• Title/Summary/Keyword: Underground temperature

Search Result 612, Processing Time 0.021 seconds

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Effect on Thermal Characteristic arid Air Pattern of System by Opening Configuration - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 -지하피트 공간 내의 개구부 형상이 시스템의 열적 특성 및 기류성상에 미치는 영향-)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper presents the effect of opening configuration on the thermal behavior and air pattern of earth tube system. The earth tube system is a fresh air load reduction system by using underground double floor space for air-conditioning. In order to analyze the effect of opening configuration on thermal performance of this system and air pattern in underground double floor space quantitatively, we used a model dealing with tree-dimensional profile of wind velocity and temperature in underground double floor space. In conclusion, it is confirmed that heat exchange of a fresh air is mainly performed with upper and lower wall in underground double floor space, and that heat exchange area increased by installing the opening near the wall.

Estimation of spatial autocorrelation variations of uncertain geotechnical properties for the frozen ground

  • Wang, Di;Wang, Tao;Xu, Daqing;Zhou, Guoqing
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.339-348
    • /
    • 2020
  • The uncertain geotechnical properties of frozen soil are important evidence for the design, operation and maintenance of the frozen ground. The complex geological, environmental and physical effects can lead to the spatial variations of the frozen soil, and the uncertain mechanical properties are the key factors for the uncertain analysis of frozen soil engineering. In this study, the elastic modulus, strength and Poisson ratio of warm frozen soil were measured, and the statistical characteristics under different temperature conditions are obtained. The autocorrelation distance (ACD) and autocorrelation function (ACF) of uncertain mechanical properties are estimated by random field (RF) method. The results show that the mean elastic modulus and mean strength decrease with the increase of temperature while the mean Poisson ratio increases with the increase of temperature. The average values of the ACD for the elastic modulus, strength and Poisson ratio are 0.64m, 0.53m and 0.48m, respectively. The standard deviation of the ACD for the elastic modulus, strength and Poisson ratio are 0.03m, 0.07m and 0.03m, respectively. The ACFs of elastic modulus, strength and Poisson ratio decrease with the increase of ratio of local average distance and scale of fluctuation. The ACF of uncertain mechanical properties is different when the temperature is different. This study can improve our understanding of the spatial autocorrelation variations of uncertain geotechnical properties and provide a basis and reference for the uncertain settlement analysis of frozen soil foundation.

Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire (지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부)

  • Kim, Seo-Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.461-468
    • /
    • 2022
  • This study is focused on the ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire. When temperature changes of same point were measured depending on sprinkler's working condition, in Scenario 1, inner temperature at border of spray applied material(SP-2) of ceiling part near the fire and ceiling insulation(blowing polystyrene) was 658.27℃ and its which inner maximum temperature is higher than 427℃ which is the ignition point of ceiling insulation(blowing polistyrene), so it was observed that flame is ignited on the ceiling insulation and spread fire. In scenario 2, Inner fire temperature at border of spray applied material(SP-2) and ceiling insulation(blowing polystyrene) near the fire was 53.10℃ and it was lower than ignition point so it was observed that flame was not ignated on the ceiling insulation. As a result, it was foreseen that possibility of ignition on the ceiling insulation depending on working condition of sprinkler.

A Study on the Performance Improvement of a Heat Pump System with a Dehumidification Function (제습기능을 구비한 열펌프의 성능개선에 관한 연구)

  • Ko, Gwang-Soo;Kim, Taehyung;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.529-534
    • /
    • 2014
  • This research developed a hybrid heat pump system with the functions of dehumidification and heating, which uses simulated air that is like underground air, from an environmental chamber as a heat source. The system consisted of three evaporators and three condensers that were installed in series in the air passage, between the underground and load space. As results, the total amount of dehumidification was 2.726 kg/h, and the heating $COP_h$ was 1.84 at air intake temperature $17^{\circ}C$ and relative humidity 70%, which is a similar condition to underground air. We found that the total amount of dehumidification also increased with the air temperature and humidity. The system $COP_s$ was reached at 2.5, if we include the latent heat of dehumidification in the conventional heat pump system's COP.

Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling II : Load Carrying Capacity (박리를 고려한 지하박스구조물의 화재하중해석 II : 내하력)

  • Lee, Gye-Hee;Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.485-492
    • /
    • 2007
  • In this study, based on the temperature distribution and the spalling histories those obtained in the companion paper, the thermal stress and moments of underground box structure were estimated. Additionally, the ultimate sectional moment considering with the thermal nonlinearities of material were estimated and the load carrying capacity of underground box structure was also obtained. As results, the load carrying capacity of negative moment part was dominated by thermal moment that come from thermal gradient of the section. However, the load carrying capacity of the positive moment part was rules by the yield stress of rebar that exposed to the high temperature induced spalling phenomena.

에코콘 관입시스템을 이용한 지반의 현장원위치 수리전도도 측정

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.262-265
    • /
    • 2004
  • The purpose of this study is to investigate environmental characteristics and in-situ hydraulic conductivity by eco cone penetration system. The underground environments and permeability of site was investigated and analyzed by this eco cone system. The electrical resistivity, pH, ORP, temperature and hydraulic conductivity were measured by eco cone penetration system. This eco cone penetration system provides a continuous environment and permeability profiles in underground, and provides reliable results for investigation of normal and contaminated ground.

  • PDF

Surveillance System For Underground Power Transmission Lines (초고압 지중선로 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.618-620
    • /
    • 1993
  • This system using optical fiber provides various information about underground tunnel and power transmission lines-atmospheric temperature, humidity, oil pressure, flammable gas, cable behavior, and so on. To transmit various data and to keep reliability, optical MUXs are adopted. User can easily operate monitoring software by using GUI.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

A study on the effects of skylight in commercial underground space - with focus on the employees of underground streets in Japan (지하상업공간에서 천창의 효과에 대한 연구 - 일본 지하가 근무자를 중심으로)

  • Lee, Gahng-Ju
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2019
  • This study examined the empirical meaning of skylight in underground space, and for this purpose, 29 questions were drawn, consisting of technical performance, functional performance, and behavioral performance. In addition, under the assumption that the meaning of the skylight will be clearly revealed through the comparison between the underground streets with and without the skylight, three underground streets with the skylight and three underground streets without the skylight of Japan were selected as the subjects of the study. Based on the results of the survey, descriptive statistical analysis and frequency analysis were conducted, and an independent sample T-test was conducted for each analysis, and correlation analysis was conducted to derive improvement priority. As a result of the analysis, it was found that skylight had a certain effect on the sense of time and imageability inside the underground commercial space. In addition, it was analyzed that skylight exerted important function in the qualitative aspect of underground commercial space. Lastly, the improvement rankings for three underground streets without skylight were derived in the order of sign/guide map, space diversity, maintenance, rest space, and floor design.The improvement rankings for three underground streets with skylight were drawn in order of resting space, diversity of space, temperature and humidity, air, and maintenance.