• Title/Summary/Keyword: Underground pipeline

Search Result 160, Processing Time 0.031 seconds

Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline (상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서)

  • Kwak, Pill-Jae;Park, Sang-Hyuk;Choi, Chang-Ho;Lee, Hyun-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

A Study on the Safety Management of High Pressure Underground Pipeline in Industrial estate (산업단지 고압매설배관 안전관리 고찰)

  • Choi, Hyun-Woong;Chung, Se-Kwang;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.30-38
    • /
    • 2017
  • Established in the 1960s, high pressure underground pipelines in Ulsan and Yeosu industrial estate are underground as toxic gas as well as combustible gas that is heavier than city gas and low combustion range. Especially, industrial pipelines occupy more than 20 years old pipes. In this way, the industrial estate pipeline was installed before the introduction of the supervision of construction, However, unlike the city gas pipeline, the pipeline is managed without any legal obligation. In this study, the safety management status of high pressure underground pipelines and urban gas underground pipelines in the industrial estate is analyzed and comparison of laws, extent of damage impact, using the pipe inspection model for pipe inspection of high pressure piping system with the existing piping system. it is intended to cuntribute to improving the safety of industrial estate are underground pipeline.

Standards of Distance between Gas Pipeline and Tower Ground (가스배관과 철탑접지의 이격거리 관련 기준)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • 한국가스학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.191-195
    • /
    • 2006
  • Because of the continuous growth of energy consumption and also the tendency to site gas pipeline and power line along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. The lightning strokes collected by an electric substation or power line tower might cause arcing through the soil to an adjacent gas pipeline. This paper gives the outline of the resistance coupling and the standards of distance between gas pipeline and tower ground.

  • PDF

Analysis of DC Traction Stray Current Interference on Buried Pipelines (지하철 누설전류가 도시가스 배관에 미치는 영향 해석)

  • Lee H.G.;Ha T.H.;Ha Y.C.;Bae J.H.;Kim D.K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1376-1378
    • /
    • 2004
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the cathodic protection systems of buried pipelines and DC traction stray current influence on it using the simulation software CatPro. We can discuss the problems and mitigation of DC traction interference for protected pipeline.

  • PDF

A Fuzzy Inference based Reliability Method for Underground Gas Pipelines in the Presence of Corrosion Defects

  • Kim, Seong-Jun;Choe, Byung Hak;Kim, Woosik;Ki, Ikjoong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.343-350
    • /
    • 2016
  • Remaining lifetime prediction of the underground gas pipeline plays a key role in maintenance planning and public safety. One of main causes in the pipeline failure is metal corrosion. This paper deals with estimating the pipeline reliability in the presence of corrosion defects. Because a pipeline has uncertainty and variability in its operation, probabilistic approximation approaches such as first order second moment (FOSM), first order reliability method (FORM), second order reliability method (SORM), and Monte Carlo simulation (MCS) are widely employed for pipeline reliability predictions. This paper presents a fuzzy inference based reliability method (FIRM). Compared with existing methods, a distinction of our method is to incorporate a fuzzy inference into quantifying degrees of variability in corrosion defects. As metal corrosion depends on the service environment, this feature makes it easier to obtain practical predictions. Numerical experiments are conducted by using a field dataset. The result indicates that the proposed method works well and, in particular, it provides more advisory estimations of the remaining lifetime of the gas pipeline.

Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines (전력선 접지와 매설배관의 이격거리 실증실험 사례 조사)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF

Conceptual Design for Underground Hydrogen Pipeline Monitoring System: Case Study on Fiber Optic Sensing (지하매설 수소 배관망 안전 모니터링 시스템의 개념 설계: 광섬유 기반 모니터링 사례를 중심으로)

  • Park, Jae-Woo;Yeom, Dong-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.673-686
    • /
    • 2022
  • Recently, as the importance of eco-friendly energy has increased hydrogen gas is in the spotlight as future energy. Due to its special properties, hydrogen gas is more difficult to detect requiring more precise sensing technology. The primary objective of this study is to design a concept of an underground hydrogen pipeline monitoring system. For this, the following research works are conducted sequentially; 1)selection of core technology for conceptual design, 2)state-of-the-art review, 3)design of a concept of the system. As a result, DAS(Distributed Acoustic Sensing), and DTS(Distributed Temperature Sensing) are selected as each core technology. Furthermore, a conceptual design of an underground hydrogen pipeline monitoring system is deducted. It is expected that the impact on the eco-friendly energy industry will be enormous due to the increasing interest in using hydrogen energy.

Permanent Ground Deformation induced by Christchurch Earthquake and Estimation of Underground Water Pipeline Performance in New Zealand (뉴질랜드 크라이스트처어치 지진에 의해 발생된 영구지반변형과 매설된 상수도관 성능평가)

  • Jeon, Sang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4201-4207
    • /
    • 2015
  • In this study, the performance of underground water pipeline system affected by earthquakes is examined by using data acquired after MW 6.2 February 22, 2011 earthquake in Christchurch, NZ. Water pipeline repair rates, expressed as repairs/km, for different types of pipe are evaluated inside the areas of which liquefaction induced by permanent ground deformation was observed and assessed relative to differential settlement and lateral ground strain, calculated from high resolution LiDAR data acquired before and after each seismic event. The earthquake performance of underground water pipeline systems associated with permanent ground deformation is summarized in this paper. The results show that highly ductile polyethylene water pipelines has a high earthquake performance.

Influence on Lead Wire Method of Distributed ICCP Systems for Mitigation of DC Traction Interference (전철 간섭 대책용 분포형 외부전원시스템의 배관인출 방법에 따른 영향)

  • Lee, H.G.;Ha, Y.C.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.282-284
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on lead wire method of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF