• 제목/요약/키워드: Uniform Droplets

Search Result 65, Processing Time 0.186 seconds

The effects of non-uniform droplets distribution on the characteristics of group combustion for liquid fuel droplets cloud (비균일 액적분포가 액적군의 집단연소 특성에 미치는 영향)

  • 김호영;전철균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.479-487
    • /
    • 1987
  • In order to predict the effects of droplets distributions such as number density and droplets size on group combustion characteristics and flame structure for liquid fuel sprays, modifications of group combustions model were made by changing the droplets distributions from uniform to non-uniform. Various droplets distribution models were adopted in this analysis to examine the effect of number density distribution on combustion characteristics and the difference between uniform and non-uniform droplets size distributions for a spherical droplets cloud. As results of present study, hollow droplets could with outer concentrating distribution has shorter total combustion time compare with the case of solid droplets cloud with inner concentrating distribution. Uniform droplets size distribution model predicts the shorter total combustion time compare with non-uniform droplets size distribution model, and the uniform droplets size distribution model may be used to predict the total combustion time for the droplets cloud containing larger initial size of droplets.

Size Distribution of Droplets Sprayed by an Orchard Sprayer (과수방제기 살포입자의 직경 분포특성)

  • 구영모;신범수;김상헌
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.431-440
    • /
    • 2001
  • Generated agri-chemical droplets by orchard sprayers are evaporated regenerated and transported along wind streams. The droplets are deposited to targets after changing their sizes, affecting the retention of droplets. An orchard sprayer, designed for spraying grapevines was studied on the spatial distribution of droplet size. The experimental variables were spray direction (0, 22.5, 45, 67.5 and 90˚), distance(2.5, 3.0 and 3.5 m) and fan speed (2,075 and 3,031 rpm). Droplet sizes were converted and analyzed from spray stains, sampled using water sensitive papers. The number median diameter (NMD) increased with an increase of the distance due to disappeared fine droplets (<50 ㎛): however, the volume median diameter (VMD) decreased due to shrunken large droplets (>100 ㎛). Fast fan speed delivered large droplets to 3.5 m, but the spatial distributions of NMD and VMD were not uniform. Slower fan speed decreased the possibility of evaporation and drift; therefore, plenty of droplets were maintained up to 3.0 m. The upward blasting distance was limited within 3 m, but the limit to the ground level was extended to 3.5 m. Concentrated wind and droplets to the ground level should be redistributed to upper canopy direction, leading more uniform deposits. High speed wind and system pressure should be avoided because of generating fine droplets, which would be disappeared and drifted away.

  • PDF

A study on Characteristics of the Liquid Atomization by Ultrasonic (초음파에 의한 액체 미립화 특성에 관한 연구)

  • 주은선;나우정;최우창
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.31-39
    • /
    • 1999
  • A good atomization in uniform size brings the elevation of thermal efficiency in spray combustion, the beautiful painting on surfaces, and the economical sprinkling of chemicals. Ultrasonic atomization has been expected as a good uniform atomization mechanism due to its uniform size distribution. Influx, load, and physical properties of liquids are the effecting factors to atomize liquids. In this study, distilled water and city water are selected as reference liquids and gasoline, kerosene, and petroleum as fuel liquids. Characteristics and affinity to get the maximum effect for the ultrasonic atomization are observed by using the two ultrasonic transducers with 28kHz and 2MHz. Results show that the size distributions of liquid spray dorplet by the direct vibration method prevail over those by the aerosol method in uniform droplet size and as a whole, sizes of spray liquid droplets are increased slightly according to increasing influx in the direct vibration method and quantities of spray droplets in the aerosol method decreasing according to increasing liquid load h.

  • PDF

Group Ignition of Liquid Fuel Droplets Cloud (액체연료 액적군의 집단 점화)

  • 박용열;김호영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2376-2384
    • /
    • 1992
  • A theoretical analysis is carried out to predict the characteristics of transient ignition phenomena for the spherical fuel droplets cloud with non-uniform droplet size and number density distribution. Numerical calculations are performed for various cases depending on the combinations of the major parameters such as ambient temperature and initial distributions of droplet size and number density. The results of present study show that the ignition delay decreases for higher ambient temperature and smaller droplet size. Droplets cloud of hollow type with outer concentrated distribution ignites most rapidly.

Coverage Distribution of Blasted Droplets by an Orchard Sprayer (과수방제기 살포입자의 도포율 분포특성)

  • 구영모;김상헌;신범수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.355-362
    • /
    • 2001
  • Uniform application of agri-chemicals will improve orchard pest management. An air-blast(orchard) sprayer designed for vineyards has been used: however, few research on the uniformity and coverage of the sprays has been reported. Distributions of spray coverage were measured with artificial targets and analyzed to enhance the efficiency of spray application. A structure was built to place water sensitive papers, sampling spray droplets blasted from the orchard sprayer. The sampling cards were collected from five directions at three distances (2.5, 3.0 and 3.5m) for two fan speeds (2,075 and 3,031 rpm), and analyzed using an image analysis system. The distribution of the coverage percent area did not follow the wind velocity pattern. The coverage by the low fan speed was more uniform and higher than that by the higher fan speed. The coverage percent area decreased with an increase of distance. The distribution of droplet density was similar to that of coverage. However, the coverage contribution by smaller droplets became more significant as the distance increased. The upward blasting distance was limited within 3m, but the limit to the ground level was expanded the distance more than 3.5m because of the concentrated droplets.

  • PDF

Generation of uniform Fine Droplets Under Spindle Mode in Electrohydrodynamic Atomization (스핀들 모드하의 전기수력학적 미립화를 통한 균일 미세액적 생성)

  • Lee, Sang-Yong;Kim, Myeong-Chan;Kim, Sang-Su;Kim, Yu-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.7
    • /
    • pp.923-932
    • /
    • 2001
  • A series of experiments were conducted to generate fine liquid(water) drops through the electrohydrodynamic atomization process. The atomization mode depended on flow rate and DC voltage input. For water, having electric conductivity larger than 10(sup)-7S/m, the spindle mode turned out to be the only mode to generate uniform-size drops within the range of 30-450 microns that have wide applications. Within this mode, both the uniformity and the fineness of drops were improved at an optimum voltage input for a given flow rate. This optimum voltage increased with increasing of the liquid flow rate. Another important parameter considered was the nozzle material with different electric conductivity and liquid wettability. A stainless-steel nozzle (the material with high electric conductivity and high liquid wettability) and a silica nozzle (the electrically non-conducting material with low liquid wettability) were tested and compared; and more uniform drops could be obtained with the silica nozzle.

SPRAY STRUCTURE OF HIGH PRESSURE GASOLINE INJECTOR IN A GASOLINE DIRECT INJECTION ENGINE

  • Lee, Chang Sik;Chon, Mun Soo;Park, Young Cheol
    • International Journal of Automotive Technology
    • /
    • v.2 no.4
    • /
    • pp.165-170
    • /
    • 2001
  • This study is focussed on the investigation of spray characteristics from the high pressure gasoline injector for the application of gasoline direct injection engine. For the analysis of spray structure of high pressure gasoline injector; the laser scattering method with a Nd-Yag laser and the Phase Doppler particle analyzer system were applied to observe the spray development and the measurement of the droplet size and velocity of the spray, respectively. Also spatial velocity distribution of the spray droplet was measured by use of the particle image velocity system. Experimental results show that high pressure gasoline injector shapes the hollow-cone spray, and produce the upward ring shaped vortex on the spray surface region. This upward ring shaped vortex promotes the secondary atomization of fuel droplets and contributes to a uniform distribution of fuel droplets. Most of fuel droplets are distributed under 31$\mu m$ of the mean droplet size (SMD) and the frequency distribution of the droplet size under 25$\mu m$ is over 95% at 7 MPa of injection pressure. According to the experimental results of PIV system, the flow patterns of the droplets velocity distribution in spray region are in good agreement with the spray macroscopic behaviors obtained from the visualization investigation.

  • PDF

Atomization of Liquid Via a Combined System of Air Pressure and Electric Field (공기 압력과 전기장이 접목된 액적 분무에 관한 연구)

  • Hwang, Sangyeon;Seong, Baekhoon;Byun, Doyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.9-12
    • /
    • 2014
  • Conventional electrospray and air spray methods have the vulnerabilities of limited flow rate (throughput) and droplet size, respectively. Since high throughput with uniform size of droplet is required for various applications, an improved technique should be adopted. Here, we report a combined system of an air pressure and an electric field and evaluate the atomization performance of it. The air flow allowed applying high flow rate range and the electric field reinforced the atomization process to generate fine droplets. A correlation between two forces was investigated by comparing the droplet produced by each method. The atomized droplets were measured and visualized by image processing and a particle image velocimetry (PIV). The quantitative results were achieved from the parametric space and the effect of both forces was analyzed. The motion of charged droplets followed the outer electric field rather than the complex vortex in the shear layer so that the droplets accelerated directly toward the grounded collector.

Spray Deposit Distribution of a Small Orchard Sprayer (소형 과수방제기 살포입자의 부착량 분포)

  • Koo, Young-Mo
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.145-152
    • /
    • 2007
  • Uniformity of spray deposit is one of the important factors in spray performance affecting efficacy of pest management. Distributions of spray deposit on artificial targets were measured and analyzed to enhance the efficiency of spray application. The research was studied to understand the deposition characteristics of spray droplets and to determine the optimum conditions of chemical application. The deposit and its pattern by the lower fan speed was more uniform and higher than that by the higher fan speed. The upward blasting distance was limited within 3 m, but the limit to the ground level was expanded the distance more than 3.5 m because of the accumulated droplets. When the fan speed was higher at the distance of 2.5 m, deposit reached to maximum. When the distance increased, deposit was getting lower. At the both fan speeds, the deposit was concentrated below $30^{\circ}$ because of the gravitation and the resistance of wind. This research can be useful in designing an orchard sprayer and its operation for various tree canopies. To achieve a uniform distribution of deposit using the air-blast type orchard sprayer, the application rate from the middle boom should be increased as the air velocity to the upward increased. The spray rate to the side boom should be limited in a minimal level.

Effects of the Electrohydrodynamic Forces on Characteristics of Spray (전기수력학적 힘이 분무특성에 미치는 영향)

  • Lee, J.H.;Kwon, S.D.;Kim, S.H.;Moon, S.Y.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.6 no.1
    • /
    • pp.44-51
    • /
    • 2001
  • The distributions of the SMD and behavior of 2% $NH_4H_2PO_4$ spray discharged from a fan-spray twin fluid type nozzle are measured and observed. The spray characteristics, according to the variation in the applied voltages, are demonstrated using the PMAS (particle Motion Analysis System) and the CCD camera, respectively. The preliminary experiments are executed to select an optimum condition for solidifying a galvanized coating layer in the uncharged condition before carrying out the main experiments. The liquid and air pressure of $0.07kgf/cm^2\;and\;0.15kgf/cm^2$ can be considered the optimum conditions to use in the main experiment. As the applied voltage increases, the frequent range of relatively large droplets diminishes. Thus, the distributions of drop diameter in the charged spray are more uniform than these in the uncharged condition. This is explained by recognizing that repulsive forces among droplets with the charges of the same sign cause them to be uniform.

  • PDF