• 제목/요약/키워드: Underground air pollution

검색결과 57건 처리시간 0.029초

복합발전플랜트 내의 가스 화재 거동에 관한 수치해석 (Numerical Study of Fire Behavior Induced by Gas Leakage in Combined Cycle Power Plant)

  • 박재용;성건혁;이용남;최진욱;김대중;이성혁;유홍선
    • 한국분무공학회지
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2015
  • To date, the demand for Combined Cycle Power Plant (CCPP) has been continuously increased to overcome the problem of air pollution and lack of energy. In particular, the underground CCPP is exposed to substantial fire and explosion risks induced by gas leakage. The present study conducted numerical simulations to examine the fire behavior and gas leakage characteristics for a restricted region including gas turbine and other components used in a typical CCPP system. The commercial code of FLUENT V.14 was used for simulation. From the results, it was found that flammable limit distribution of leakage gas affects fire behavior. Especially, the flame is propagated in an instant in restricted region with LNG gas. In addition, consequence analysis factors such as critical temperature and radiation heat flux are introduced. These results would be useful in making the safety guidelines for the underground CCPP.

환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 - (A Study on the Consciousness of the Environment Pollution Problem in Pohang City)

  • 하영길;박경민;권영숙
    • 농촌의학ㆍ지역보건
    • /
    • 제21권1호
    • /
    • pp.61-73
    • /
    • 1996
  • 본 조사는 포항시민의 환경에 대한 인식과 환경오염실태를 조사 분석하여, 이를 통하여 포항시의 환경정책을 펴 나가는 데 기초자료로 활용할 목적으로 읍 면 동의 시청업무 당당 공무원의 면담조사를 통하여 1995년 9월 6일부터 9월 20일까지 포항지역에 거주하고 있는 만 20세이상의 남여 1,059명을 대상으로 하였다. 통합포항시의 가장 중요한 당면문제는 응답자의 47.3%가 교통문제를 꼽고 있으며 다름으로 환경문제가 22.7%, 문화시설문제 11.6%, 식수문제 9.9% 교육문제 5.1%, 민생치안문제 2.1% 순으로 나타났다. 환경오염 책임에 대한 질문에서 응답자의 55.1%가 시민각자에게 책임이 있다고 대답했다. 가정에서 배출되는 쓰레기중 음식물 쓰레기 48.1%, 문화생활 쓰레기 21.8%, 재활용가능 쓰레기 15.6%, 1회용품 14.5% 순으로 나타났다. 규격봉투를 사용시 불편한 점은 66.9%가 봉투가 잘 찢어지는 재질에 문제가 있다고 했다. 수도물에 대한 이상 경험 조사에서 '이물질발생'과 '앙금이 생긴다'가 가끔 또는 자주 있다고 반응했다. 현재 식수로 사용하고 있는 실태를 조사한 결과 약수를 떠와서 마시는 사람이 45.9%로 가장 않았고, 수도물 26.7%, 지하수 17.0%, 생수(사서 마심) 9.3% 순으로 나타났다. 포항시의 공기오염원에 대한 조사에서 78.0%가 포항제철을 비롯한 연관단지를 들고 있으며, 16.6%가 자동차 매연 및 가스, 공사장 먼지 1.7% 순으로 나타났다. 남구지역은 호흡 장애가 더 많았고, 북구지역은 시야방해, 악취발생피해가 유의하게 높았다(P<0.05). 포항시의 수질오염의 주원인에 대해서, 공장폐수 56.2%, 가정하수 36.4%, 축산폐수 5.6% 순으로 나타났다. 북구지역 남구지역은 자동차소음, 남구지역은 오후에 공장과 항공기 소음 공해를 호소했다(P<0.05).

  • PDF

Municipal solid waste management in India - Current status, management practices, models, impacts, limitations, and challenges in future

  • Jagriti Patel;Sanskriti Mujumdar;Vijay Kumar Srivastava
    • Advances in environmental research
    • /
    • 제12권2호
    • /
    • pp.95-111
    • /
    • 2023
  • Pollution, climate change, and waste accumulation are only some of the new problems that have arisen because of the exponential population growth of the past few decades. As the global population expands, managing municipal solid trash becomes increasingly difficult. This is by far the most difficult obstacle for governments to overcome, especially in less developed nations. The improper open dumping of trash, which is causing mayhem across the country, has two immediate effects: it contaminates groundwater and surface water. Air pollution and the accumulation of greenhouse gases are both exacerbated by the release of methane and other harmful waste gases. Leachate from the landfill leaks underground and pollutes groundwater. In most cases, leachate moves into the groundwater zone and pollutes it after forming in association with precipitation that infiltrates via waste. This has far-reaching effects on people's health and disturbs the natural environment. This review article critically examines the current state of Solid Waste Management (SWM), addressing both the highlighted concerns and the government management solutions that have been put in place to address these issues. In addition, the constraints, and difficulties that India will face in the future in terms of solid waste management and the role of models for such a system are discussed.

광섬유센서를 이용한 쓰레기수송관로 유지관리 모니터링에 대한 연구 (The Study about Control Monitoring of Fiber Optic Sensor on Vacuum Pipeline for Waste Collecting System)

  • 이준영;김채석;김봉규
    • 한국유체기계학회 논문집
    • /
    • 제13권2호
    • /
    • pp.54-58
    • /
    • 2010
  • The most recent, Vacuum Pipeline for Waste Collecting System, to collect MSW(Municipal Solid Waste) efficiently, is used environmental preservative, to emit less air pollution, in New City. However, it is difficult to monitor broken pipe and filled mass of Waste, because Vacuum Pipeline is laid underground. Therefore, FBG, optical fiber sensor, is used to inspect the temperature change and longitudinal strain to take proper action for unusual situation. I have need to accumlate sensor data of district control. I hope to be used Vacuum Pipeline more than 30 years in New City.

파쇄 폐타이어를 이용한 반응벽체에 관한 연구: 폐타이어 내의 MTBE(Methyl tertiary Butyl Ether) 흡착 중심

  • 박상현;이재영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.176-179
    • /
    • 2003
  • Fuel oxygenates, such as Methyl tertiary Butyl Ether (MTBE) is additive in gasoline used to reduce air pollution. Gasoline components and fuel additives can leak form underground storage tanks. MTBE is far more water soluble than gasoline hydrocarbons like BTEX then it travels at essentially the same velocity as groundwater. MTBE in drinking water causes taste and odor problems. Therefore, the purpose of the this study is to examine the ability of ground rubber to sorb MTBE form water. The study consisted of running both batch and column tests to determine the sorption capacity and the flow through utilization efficiency of ground rubber. The result of Column test indicate that ground tire rubber has on the 36% utilization rate. Finally, it is clear that ground rubber present an attractive and relatively inexpensive sorption medium for a MTBE. The Author thought that to determine the economic costs of ground rubber utilization, the cost to sorb a given mass of contaminant by ground rubber will have to be compared to currently accepted sorption media.

  • PDF

도시철도 차량기지의 기반녹화에 적합한 방수시스템 선정을 위한 환경 조건 분석 (Analysis of Field Condition for Proper Waterproofing Materials applied to Green Roof System for Depot)

  • 민광만;권시원;최성민;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.127-131
    • /
    • 2006
  • Depot have a lagged behind structure in the side of building up the view. With this reason, people have been recognized depot as hatred facility causes to have car noise, air pollution. In the other hand, depot become a underground and complex facility as a higher-value added building, and moreover, it need to understand the environment that depot structure have a specific field condition to apply green roof system. 1) Analysis proper waterproofing material and root barrier apply to depot need root penetrating test method 2) Suggest root barrier and waterproofing material relate to maintain and construction for green roof system 3) Construction condition for depot have crack movement of structure by vehicle vibration and root penetrating force by plant growth

  • PDF

서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발 (Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map)

  • 이은선;박민빈;이태정;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

복층터널의 분기터널 굴착에 따른 기존터널의 안정성 분석 (Stability analysis of an existing tunnel due to the excavation of a divergence tunnel emerging from double-deck tunnel)

  • 김한얼;김정주;이재국;유한규
    • 한국터널지하공간학회 논문집
    • /
    • 제19권5호
    • /
    • pp.779-797
    • /
    • 2017
  • 최근 도심지의 지상교통시설이 포화수준에 이르렀을 뿐만 아니라 증가하는 교통량으로 인한 교통난과 미세먼지 등의 대기환경 오염의 심화로 인하여 지하도로건설이 각광을 받고 있다. 지하도로건설은 도심지 교통난 해소와 더불어 친환경적인 도시설계가 가능하기 때문에 신설도로 뿐만 아니라 기존도로 역시 지하화 되어 가는 추세이다. 지하도로건설시 IC(분기점)와 JC(나들목) 역할을 수행하는 분기터널의 건설은 필수적이라 할 수 있다. 따라서 분기터널에 의한 기존터널의 영향분석은 필수적으로 고려해야한다. 본 연구에서는 분기터널 굴착 시 기존터널에 미치는 영향을 수치해석을 통해 분석하였다. 분기터널을 기존터널의 직하부를 기점으로 하여 시계방향으로 $45^{\circ}$간격으로 총 5가지의 경우를 설정하였으며, 각각의 경우에서 변위조절방법(Displacement Controlled Model)을 이용하여 지반손실률을 0.5%, 1.0% 그리고 1.5%을 적용하여 수치해석을 실시하였다. 그 결과, 지반손실률이 증가할수록 변위와 파괴범위, 그리고 안정성에 미치는 영향이 증가하는 것으로 나타났다. 또한 직하부에 위치한 분기터널이 가장 안정성에 취약한 것으로 확인 되었으며, 분기터널의 위치가 연직, 수평방향에 있을 경우보다 대각선방향에 위치할 경우가 변형과 라이닝 파괴 측면에서 불안정한 것으로 나타났다.

미세먼지 저감을 위한 특허기술들 (Patent Technologies for Reducing Micro-Dust)

  • 조태준;김태수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-14
    • /
    • 2020
  • 필터가 장착 된 먼지 감소 팬을 포함하여 새로운 유형의 Composite Cyclone Scrubber를 개발하고, 목표 설치 및 유지 보수 비용에 대해서는 기존 도로 오염 저감 시스템 대비 64 %의 투자비 절감 (61 억 원 vs. 170 억 원), 기존 도로 오염 저감 조치 (72.6 억 원) 대비 사회적 비용편익이 43 % 증가, 50.8 억 원)가 예측되고 있다. 장치의 구성은 송풍기 형 나선형 가이드 베인이며, 분사 압력은 미세먼지를 포집한다. 분사 각도 및 접촉 범위가 다양한 노즐, 스프레이 액체 등과 순환 수를 이용한 스프레이이며, 분사 된 물이 Guide Vane과 45도 각도로 충돌로 인해 오염된 가스를 만나기 때문에 41.4 % 더 많은 미세 먼지를 포집한다. 이는 기존의 집진기보다 141 % 증가한 것이다. 포집 액체, 순환 빗물 및 우물 공급원과 관련하여 우리는 특허에서 막대한 양의 에너지와 경제적으로 절약되는 친환경 시스템을 기대한다. 가이드 베인 및 금속 필터는 90 % 이상의 미세 먼지를 줄였으며, 분무 된 물은 베인과 필터를 청소하여 유지 관리 예산을 최소화했다. 개발 된 설계의 예비 평가를 통해 특징적인 물분사로 인하여 유지 보수 예산을 줄일 수 있다.

서울 시내 일부 주차장의 공기중 섬유농도에 영향을 미치는 인자 분석 (The Factor Analysis of Airborn Fiber Concentrations at Parking Lots in Seoul)

  • 문지영;김현욱
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.157-167
    • /
    • 1994
  • This study was conducted to analyze the relationship between the types of fiber and its content and the levels of airborne fiber concentrations at eight parking lots where sprayed insulation material was found on the walls and ceilings. Also this study was designed to find the relationship between the levels of airborne fiber concentrations and such variables as air current, humidity, total exhaust volume, surface condition of insulation material and building age. The results obtained were as follows : 1. No significant correlation was found between the levels of airborne tiber concentration and the building age, air current, humidity, total exhaust volume, space and the number of traffics. 2. A significant correlation was found between the levels of airborne fiber concentration and the MMMF content of the insulation material(r=0.7594). However, no significant correlation was found between the levels of airborne fiber concentration and total fiber content of insulation material. 3. The differences of the airborne fiber concentrations among Cateogory 1, 2 and 3 classified by the degrees of surface insulation material maintenance were very significant. 4. Two bulk samples contained 30% crodicolite and 1% anthophylite. The MMMFs, in all parking lots, included mineral wool, cellulose fiber, trace cellulose fiber, trace tiber glass and vermiculite. 5. The mean value and the range of airborne fiber concentrations at 8 parking lots were $0.0239{\pm}0.0095f/cc$ and 0.0054-0.0447 f/cc, respectively. The fiber concentrations of 35 out of 38 samples(92%) were over 0.01 f/cc which is the Environment Administration's recommended asbestos level for the underground space. This study suggests that most of building insulation materials used in Korea, contain MMMF and sometimes asbestos. Currently, MMMF pollution levels may exceed the Environment Administration's recommended level for underground space. It has been found that airborne fiber concentrations increased significantly with MMMF content and with the maintenance condition of surface material. Therefore, it is recommended that a proper management technique should be developed and immediately implemented since the conditions of surface material will be gradually deteriorated due to building age and usage. Since health hazards of the MMMF, similar to those of asbestos, are being gradually acknowledged, a proper management technique which is applicable to control total airborne fiber concentrations, both asbestos and MMMF, be developed and an acceptable indoor air standard be promulgated as early as possible.

  • PDF