• Title/Summary/Keyword: Underground station

Search Result 315, Processing Time 0.027 seconds

An Experimental Study on the Damage of Waterproofing Membrane due to Oil ingredient of Underground Structures (유류성분이 지하구조물의 방수층 손상에 미치는 영향에 관한 실험적 연구)

  • Song Je-Young;Kang Hyo-Jin;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.177-180
    • /
    • 2006
  • The accidents of oil leakage is increasing in the Underground Concrete structures for Oil Storege. In the result, the waterproofing in the underground structures is melt down and cannot fulfil its Performance. This study shows an experimental study in the effects of the oil leakage to on the performance of Waterproofing Materials. In order to investigate the actual condition and the problems, a comparative analyses were conducted considering the various types of leakage. Utilizing the obtained results at the basic data for test methods and the standard of quality, we intended to propose a strategy to develop an innovated waterproofing Materials and improve the clean environment of underground structures.

  • PDF

Snow Tunnelling Project at the South Pole (남극 극지점 기지에서의 얼음 터널 프로젝트)

  • 지왕률
    • Tunnel and Underground Space
    • /
    • v.13 no.1
    • /
    • pp.1-5
    • /
    • 2003
  • The United States Antarctic program (USAP) through its principal Support Contractor Raytheon polar Services Co. (RPSC), has recently finished a 3 years projects, almost 936m length of underground utility tunnels at Amundsen-Scott station. It accommodates the piping that conveys fresh water from current well sites, as well as waste water to repositories in abandoned wells. The under snow tunnels allow year-round access for system operations and maintenance.

Investigation for Fire Flow of the Deeply Underground Shin-Gum-Ho Subway Station (대심도 신금호역사의 화재 유동에 대한 고찰)

  • Jang, Yong-Jun;Park, Il-Soon;Kim, Jin-Ho;Jung, Woo-Sung;Kim, Hag-Beom;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.110-115
    • /
    • 2010
  • Recently the deeply underground tunnels have been increased along the subway railroads of urban area compared to the past subway railroads. The Shin-Gum-Ho subway station (the Fifth lines, the depth : 46m) which is the third among the deep subway stations in the Korea was chosen as the model of deeply underground stations, and attempted to do simulation of fire. This station consists of three entrance, the basement first floor (B1), the basement second floor (B2), the basement eighth floor or platform (B8) and escalators and stairs from B2 to B8. The total number of grid was about 9,000,000 to make simulation of fire and smoke from the platform to entrance in this research, and the grid system was divided into 19 blocks to increase the efficiency of this simulation. The FDS (Fire Dynamics Simulation) was chosen to make the simulation of fire, and the model of turbulent flow was LES (Large Eddy Simulation). Each block is processed in a CPU using parallel processing of MPI (Message Passing Interface). The resource of CPU for this simulation is a ten of Intel 3.0 GHz Dual CPU (20 CPU).

  • PDF

Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations (서울시 일부 지하철역 내 부유 진균, 입자상 물질, 이산화탄소의 분포 양상)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.4
    • /
    • pp.325-330
    • /
    • 2006
  • Objectives: The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. Methods: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. Results: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, $PM_{10}\;and\;PM_{2.5}$, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean $PM_{10}\;and\;PM_{2.5}$ concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). Conclusions: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.

Development of Railway Platform Safety Equipment using Laser Radar Sensor (레이저 레이더 센서를 이용한 철도 승강장 안전설비의 개발)

  • Kim, Yoo-Ho;Hwang, Jong-Gyu;Jo, Hyun-Jeong;Baek, Jong-Hyun;Kim, Baek-Hyun;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Many accidents are being occurred due to many missteps, etc. at the railway platform. Recently in Korea, efforts to prevent casualties fundamentally are being made by installing and operating the PSD(Platform Screen Door) with underground station building as its center to prevent these casualties of passengers. Although this PSD can solve the problem of public casualties at platform fundamentally, it is impossible to install it at whole station buildings since its installation cost is high, and in case of the ground station building of general railway whose operation speed is higher, installation of PSD is impossible due to the characteristics of railway system. This paper proposes the novel safety equipment using Laser radar sensors for the prevention against casualties of passengers at station buildings where the PSDs are not installed like this. The safety equipment using Laser radar sensors is the safety equipment making an approaching train stopped if the falling object is a person by detecting the obstacle at platform through, and it has the merit possible to apply it to station buildings not only in the underground section but also in the ground section since it may detect accurately under ambient environmental elements such as the snow, rain and yellow dust, etc. also. We developed the prototype of the safety equipment to reduce public casualties at platform by using Laser radar sensors and carried out its performance test, and the result is presented in this paper.

Characteristics of In-cabin PM2.5 Concentration in Seoul Metro Line Number 2 in Autumn (서울시 지하철 2호선의 가을철 객실 PM2.5 농도의 특성)

  • Shin, Hyerin;Jung, Hyunhee;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.186-191
    • /
    • 2019
  • Objectives: Subway is one of the most common transportation modes in Seoul, Korea. The objectives of this study were to determine characteristics of in-cabin $PM_{2.5}$ concentration in Seoul Metro Line Number 2 and to identify factors of the $PM_{2.5}$ concentration. Methods: In-cabin $PM_{2.5}$ concentrations in Seoul Metro Line Number 2 were measured using real-time monitors and the factors affecting $PM_{2.5}$ concentration in cabin were observed. Linear regression analysis of in-cabin $PM_{2.5}$ concentration and indoor/outdoor (I/O) ratio were performed. Results: In-cabin $PM_{2.5}$ concentration was associated with the in-cabin $PM_{2.5}$ concentration in previous station. In-cabin $PM_{2.5}$ concentration was correlated with ambient $PM_{2.5}$ concentration and associated with underground station with control of the in-cabin $PM_{2.5}$ concentration in previous station. I/O ratio increased as the number of passengers increased and when passing through the underground station with control of I/O ratio in previous station. Conclusion: In-cabin $PM_{2.5}$ concentration was affected by ambient $PM_{2.5}$ concentration. Therefore, management of in-cabin $PM_{2.5}$ concentrations should be based on outdoor air quality.

A Study on Status and Accuracy of Underground Facilities Maps (지하시설물도 현황 및 정확도 분석에 관한 연구)

  • Lee, Yong-Wook;Heo, Min;Lee, Jae-One;Bae, Kyoung-Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2007
  • As the centralization of city, underground facilities is increasing and being more important. Although the importance of underground facilities map has been emphasized, there were many accidents related underground facilities. The inaccuracy of existing data and the carelessness of management caused many accidents. It is very important to update and to have high quality accuracy of underground facilities maps. But the underground facilities maps are mapped and updated by each institutes. So it is difficult to verify the accuracy of the data. In this study, Field Test is performed to analyze the horizontal accuracy of existing maps using Electromegnetic Induction Method, Total Station and GPS. Surveying of underground facilities in Seoul was performed for 6 institutes of underground facilities during 3 years. The aim of this study is to verify the horizontal accuracy of data and to improve the accuracy of underground facility maps. As the result of analysis, the horizontal accuracy of 6 underground facilities management institutes is 73 cm(2004), 78 cm(2005) and 75 cm(2006).

A Study on the Analysis of Positional Accuracy between the GPR Survey Data and Underground Space Integration Map (현장 GPR 탐사자료와 지하공간통합지도 상호위치 정확도 분석에 관한 연구)

  • SONG, Seok-Jin;CHO, Hae-Yong;HAN, Dam-Hye;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.208-216
    • /
    • 2020
  • Recently, issues regarding underground safety such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, raising the need for more accurate management of underground facilities. Thus, this study derived a technique for comparing spatial data of underground facilities acquired from GPR exploration results acquired at the site with spatial data of integrated underground spatial maps. Using this underground space integrated map-linked service prototype program developed through this study, comparing the location information of the GPR exploration results and the underground space integrated map for the verification of site usability in some sections around Gangnam Station, the results demonstrated that the location of the map is 0.879m maximum, minimum of 0.101m and the average fudge factor was 0.625m. If accuracy of the GPR exploration results is guaranteed, it is judged that it can be used to improve the location accuracy of the underground space integration map.

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

Investigation of soil behaviour due to excavation below the grouped pile according to shape of tunnel station (터널 정거장 형상에 따른 군말뚝 하부 굴착 시 지반거동 연구)

  • Kong, Suk-Min;Oh, Dong-Wook;Lee, Jong-Hyen;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.83-97
    • /
    • 2018
  • Tunnels are widely used for special purposes including roads, railways and culvert for power transmission, etc. Its cross-section shape is determined by uses, ground condition, environmental or economic factor. Many papers with respect to behaviours of adjacent ground and existing structure tunnelling-induced have been published by many researchers, but tunnel cross-section have rarely been considered. A collapse of tunnel causes vaster human and property damage than structures on the ground. Thus, it is very important to understand and analyse the relationship between behavoiurs of ground and cross-section type of tunnel. In this study, the behaviour of ground due to tunnel excavation for underground station below the grouped pile supported existing structure was analysed through laboratory model test using a trap-door device. Not only two cross-section types, 2-arch and box, as station for tunnel, but also, offset between tunnel and grouped pile centre (0.1B, 0.25B, 0.4B) are considered as variable of this study. In order to measure underground deformation tunnelling-induced, Close Range Photogrammetry technique was applied with laboratory model test, and results are compared to numerical analysis.