Infrastructures)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.33-39
    • /
    • 2020
  • A smart grid is a next-generation power grid that can improve energy efficiency by applying information and communication technology to the general power grid. The smart grid makes it possible to exchange information about electricity production and consumption between electricity providers and consumers in real-time. Advanced metering infrastructure (AMI) is the core technology of the smart grid. The AMI provides two-way communication by installing a modem in an existing digital meter and typically include smart meters, data collection units, and meter data management systems. Because the AMI requires data collection units to control multiple smart meters, it is essential to ensure network availability under heavy network loads. If the load on the work done by the data collection unit is high, it is necessary to allocation new data collection units to ensure availability and improve energy efficiency. In this paper, we discuss the allocation scheme of data collection units for the energy efficiency of the AMI.