• Title/Summary/Keyword: Underground cavern

Search Result 173, Processing Time 0.019 seconds

Estimation of Water Leak Rate in the Underground Oil Storage Cavern (지하 원유 저장공동에서의 누수량 산정에 대한 연구)

  • Shim, Hyun-Jin;Park, Tae-Jun;Jeong, Woo-Cheol;Kim, Ho-Yeong;Choi, Young-Tae
    • Tunnel and Underground Space
    • /
    • v.20 no.4
    • /
    • pp.233-240
    • /
    • 2010
  • Double Plug is constructed for preventing mixing of two different oils between two compartments in the underground oil storage cavern. And the gas and oil tightness of double plug is tested from the measurement of water leakage from double plug after the completion of double plug water filling. If water leakage is underestimated, it can increase construction cost and if water leakage is overestimated, it can increase operating cost. Therefore, optimum water leakage should be estimated to cut down the cost. In this study, hydraulic stability analysis was conducted to consider permeable properties of rock mass around double plugs and a water leak rate from double plug was estimated from the hydraulic stability analysis and case study. Finally, the reliability of estimation of water leak rate was proven by comparing estimated water leak rate with measured data.

Simulation of Two-Phase Fluid Flow in a Single Fracture Surrounding an Underground LPG Storage Cavern: II. Verification of Numerical Model and Field Application (지하 LPG 저아공동에 인접한 단일절리에서의 이상유체거동해석: II. 수치모형의 검증 및 적용)

  • Han, Il-Yeong;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • In order to verify the numerical model, which was developed to simulate the behavior of the two-phase fluid flow in a single fracture, the characteristic equation of relative permeability was incorporated into the developed numerical model, and the computed results were compared with the experimental results of the model test. As results of the sensitivity analysis on the roughness and the aperture size of fracture, the gas velocity was inversely proportional to the fracture roughness, and not proportional to the square of aperture size which is usually observed in single phase flow in a single fracture. The numerical model was applied to the underground LPG storage terminal in order to check the field applicability. The simultaneous flow of water and gas in accordance with the operation pressures in a single fracture near cavern was simulated by the model. It was shown that the leaked gas was able to be controlled in a single fracture neither by the pressure of operation nor by that of groundwater in case the fracture became smoother in roughness and smaller in aperture size.

  • PDF

The Estimation of Temperature distribution around Gas Storage Cavern (저온가스 저장공동 주위암반의 온도분포 예측에 관한 연구)

  • Lee, Yang;Lee, Seung-Do;Moon, Hyun-Koo
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • As underground caverns have many advantages such as safety and operation, they can also be used for gas storage purpose. When liquefied gas is stored underground, the cryogenic temperature of the gas affects the stability of the storage cavern. In order to store the liquefied gas successfully, it is essential to estimate the exact temperature distribution of the rock mass around the caverns. The main purpose of this study is the development of theoretical solution to be able to estimate the temperature distribution around storage caverns and the assessment of the solution. In this study, a theoretical solution and a conceptual model for estimating two and three dimensional temperature distribution around the storage caverns are suggested. Based on the multi-dimensional transient heat transfer theory, the theoretical solution is successfully derived by assuming the caverns shape as simplified geometry. In order to assess the theoretical solution, by performing numerical experiments with this multi-dimensional model, the temperature distribution of the theoretical solution is compared with that of numerical analysis. Furthermore, the effects of the caverns size are investigated.

Hydrogeological Characteristics of Seawater Intrusion in the Coastal Area (임해지역 주변에서의 해수침투특성)

  • 김천수;김경수;배대석;송승호
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.61-72
    • /
    • 1997
  • With increasing activities for groundwater withdrawal and for the construction of underground cavern in the coastal areas, the seaward flow of groundwater has been disturbed or even reversed, resulting in seawater intrusion in aquifers. This phenomenon would be attributed to the freshwater contamination and the corrosion of steel materials. The hydrogeological and geochemical investigations have performed to characterize the seawater intrusion into the underground caverns located in the coastal area. Assumimg the inland aquifer as unconfined one, we have found out that the theoretical interface of freshwater-seawater is far different from the pathways identified. In the study site, the main pathways of seawater intrusion into the underground cavern are characterized as the sub-horizontal fractures (zones). The seawater intrusion in granitic terrane would depend mainly on the characteristics of conductive fracture system developed along the coastal area.

  • PDF

Thermohydromechanical Behavior Study on the Joints in the Vicinity of an Underground Disposal Cavern (심부 처분공동 주변 절리에서의 열수리역학적 거동변화)

  • Jhin wung Kim;Dae-seok Bae
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.171-191
    • /
    • 2003
  • The objective of this present study is to understand long term(500 years) thermohydromechanical interaction behavior on joints adjacent to a repository cavern, when high level radioactive wastes are disposed of within discontinuous granitic rock masses, and then, to contribute this understanding to the development of a disposal concept. The model includes a saturated discontinuous granitic rock mass, PWR spent nuclear fuels in a disposal canister surrounded with compacted bentonite inside a deposition hole, and mixed bentonite backfilled in the rest of the space within a repository cavern. It is assumed that two joint sets exist within a model. Joint set 1 includes joints of $56^{\circ}$ dip angle, spaced 20m apart, and joint set 2 is in the perpendicular direction to joint set 1 and includes joints of $34^{\circ}$ dip angle, spaced 20m apart. The two dimensional distinct element code, UDEC is used for the analysis. To understand the joint behavior adjacent to the repository cavern, Barton-Bandis joint model is used. Effect of the decay heat from PWR spent fuels on the repository model has been analyzed, and a steady state flow algorithm is used for the hydraulic analysis.

Stochastic Finite Element Analysis of Underground Rock Cavern Using Monte Carlo Simulation Techinque (몬테칼로 시뮬레이션기법을 이용한 지하암반동굴의 확률론적 유한요소해석)

  • 최규섭;심재구;정영수
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.301-308
    • /
    • 1995
  • In this study, a stochastic finite element method is proposed with a view to consider rock property variations in the analysis of structural behavior on underground caverns. Here, the Monte carlo simulation technique, which has been widely used in probabilistic applications in many engineering fields, is applied for the analysis of the effect rock property distribution. Using the newly developed computer program based on the above - mentioned method, the underground opening in biaxial stress field is analyzed considering the effect of material property variation.

  • PDF

Planning, design and construction of the cavern arena: Heating, Ventilation and Air Conditioning (GJOEVIK올림픽 경기장(난방 및 환기분야))

  • Mathisen, Hans-Martin;Lee, D.W.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.10b
    • /
    • pp.213-218
    • /
    • 1993
  • The paper deals with problems connected with heating and ventilation of underground premises for public use. Some properties of rock and special problems connected with designing ventilation systems for underground spaces are first briefly discussed. The rest of the paper deals with design of ventilation and heating systems. The conclusion is that there are no large problems with heating and ventiliation of underground premises, but there are still problems connected with for instance thermal properties of rock when water flows in the cracks. An optimum design demands better knowledge of these properties.

  • PDF

Temperature change around a LNG storage predicted by a three-dimensional indirect BEM with a hybrid integration scheme

  • Shi, Jingyu;Shen, Baotang
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.309-317
    • /
    • 2018
  • We employ a three-dimensional indirect boundary element method (BEM) to simulate temperature change around an underground liquefied natural gas storage cavern. The indirect BEM (IBEM) uses fictitious heat source strength on boundary elements as basic variables which are solved from equations of boundary conditions and then used to compute the temperature change at other points in the considered problem domain. The IBEM requires evaluation of singular integration for temperature change due to heat conduction from a constant heat source on a planar (triangular) region. The singularity can be eliminated by a semi-analytical integration scheme. However, it is found that the semi-analytical integration scheme yields sharp temperature gradient for points close to vertices of triangle. This affects the accuracy of heat flux, if they are evaluated by finite difference method at these points. This difficulty can be overcome by a combination of using a direct numerical integration for these points and the semi-analytical scheme for other points distance away from the vertices. The IBEM and the hybrid integration scheme have been verified with an analytic solution and then used to the application of the underground storage.

Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam (전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성)

  • Lee, Jin-Yong;Choi, Mi-Jung;Kim, Hyun-Jung;Cho, Byung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.33-44
    • /
    • 2009
  • Water curtain of an underground LPG storage cavern is a facility to prevent leakage of high pressure gases, for which groundwater should flow freely towards the cavern and groundwater level also must be stably maintained. In this study, in order to evaluate qualities of seepage water and surrounding groundwater of an underground LPG storage cavern in Yeosu, 4 rounds of samplings, field measurements and laboratory analyses (February, May, August, October of 2007) were conducted. According to field measurements, pH was weak acidic to neutral but it gradually increased with time. Electrical conductivity (EC) of groundwater near a salt stack showed very high values between 10.47 and 38.50 mS/cm. Dissolved oxygen (DO) showed a very wide range of 0.20~8.74 mg/L and a mean of oxidation-reduction potential (ORP) was 159 mV, which indicated an oxidized condition. Levels of $Fe^{2+}$ and $Mn^{2+}$ were mostly less than 3 mg/L. All of seepage waters showed a Na-Cl type while only groundwater near the salt stack showed a Na-Cl type with a high total dissolved solid. The other groundwaters exhibited typical $Ca-HCO_3$ types. Levels of aerobic bacteria were mostly very high (573-39,520 CFU/mL). Based on the analyses of these hydrochemistry and biological characteristics, it is concluded that there are no particular problems in groundwater and seepage water, which not causing a trouble in the cavern operation. However, both for control of bio-clogging and for sustainable operation of the water curtain system, a regular hydrochemical and microbiological monitoring is required for the seepage water and surrounding groundwater.

A numerical study on pull-out behaviour of cavern-type rock anchorages (수치해석에 의한 암반상의 지중정착식 앵커리지 인발 거동 연구)

  • Hong, Eun-Soo;Cho, Gye-Chun;Baak, Seng Hyoung;Park, Jae-Hyun;Chung, Moonkyung;Lee, Seong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.521-531
    • /
    • 2014
  • This paper is a study for behaviour of cavern type anchorage tunnels for suspension bridges with cable tension. Anchorage behaviour, design method for anchorage, and failure surface angle, ${\delta}$ are analyzed by comparing numerical analysis results and ultimate pullout capacities($P_u$) using bilinear corelation equation. Results show that design depths for cavern type anchorage tunnels are easily checked with linear relationships for $P/{\gamma}/H$ vs. displacement and $P_u/{\gamma}/H$ vs. H/b. The analysis results of maximum shear strain distribution and plastic status show that failure shapes are closer to circular arc model than soil cone model which frequently used. To an easy calculation of the ultimate pullout capacity, we propose a simple bilinear failure model in this study. The calculated ultimate pullout capacities from the proposed bilinear corelation equation using two failure angles results are similar to the ultimate pullout capacities from numerical analysis.