• Title/Summary/Keyword: Underground workers

Search Result 74, Processing Time 0.024 seconds

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

Review on Design of Underground Mine Openings in Korea and Overseas (국내외 지하광산 갱도설계 현황에 대한 고찰)

  • Yoon, Dong-Ho;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.29 no.1
    • /
    • pp.30-37
    • /
    • 2019
  • Some leading countries in mining have a very quantitative guideline for underground mine opening design which is useful to minimize mine hazards such as rockfall and collapse. Those hazards sometimes can cause a huge damage on human life and property in the mines. Construction guidelines of underground mines in Korea consist of qualitative and general expressions although the workers' safety rules and guides are well provided. Recently, mining operations in Korea are going underground due to the environmental regulations and resource depletion at shallow depth, and therefore there is a growing demand on a specialized and systematic guideline for mine opening design securing the underground stability. In this paper, current status of mining industry, research trends, and mining guidelines in Korea and overseas have been reviewed to give an insight into developing a new Korean guideline for underground mine design.

A Method to Protect Mine Workers in Hot and Humid Environments

  • Sunkpal, Maurice;Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.149-158
    • /
    • 2018
  • Background: Work comfort studies have been extensively conducted, especially in the underground and meteorological fields resulting in an avalanche of recommendations for their evaluation. Nevertheless, no known or universally accepted model for comprehensively assessing the thermal work condition of the underground mine environment is currently available. Current literature presents several methods and techniques, but none of these can expansively assess the underground mine environment since most methods consider only one or a few defined factors and neglect others. Some are specifically formulated for the built and meteorological climates, thus making them unsuitable to accurately assess the climatic conditions in underground development and production workings. Methods: This paper presents a series of sensitivity analyses to assess the impact of environmental parameters and metabolic rate on the thermal comfort for underground mining applications. An approach was developed in the form of a "comfort model" which applied comfort parameters to extensively assess the climatic conditions in the deep, hot, and humid underground mines. Results: Simulation analysis predicted comfort limits in the form of required sweat rate and maximum skin wettedness. Tolerable worker exposure times to minimize thermal strain due to dehydration are predicted. Conclusion: The analysis determined the optimal air velocity for thermal comfort to be 1.5 m/s. The results also identified humidity to contribute more to deviations from thermal comfort than other comfort parameters. It is expected that this new approach will significantly help in managing heat stress issues in underground mines and thus improve productivity, safety, and health.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Real-time Underground Facility Map Production Using Drones (드론을 이용한 실시간 지하시설물도 작성)

  • NO, Hong-Suk;BAEK, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.39-54
    • /
    • 2017
  • Between 1998 and 2010, the computerization of underground facilities was completed in 84 cities. Since 2011, new pipelines have been laid or existing pipelines have been maintained, renovated, and renewed. To measure the exact location and depth of the exposure pipe, a map of underground facilities was created before filling the ground. This method is based on the time when the underground facilities of the National Geographic Information Institute Regulation No. 134 of the National Geographic Information Office revised in 2010 were drafted. The process of the drone taking the video is based on a theoretical basis of ground control points. The method works by removing all ground control points located outside of the error range and re-processing it for calculating the best result. Furthermore, using a drone-based spontaneous measuring method allows workers to obtain a high accuracy underground facilities map in error bound. The proposed method could be used as a new way to standardize the processing.

Computer Simulation for Working Condition of Undergroundwork Using TOP DOWN Technique (TOP DOWN 지하공사의 작업환경체크 컴퓨터시물레이션에 관한 기초적 연구)

  • 고성석;손기상;심경수
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.96-105
    • /
    • 1995
  • The better industry develops, the more spaces need but in the limited area. Most building become larger and more complicated if the more spaces need in the constant area. And this leads to do underground work in long period generally six(6) months for 6 basement stories due to the selection of TOP DOWN technique. Working environment in this underground area can be problems and should not be overlooked, because air quality in underground spaces become quickly worse. Recently, department name to control construction safety has been changed to ENVIRONMENT & SAFETY TEAM from SAFETY TEAM. This means that it is very important to control against environmental condition at site so much. Overall construction work as well as underground work should conform to the requirement of working environment, particularly against inhabitants around the construction area. Strut protection, one of earth protection method, in case to 40m long strut may become weaker due to thermal stress or its longitudinally compressive strain and the another one, earth anchor protection may not be applied to the site In case of encroaching on vertical underground borderline because of regulation to prohibit it. It is necessary that TOP DOWN technique should be introduced in order to solve the external and internal problem of the site such as difficulty level of the work, potential danger with excavating depth, and shortening workperiod. It is needed that improving way of working condition should be shown and simplified computer simulation program should be also provided for checking pollution level & ventilation, excluding of lighting problem here. Results measured with conformance to the Regulation for Working Environment Measurement, enforced by Ministry of Labor have been applied to the computer program developed here. Sample air taken at unit workplace which was considered as exposing condition of pollutant at breathing point and within a range of behavior of the workers, Identified exposing group in underground work, using Moded Flow Life Finally, three types of ventilation system, type I with blower & ventilator, type II natural supply with mechanical ventilation system, and type I mechanical ventilation with Drivent Fan Unit System are selected for this study.

  • PDF

Automated Systems and Trust: Mineworkers' Trust in Proximity Detection Systems for Mobile Machines

  • Swanson, LaTasha R.;Bellanca, Jennica L.;Helton, Justin
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.461-469
    • /
    • 2019
  • Background: Collisions involving workers and mobile machines continue to be a major concern in underground coal mines. Over the last 30 years, these collisions have resulted in numerous injuries and fatalities. Recently, the Mine Safety and Health Administration (MSHA) proposed a rule that would require mines to equip mobile machines with proximity detection systems (PDSs) (systems designed for automated collision avoidance). Even though this regulation has not been enacted, some mines have installed PDSs on their scoops and hauling machines. However, early implementation of PDSs has introduced a variety of safety concerns. Past findings show that workers' trust can affect technology integration and influence unsafe use of automated technologies. Methods: Using a mixed-methods approach, the present study explores the effect that factors such as mine of employment, age, experience, and system type have on workers' trust in PDSs for mobile machines. The study also explores how workers are trained on PDSs and how this training influences trust. Results: The study resulted in three major findings. First, the mine of employment had a significant influence on workers' trust in mobile PDSs. Second, hands-on and classroom training was the most common types of training. Finally, over 70% of workers are trained on the system by the mine compared with 36% trained by the system manufacturer. Conclusion: The influence of workers' mine of employment on trust in PDSs may indicate that practitioners and researchers may need to give the organizational and physical characteristics of each mine careful consideration to ensure safe integration of automated systems.

Analysis of Macpa Stress Index and Work Ability Index on Subway Construction Workers (도시철도 건설종사자의 맥파 스트레스 지수와 작업능력 지수 분석)

  • Chae, Joung Sik;Lee, Jong bin;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.58-62
    • /
    • 2022
  • Metro subway construction is a field that requires a great deal of professional manpower. The aging of professionals has a negative impact on both productivity and health, owing to poor working environments, heavy lifting, underground work, and other factors. To address this issue, the government is progressively revising and enforcing health management law and regulation in the construction industry. Thus, the job stress and work ability of many professional subway construction workers, who are rapidly aging, are being analyzed to ensure their safety and improve their health. In this study, the Macpa stress index of Busan Metro Subway construction workers from Sasang to Hadan line was measured by using a Macpa measurement machine, and a work ability survey was conducted by using the questionnaire that was developed by the FIOH. The independent variables were age, years of service, job position, employment type, and occupation. While, the dependent variables were the Macpa stress index and work ability. The Kruskal-Wallis test was used because it was difficult to assume that the statistics of this study represented a normal distribution. The results showed that age, job position, and employment type affected Macpa stress index and revealed that as the age of the workers increased, their stress levels increased as well. Additionally, job position and employment type affected the work ability of the metro subway construction workers. In terms of job position, the technical engineers were under a lot of stress, and whereas the managers had the best work ability. The technical engineers were more stressed than the other workers because of a poor working environment. In terms of employment type, daily workers were under more stress and lower work ability than others.

Suspended Particulate Concentration at the Drilling Site of Underground Coal Mines in Taebaek Area (태백지역 석탄광업 굴진부서의 부유분진 농도)

  • 윤영노;김영식;이영신
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.32-38
    • /
    • 1991
  • Airborne suspended particulate concentration in drilling sites of underground coal mines in Taebaek area was evaluated. And respirable coal dust exposure level was evaluated. Airborne suspended particulate mass include total suspended particle(TSP) and thoracic particle(TPM). TSP (by open-face filter holder) and TPM(by elutriator) concentration were determined by low volume air samplers. Personal air samplers were attached to the coal workers including drillers, coal cutters, and their assistants. Normality and log-normality of TSP, TPM, and respirable dust(RPM) concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of TSP, TPM, and RPM concentration were tested by paired t-test. Relation between TSP, TPM, and RPM with pairs were tested by regression test and Pearson's correlation.

  • PDF

A Study on the Countermeasure to the Stray Current in Underground (지중 표유전류 저감 대책에 관한 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Choi, S.B.;Jeong, S.H.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1159-1162
    • /
    • 1998
  • The induced voltage of underground pipelines caused by the stray current not only do harm to workers and instruments. but also cause big accident such as gas explosion. The AC stray current is mainly produced by the grounding system of the 22.9kV distribution power system and the DC stray current is mainly produced by the subway system. The mechanism of AC and DC induction, stray current failure examples of domestic and foreign countries and the countermeasure of the AC and DC induction are described.

  • PDF