• Title/Summary/Keyword: Underground life space

Search Result 80, Processing Time 0.024 seconds

Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space (지하생활공간 화재시 풍속에 따른 열유동 특성 연구)

  • Kim, Young-No;Suk, Chang-Mok;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study analyzes heat flows and fire behavior through a reduced-scale model experiments about change of wind velocity in underground life space. When the wind velocity is increased the temperature rise time of the fire room was risen fast. And temperature of fire room was increased. And increase of wind velocity displayed maximum temperature at an opening of the fire room. Heat flows by fire spread increase size of smoke occurrence and flame, and displayed high temperature distribution in passageway than inside of neighborhood department promoting eddy flow spread as wind velocity increases. Finally, heat flows are decided by wind and wind velocity at fire of underground life space, and Wind velocity increases, temperature increase and decrease could confirm that is gone fast.

A study about caculating the heating load of the wall of underground space to be used undereground temperature (지중온도를 이용한 지하공간 벽체의 난방부하 계산에 관한 연구)

  • Jeong, Soo-Ill
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • The energy crisis is culminating for the life of the fossil fuel in the future which is come to end at $30{\sim}40$ years. Moreover above 90% of the energy in our country depend on importing and the crisis is more seγious than it of other countries. So architects devote low energy house research and it means underground space research have become public opinion. But there is not an accurate and utility method calculating the heating load of underground space. In this study it is proposed that the heating load is calculated by setting adiabatic thichness of soil and predicting underground temperature. The prediction of the underground temperature is calculated by the latitude, the level, the distance from sea, the condition of earth surface.

Optimum Structural Planning of the Underground Space Utilization in the Long-Life Housing (장수명주택의 지하공간활용 최적화 구조계획기법)

  • Kang, Ji-Yeon;Kim, Hyung-Geun;Jo, Min-Joo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • The objective of this paper is to suggest structural design for the long-life housing apartment complex to save the construction cost. The key is to use unavailable underground space due to bearing walls or bad configuration of columns in apartments as the parking space. Therefore, the structural plan of apartment buildings considering the parking section in the underground should be designed. After analytical resutls of three cases, it is significant effect in saving construction cost.

Research on Improving Quality Management for Underground Space Integration Map - Focusing on pipe-type underground facilities - (지하공간통합지도 품질관리 개선방안 연구 - 관로형 지하시설물을 중심으로 -)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.2
    • /
    • pp.221-235
    • /
    • 2020
  • The development and utilization of underground spaces are increasing as the use of land based on ground surface became limited due to rapid urbanization triggered by population growth and industrialization. Despite its merit of efficient use of limited land and space, it may contribute to occurrence of various disasters such as sinkholes and damage to underground facilities. After the sinkholes formed and occurred across the country in 2014, there has been an effort to establish Underground Space Integration Map containing 15 types of underground information. Still, there is an increasing demand to improve the quality of underground information stemmed from continuation of such events including the rupture of the hot water pipe in Goyang-si and the fire in the KT site in Ahyeon-dong, Seoul. Hereby, with the aim to improve the quality of Underground Space Integration Map, this study analyzes quality standards, regulations, and guidelines related to spatial data to improve quality inspection standards and methods included in the production rules for the Underground Space Integration Map. In particular, it suggests improvement plan for data quality management for pipe-type underground facilities, known as lifelines, which are essential part of daily life of the citizens, and the largest cause for accidents according to 15 types of underground information managed through the Underground Space Integration Map.

The Design of a Retrieval System for Management of Emergency Equipment in the Underground Space (지하 공간의 방재장비 관리를 위한 검색 시스템 설계)

  • Park, Myung-Gil;Shin, Seong-Hyun;Jung, Hyun-Goon;Kim, Chang-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.641-644
    • /
    • 2008
  • Recently, a lot of life damage caused by disaster have happened in the underground space. Because the space is closed areas and used by the unspecific majority. Therefore there are many kinds of emergency equipments for diminishing the life damage in case of the disaster. In this paper, we propose the retrieval system for the administrator. Our system provides the function for searching the descriptive information and spatial information of the equipment management. And the administrator can manage underground disaster equipments effectively through the system.

  • PDF

A study on the application and construction of a rainwater storage tank in apartment complex (공동주택단지에서의 빗물저수조 설치 및 활용방안 연구)

  • Lee, Won-Yeul;Jeong, Sang-Min;Shin, Duck;Lee, Chuel-Hun;Han, Moo-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.4 s.18
    • /
    • pp.165-171
    • /
    • 2005
  • Nowadays, a source of all water, which has been spent by a lot of people, is the rainwater The rainwater is directly relating human being' life. According to how to use rainwater. human being' life is abundant or poor. Due to the lack of underground filtration quantity, the water circulation of the city is discontinued and the underground ecosystem is destroyed. This study suggest that the unused underground space of building and temporary structure can be used into rainwater storage tank in the facility to use rainwater. Moreover, in this study, while the building is constructed, It is showed that the water used in construction can be replaced in the rainwater.

A study on the fire smoke diffusion delay strategy in a great depth underground double deck tunnel junction (대심도 복층터널 교차로 화재연기 확산지연 방안 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek;Han, Jae-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.115-126
    • /
    • 2019
  • Recently, in order to solve the traffic congestion in urban areas and to improve the peripheral environment, research on the design and construction technology development of great depth underground double-deck tunnel is under way by using the underground space in the urban area. The network type double-deck tunnel is in the form of an intersection with a small cross section and a steep slope as per construction at the base of a flatland, so that the fire smoke spreads rapidly in case of fire, which is expected to cause damage of human life. Therefore, this study is analyzed the delay effect of fire smoke diffusion according to the installation and non - installation of delay system for fire smoke diffusion at the intersection. Fire fumes were delayed up to 270 seconds when the delay system for fire smoke diffusion was installed at the intersection and it is analyzed that the greater the operating area of the delay system for fire smoke diffusion, the more preventable the damage of human life of the intersection.

A study on the regulation of durability standard of underground structures monitoring sensors (지하구조물 계측센서의 내구연한 기준에 대한 규정 분석 연구)

  • Woo, Jong-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.73-81
    • /
    • 2018
  • The purpose of this study is to research the regulation of durability standard of underground structures monitoring sensors. The durability criteria for construction monitoring sensors of domestic construction companies, the standard years of contents such as buildings on the income tax implementation regulations, and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. The durability criterion on products such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the underground structure, is 8 to 10 years. It is considered that the monitoring sensor installed in the paperboard and the concrete structure at the time of construction will have considerably shortened service life rather than the useful life of the product itself due to various adverse factors such as groundwater influence and compaction.

Research on the direction of laws improvement integrated maps of underground space for systematic management (지하공간통합지도의 체계적인 관리를 위한 제도 개선 방향 연구)

  • Jisong RYU;Yonggu JANG;Donghyun PARK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.17-26
    • /
    • 2023
  • The integrated underground space map is a three-dimensional map that integrates 16 types, including 7 types of underground facilities, 6 types of underground structures, and 3 types of ground. In order to systematically construct, manage, and utilize the integrated underground space map, it was institutionalized as the "Special Act on Underground Safety Management," and the "Underground Space Integrated Map Production Work Regulations" was prepared as detailed work regulations. However, there is a lack of institutional mechanisms to develop new technologies such as the completed book submission system for submitting change information and automation technology for updating the integrated underground spatial map and to expand the usability of the integrated underground spatial map. Accordingly, this study examined the current status of the integrated underground space map and attempted to suggest a direction for improving the current system through a revision plan and detailed operation management regulations (draft) of the Special Act on Underground Safety Management.