• Title/Summary/Keyword: Uniform size

Search Result 1,478, Processing Time 0.036 seconds

Physio-mechanical and X-ray CT characterization of bentonite as sealing material in geological radioactive waste disposal

  • Melvin B. Diaz;Sang Seob Kim;Gyung Won Lee;Kwang Yeom Kim;Changsoo Lee;Jin-Seop Kim;Minseop Kim
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.449-459
    • /
    • 2023
  • The design and development of underground nuclear waste repositories should cover the performance evaluation of the different components such as the construction materials because the long term stability will depend on their response to the surrounding conditions. In South Korea, Gyeonju bentonite has been proposed as a candidate to be used as buffer and backfilling material, especially in the form of blocks to speed up the construction process. In this study, various cylindrical samples were prepared with different dry density and water content, and their physical and mechanical properties were analyzed and correlated with X-ray CT observations. The main objective was to characterize the samples and establish correlations for non-destructive estimation of physical and mechanical properties through the utilization of X-ray CT images. The results showed that the Uniaxial Compression Strength and the P-wave velocity have an increasing relationship with the dry density. Also, a higher water content increased the values of the measure parameters, especially for the P-wave velocity. The X-ray CT analysis indicated a clear relation between the mean CT value and the dry density, Uniaxial Compression Strength, and P-wave velocity. The effect of the higher water content was also captured by the mean CT value. Also, the relationship between the mean CT value and the dry density was used to plot CT dry densities using CT images only. Moreover, the histograms also provided information about the samples heterogeneity through the histograms' full width at half maximum values. Finally, the particle size and heterogeneity were also analyzed using the Madogram function. This function identified small particles in uniform samples and large particles in some samples as a result of poor mixing during preparation. Also, the μmax value correlated with the heterogeneity, and higher values represented samples with larger ranges of CT values or particle densities. These image-based tools have been shown to be useful on the non-destructive characterization of bentonite samples, and the establishment of correlations to obtain physical and mechanical parameters solely from CT images.

Synthesis and Characteristic Evaluation of Downward Conversion Phosphor for Improving Solar Cell Performance (태양전지 성능향상을 위한 하향변환 형광체의 합성 및 특성평가)

  • Jae-Ho Kim;Ga-Ram Kim;Jin-To Choi;Soo-Jong Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.523-528
    • /
    • 2023
  • The applicability as a material to improve solar cell performance was reviewed by synthesizing a phosphor that emits red wavelengths by a liquid synthesis method using a metal salt aqueous solution and a polymer medium as a starting material. An aqueous solution was prepared using nitrate of metals such as Ca, Zn, Al, and Eu, and a precursor impregnated with starch, a natural polymer, was sintered to synthesize CaZnAlO:Eu phosphor powder. The surface structure and composition analysis of the synthesized CaZnAlO:Eu phosphor powder were analyzed by scanning electron microscope(SEM) and energy-dispersed X-ray spectroscopy(EDS). The crystal structure of CaZnAlO:Eu phosphor particles was analyzed by an X-ray diffraction analyzer (XRD). As a result of measuring the photoluminescence(PL) characteristics of the phosphor, it was confirmed that a red phosphor with a light emitting wavelength of 650-780nm was successfully synthesized. According to SEM and EDS analysis, the synthesized Ca14Zn6Al9.93O35:Eu3+0.07 phosphor powder has a uniform particle size, and Eu ions used as an activator are present. The synthesized CZA:Eu3+ phosphor can be used as a material that can increase the light absorption efficiency of the solar cell by converting ultraviolet or visible light down conversion into a wavelength in the near-infrared region.

Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT (관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도)

  • Yon-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1033-1039
    • /
    • 2023
  • Low-dose chest CT, which is used as a lung screening test, also includes information on coronary artery calcification within the scan range. The purpose of this study was to investigate the usefulness of determining coronary artery calcification using Low-dose chest CT. Those who underwent low-dose chest CT and coronary artery calcification score CT on the same day were eligible. Coronary artery calcium score CT results were divided into 4 groups (Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS) by referring to the Coronary artery calcium score categories and risks. After selecting 30 people each group, five radiotechnologists with more than 15 years of experience in coronary artery calcium measurement retrospectively analyzed the presence or absence of coronary artery calcification in low-dose chest CT images. The results of the five observers' uniform interpretation of the low-dose chest CT image were consistent with the coronary artery calcium score CT results in Low group: 56%, Mild group: 96.6%, Moderate group: 100%, and High group: 100%. appeared. In the Low group, all 5 observers observed calcification in 17 out of 30 cases, and in 7 cases all 5 observers decided that calcification could not be identified. Coronary artery calcification could be observed in 100% of asymptomatic adults with a calcium score of 15 or higher in low-dose chest CT scans. The minimum calcium score that can be identified is 1, and it was found that even very small calcifications can be identified when the subject's body size is small or the scan is performed at a time when heart movement is minimal.

Structural and Electrical Properties of K(Ta0.70Nb0.30)O3/K(Ta0.55Nb0.45)O3 Heterolayer Thin Films for Electrocaloric Devices (전기 열량 소자로의 응용을 위한 K(Ta0.70Nb0.30)O3/K(Ta0.55Nb0.45)O3 이종층 박막의 구조적, 전기적 특성)

  • Byeong-Jun Park;Ji-Su Yuk;Sam-Haeng Yi;Myung-Gyu Lee;Joo-Seok Park;Sung-Gap Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.297-303
    • /
    • 2024
  • In this study, KTN heterolayer thin films were fabricated by alternately stacking films of K(Ta0.70Nb0.30)O3 and K(Ta0.55Nb0.45)O3 synthesized using the sol-gel method. The sintering temperature and time were 750℃ and 1 hour, respectively. All specimens exhibited a polycrystalline pseudo-cubic crystal structure, with a lattice constant of approximately 0.398 nm. The average grain size was around 130~150 nm, indicating relatively uniform sizes regardless of the number of coatings. The average thickness of a single-coated film was approximately 70 nm. The phase transition temperature of the KTN heterolayer films was found to be approximately 8~12℃. Moreover, the 6-coated KTN heterolayer film displayed an excellent dielectric constant of about 11,000. As the number of coatings increased, and consequently the film thickness, the remanent polarization increased, while the coercive field decreased. The 6-coated KTN heterolayer film exhibited a remanent polarization and coercive field of 11.4 μC/cm2 and 69.3 kV/cm at room temperature, respectively. ΔT showed the highest value at a temperature slightly above the Curie temperature, and for the 6-coated KTN heterolayer film, the ΔT and ΔT/ΔE were approximately 1.93 K and 0.128×10-6 K·m/V around 40℃, respectively.

Fabrication of Silica Nanoparticles by Recycling EMC Waste from Semiconductor Molding Process and Its Application to CMP Slurry (반도체 몰딩 공정에서 발생하는 EMC 폐기물의 재활용을 통한 실리카 나노입자의 제조 및 반도체용 CMP 슬러리로의 응용)

  • Ha-Yeong Kim;Yeon-Ryong Chu;Gyu-Sik Park;Jisu Lim;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.1
    • /
    • pp.21-29
    • /
    • 2024
  • In this study, EMC(Epoxy molding compound) waste from the semiconductor molding process is recycled and synthesized into silica nanoparticles, which are then applied as abrasive materials contains CMP(Chemical mechanical polishing) slurry. Specifically, silanol precursor is extracted from EMC waste according to the ultra-sonication method, which provides heat and energy, using ammonia solution as an etchant. By employing as-extracted silanol via a facile sol-gel process, uniform silica nanoparticles(e-SiO2, experimentally synthesized SiO2) with a size of ca. 100nm are successfully synthesized. Through physical and chemical analysis, it was confirmed that e-SiO2 has similar properties compared to commercially available SiO2(c-SiO2, commercially SiO2). For practical CMP applications, CMP slurry is prepared using e-SiO2 as an abrasive and tested by polishing a semiconductor chip. As a result, the scratches that are roughly on the surface of the chip are successfully removed and turned into a smooth surface. Hence, the results present a recycling method of EMC waste into silica nanoparticles and the application to high-quality CMP slurry for the polishing process in semiconductor packaging.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Determination of Chimera Types and Ploidy Level of Sports from 'Campbell Early' Grape (Vitis labruscana) (포도 '캠벨얼리' 품종에서 발생한 아조변이체의 배수성 및 키메라 형태 검정)

  • Noh, Jung-Ho;Park, Kyo-Sun;Yun, Hae-Keun;Do, Gyung-Ran;Hur, Youn-Young;Kim, Seung-Hui;Lee, Han-Chan;Ryou, Myung-Sang;Park, Seo-Jun;Jung, Sung-Min
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.996-1002
    • /
    • 2010
  • Flow cytometry (FCM) was used to measure the ploidy level of three different sports from 'Campbell Early' ($Vitis$ $labruscana$) grape. Results of the study showed different ploidy levels. FCM analysis for 'Campbell Early' grape which contains 2C DNA diploid cells showed single peak around 35-40 while 'Kyoho' grape with 4C DNA tetraploid cells had a different level of 70-80. However, analysis of the sports displayed a histogram with 2 peaks containing both 2C and 4C nuclei. There was no difference in histograms of 2C DNA flesh and pericarp; on the other hand, 4C DNA flesh type of sports had a different histogram from that of the 2C DNA pericarp. Chromosome numbers of diploid ('Campbell Early'), tetraploid ('Kyoho'), and three sports were counted under the microscope. 'Campbell Early' and 'Kyoho' have 38 and 76 chromosomes, respectively. Three different sports are mixoploids with mixtures of diploid and tetraploid cells. Microscopic observations of shoot apical meristems in sports from 'Campbell Early' grape were carried out to determine the type of plant chimera. 'Campbell Early' grape (diploid) and 'Kyoho' grape (tetraploid) showed that both had 2 tunica layers covering corpus cells, while the three different sports had tunica layers showing mostly oblique division. Most cells from 'Kyoho' grape were larger than 'Campbell Early' grape. Cells from L-2 and L-3 layers of the three sports were similar to 'Kyoho' grape in size, although all cells in L-1 surface layer were uniform in size like 'Campbell Early' grape. Results of FCM analysis indicated that both normal and polyploid cells could be intermixed in sports and could become mixoploidy consisting of diploid and tetraploid. All sports used in the tests were periclinal chimera plants with two distinct L-1 and L-2 cell layers. The result of this study suggests that all three sports which originated from 'Campbell Early' grape might be 2-4-4 type chimera formation.

The Importance and Performance Analysis of Service Encounter Quality by Types of Restaurants (레스토랑 유형별 서비스 인카운터 품질의 중요도 및 수행도 분석)

  • Jo, Mi-Na
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.8
    • /
    • pp.1076-1087
    • /
    • 2006
  • The purpose of this study was to identify critical control points of service encounter by types of restaurants in order to manage moment of truth when customers encounter services. Questionnaires were collected from 812 customers (aged 15 years or older) who had used restaurants in Seoul, from October 24, 2005 to November 6, 2005. The main results of this study were as follows: Statistically significant differences were shown between importance and performance of interaction quality, physical environment quality and outcome quality. Significant differences were also shown in importance and performance of interaction and physical environment quality, and performance of outcome quality by restaurant types but no significant difference was indicated in importance of outcome quality by restaurant types. That is, the importance of outcome quality, which means the quality of food, was regarded as important by customers who use restaurants regardless of types of restaurants. The result of examining interaction quality showed that family restaurants managed waiting customers quite well and provided information on the Internet homepage. Performance of responding to customers with complaints was rated the highest in family restaurants. Regarding physical environment quality, importance and performance scores significantly differed by types of restaurants in order of fine-dining restaurants, family restaurants, and fast-food restaurants. In terms of service encounter quality, items whose importance scores were high but performance scores were low in importance-performance analysis matrix were 'quality of provided food is always uniform' and 'the space between other tables is enough' for fine-dining restaurants. In family restaurants, 'size of chairs or tables is enough', and 'the space between other tables is enough' were included in the items, while 'interior facilities are attractive', 'size of chairs and tables is enough', and 'the space between other tables is enough' were included in the items in case of fast-food restaurants. A difference was indicated depending on types of restaurants.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Development of Sample Survey Design for the Industrial Research and Development Statistics (표본조사에 의한 기업 연구개발활동 통계 작성방안)

  • Cho, Seong-Pyo;Park, Sun-Young;Han, Ki-In;Noh, Min-Sun
    • Journal of Technology Innovation
    • /
    • v.17 no.2
    • /
    • pp.1-23
    • /
    • 2009
  • The Survey on the Industrial Research and Development(R&D) is the primary source of information on R&D performed by Korea industrial sector. The results of the survey are used to assess trends in R&D expenditures. Government agencies, corporations, and research organizations use the data to investigate productivity determinants, formulate tax policy, and compare individual company performance with industry averages. Recently, Korea Industrial Technology Association(KOITA) has collected the data by complete enumeration. Koita has, currently, considered sample survey because the number of R&D institutions in industry has been dramatically increased. This study develops survey design for the industrial research and development(R&D) statistics by introducing a sample survey. Companies are divided into 8 groups according to the amount of R&D expenditures and firm size or type. We collect the sample from 24 or 8 sampling strata and compare the results with those of complete enumeration survey. The estimates from 24 sampling strata are not significantly different to the results of complete enumeration survey. We propose the survey design as follows: Companies are divided into 11 groups including the companies of which R&D expenditures are unknown. All large companies are included in the survey and medium and small companies are sampled from 70% and 3%. Simple random sampling (SRS) is applied to the small company partition since they show uniform distribution in R&D expenditures. The independent probability proportionate to size (PPS) sampling procedure may be applied to those companies identified as 'not R&D performers'. When respondents do not provide the requested information, estimates for the missing data are made using imputation algorithms. In the future study, new key variables should be developed in survey questionnaires.

  • PDF