• 제목/요약/키워드: Underground transmission cables

검색결과 109건 처리시간 0.026초

초전도케이블 시장진입 가격 산정 방법론 고찰 (Methodology for Estimating the HTS Cable Market Price)

  • 김종율;이승렬;윤재영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권10호
    • /
    • pp.536-541
    • /
    • 2004
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density, stronger magnetic fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In these days, companies world-wide have conducted researches on HTS cable. A development project for a 22.9kV class HTS cable is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS cable to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional cable is calculated and based on this, the expected price of HTS cable is evaluated, which HTS cable is competitive against conventional cable.

관로포설 지중케이블에서 개량되메움재 적용시의 송전용량 증대효과 검토 (A Study on Power Transmission Capacity of Improved Backfill Materials at Underground Cables Installed in Duct Type)

  • 장태인;강지원;이동일;김재승;탁의균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.345-347
    • /
    • 2002
  • 이 논문은 현재 지중송전 케이블에서 관로포설용 되메움재로서 널리 사용되고 있는 모래를 대신할 수 있는 개량 되메움재 연구하고, 이에 대한 송전용량 증대효과를 살펴본 것이다. 먼저, 기존 되메움재인 모래 및 개량 되메움새에 대한 토양 열특성을 비교 검토하고, 다음으로 개량 되메움재를 실선로에 적용할 때의 송전용량 증대 효과를 시뮬레이션을 통해 확인하였다.

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

송전 XLPE 케이블 절연층을 이용한 전기트리 형성과 부분방전 양상의 상관관계 (A study on the correlation between the PD pattern and the formation of electrical trees by use of XLPE insulation for the underground power transmission cable)

  • 이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2051-2053
    • /
    • 1999
  • In this work, PD patterns and electrical trees are observed by use of the XLPE cable insulation. and the tree initiation voltage related to the contamination are also measured in order to calculate the electric stress necessary for the design of cable insulation. Throughout these works, correlation between the PD pattern and the shape of electrical tree has been observed that there may exist three distinct pattern of PD dependence on the stage of tree propagation, Such correlation could bring a basic information in connection with the partial discharge of cable system. It was also found that the electrical stress necessary for the initiation of electrical tree was measured to the 290kV/mm for the 154kV XLPE cables manufactured in KOREA.

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

Life-cycle 비용 산정을 통한 초전도케이블 경제성 검토 (A Economic feasibility of HTS cable by estimating the Life-Cycle cost)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.424-426
    • /
    • 2004
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density, stronger fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In these days, companies world-wide have conducted researches on HTS cable. A development project for a 22.9kV class HTS cable is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS cable to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional cable is calculated and based on this, the expected price of HTS cable is evaluated, which HTS cable is competitive against conventional cable.

  • PDF

전력회사 계통에 22kV급 초전도 케이블 도입을 위한 적용 개소 고찰 (A Study on the Application of 22kV class Superconducting Cable in Utility Network)

  • 김종율;윤재영;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.20-29
    • /
    • 2003
  • As power systems grow more complex and power demands increase, the need of underground transmission system is increasing gradually. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable can carry very high current densities with strongly reduced conductor loss and allow high power transmission at reduced voltage. Therefore HTS cable can transfer more power to be moved in existing ducts, which means very large economical and environmental benefits. A development project for a 22kV class HTS cable is ongoing at a research centers, and the cable manufacturer in Korea. In this paper, we carried out investigation for application of 22kV class HTS cable in Korean utility networks. The results show that the HTS cable is applicable to replace IPB in pumping-up power plant, withdrawal line in distributed generation, withdrawal line in complex power plant, and conventional under ground cable. Finally, as the cost of HTS wire and refrigeration drops, the technical and economical potential of HTS cable is evaluated positively.

열특성 효과를 고려한 지중송전관로용 되메움재 개발 (Development of Backfill Materials for Underground Power Cables Considering Thermal Effect)

  • 이대수;김대홍;홍성연
    • 한국지반공학회논문집
    • /
    • 제21권6호
    • /
    • pp.41-52
    • /
    • 2005
  • 지중송전케이블의 송전용량은 케이블 또는 주변지반의 최대허용온도에 좌우되기 때문에 케이블 주위 되메움재는 운영기간동안 낮은 열저항성을 유지하여야 한다 케이블 주위에 발생된 열은 되메움재를 통해 즉시 주위에 발산시컥 제거하여야 하며, 그렇지 않으면 통상온도$(50\sim60^{/circ}C)$에서도 열폭주에 의한 절연파괴에 이를 수 있다. 본 논문에서는 열저항율이 낮은 지중송전관로의 되메움재를 개발하기 위해 다양한 첨가제를 사용하여 시험을 수행하였다. 연구결과, 영광 동림천 모래의 경우 상대적으로 균등한 입도분포를 나타내는 모래로써 함수비 $10\%$에서 $50^{\circ}C-cm/watt$, 건조시에는 $260^{\circ}C-cnuwatt$를 나타내는 등 대단히 높은 열저항치를 보여주었다. 또한 진산 화강암 석분 및 모래-자갈(D-2), 석분쇄석 혼합재(E-1)의 경우 양호한 입도분포를 나타냈으며, 열저항은 함수비 $10\%$의 경우, $35^{\circ}C-cm/watt$, 건조할 경우 $100^{\circ}C-cm/watt$를 나타냈다. 이들 연구결과를 토대로 열저항이 낮은3가지 형태의 되메움재를 제시하였다. 또한 제시된 되메움재를 대상으로 현장실증시험을 통해 적용성을 평가하였다.

지중송전관로 되메움재의 열저항 특성 (Thermal Resistivity of Backfill Materials for Underground Power Cables)

  • 김대홍;이대수
    • 한국지반공학회논문집
    • /
    • 제18권5호
    • /
    • pp.209-220
    • /
    • 2002
  • 지중송전케이블의 송전용량은 케이블 또는 주변지반의 최대허용온도에 좌우되기 때문에 케이블 주위 되메움재는 운영기간동안 낮은 열저항성을 유지하여야 한다. 케이블 주위에 발생된 열은 되메움재를 통해 즉시 주위에 발산시켜 제거하여야 하며, 그렇지 않으면 통상온도 (50~6$0^{\circ}C$)에서도 열폭주에 의한 절연파괴에 이를 수 있다. 본 논문에서는 되메움재의 열저항을 낮추기 위한 여러 가지 방법에 대해 논하였으며, 다양한 첨가제를 사용하여 시험을 수행함으로써 열저항 효과를 측정하였다. 연구결과, 영광 동림천 모래의 경우 상대적으로 균등한 입도분포를 나타내는 모래로써대단히 높은 열저항치(5$0^{\circ}C$'-cm/watt at 10% 함수비, 260-cm/watt 건조 시)를 나타냈다. 또한 진산 화강암 석분 및모래싸갈(A-2), 석분쇄석 혼합재(E-1)의 경우 양호한 입도와 낮은 열저항(35$^{\circ}C$-cm/wau 10% 함수비, 10$0^{\circ}C$-cm/watt 건조시)을 보여주었으며, 이들 연구결과를 토대로 열저항이 낮은 3가지 형태의 되메움재를 제시하였다.