• 제목/요약/키워드: Underground Facility Survey

검색결과 29건 처리시간 0.027초

상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구 (A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류 (Pattern Classification of Volatile Organic Compounds in Various Indoor Environment)

  • 김윤신;노영만;이철민;김기연;김종철;전형진
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.

경주 방폐장의 불균질 배경 단열의 정량화 (Quantification of Heterogenous Background Fractures in Bedrocks of Gyeongju LILW Disposal Site)

  • 조현진;정재열;임두현;함세영
    • 지질공학
    • /
    • 제27권4호
    • /
    • pp.463-474
    • /
    • 2017
  • 본 연구는 화강암과 퇴적암지역에 위치하는 중저준위 경주방폐장의 불균질 배경 단열의 방향성, 밀도, 크기를 정량적으로 분석하였다. 불균질 배경 단열을 분석하기 위하여 지표지질조사, 전기비저항탐사, 공내 초음파주사검층 자료를 이용하였다. 연구지역 배경 단열의 정량화 분석을 위해서 부트스트랩 방법을 적용하였으며, 이에 의하여 위치에 따라 다양한 방향성을 가지는 단열들의 이방성을 합리적으로 특성화할 수 있었다. 단열 밀도는 단층 연장성을 고려한 단층거리의 역산값 및 전기비저항 평균값과 상관성을 보였으며, 평균 부피 단열 밀도($P_{32}$)는 $3.1m^2/m^3$로 나타났다. 중저준위 방폐물 처분 지하 사일로에서 측정된 단열과 지표 단층 정보에 의하면, 단열크기는 단열의 프랙탈 성질에 기초한 멱함수 법칙 분포에 따르며, 배경 단열의 반경은 1.5~86 m로 산정되었다.

지속가능 온실 냉난방을 위한 강변여과수 취수 및 회수시스템 개발 (Development of Riverbank Filtration Water Supply and Return System for Sustainable Green House Heating and Cooling)

  • 조용;김대근;김형수;문종필
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.20-29
    • /
    • 2012
  • The green house on the waterfront is air-conditioned by a water-source heat pump system with riverbank filtration water. In order to supply riverbank filtration water in alluvium aquifer, the riverbank filtration facility for water intake and recharge, two pumping wells and one recharge well, has been constructed. The research site in Jinju, Korea was chosen as a good site for riverbank filtration water supply by the surface geological survey, electrical resistivity soundings, and borehole surveys. In the results of two boreholes drilling at the site, it was revealed that the groundwater table is about 3 m under the ground, and that the sandy gravel aquifer layer in the thickness of 6.5 m and 3.5 m occurs at 5 m and 7 m in depth below the ground level respectively. To prevent the recharge water from affecting the pumped water which might be used as heat source or sink, the distance between pumping and recharge wells is designed at least 70 m with a quarter of recharged flow rate. It is predicted that the transfer term, the recharge water affects the pumping well, is over 6 months of heating season. Hydrogeological simulation and underground water temperature measurement have been carried out for the pumping and recharge well positions in order to confirm the capability of sustainable green house heating and cooling.

실내공적공간의 공공성에 관한 연구 (A Study on Public Needs for Privately Owned Public Space)

  • 윤지혜;김정곤
    • 한국실내디자인학회논문집
    • /
    • 제15권5호
    • /
    • pp.157-166
    • /
    • 2006
  • Recently, it appears several counterproposals about desirable figures of urban architecture. All of them proposes 'publicity' with cohernt tendency. The reason why it concentrates quantitative expansion of city without united design by urban plannar is that neglect quality values of city. As a solution of poor environment, there cue out the various efforts, about problem of each building, problem of city space, problem of laws and so forth. The reason why necessity of public space was embossed in that architecture extend the activity of citizen and make up the city space. But, each building pursues the private interest, so it is difficult to secure a public space with a high hand. Thus, architecture law has been revised in 1991 and bring the system of open space to match up the publicity and the private interest. Actually, western country brought it and obtained excellent results. While quantity of open space have increased since 1991, a lot of problems revealed in real usage and quality. By means of problem's solution, this study focus on the diversion of recognition for necessity of various open space. In result, on the occasion of approach and openess, except for several building, most glass a facade and the pedestrian can approach easily. Moreover, office buildings near the subway station connected with their low floor. So, the office buildings give openess to pedestrian and a people can approach easily to the buildings. On the occasion of amenity, most have bank and lobby on the first floor and have facilities on the underground floor. It leave open. But the reason why they have bank and lobby is that the space is dry and boring(without elements of nature and rest space). Hence, to make a space full of vitality, it have to plan various design elements and facilities. First of all, plan of indoor public space have to make up facility for the public interest. This study is basic investigation for necessity of indoor public space and through the survey of office buildings, it analyze the character of plan and find out the method of publicity's realization.

GIS에 의한 대규모 노천광에서의 배수처리 및 사면안정 예측 (Drainage Control and Prediction of Slope Stability by GIS-based Hydrological Modeling at the Large Scale Open Pit Mine)

  • 선우춘;최요순;박형동;정용복
    • 터널과지하공간
    • /
    • 제17권5호
    • /
    • pp.360-371
    • /
    • 2007
  • 이 논문은 GIS 기반의 수리학적 모델링을 통하여 시공측면에서 효과적으로 지표수를 제어하여 배수제어와 사면의 안정성에서의 적용에 관한 것이다. 본 논문에서는 인도네시아 파시르 노천광을 대상으로 연구를 수행한 결과를 제시한다. 신뢰할 수 있는 DEM 자료의 획득을 위하여 상세한 지형측량이 이루어 졌으며, DEM 자료로 부터 빗물의 흐름방향, 누적 흐름양, 집수구역 등의 배수 시스템의 특성을 도출하기 위하여 ArcGIS 9.1 소프트웨어가 제공하는 Hydrology 분석 도구를 사용하였다. 수리학적 모델링과 지형적인 분석의 결과는 현재의 배수처리 설비가 적당하지 않으며 또한 집중되는 지표수의 흐름으로 벤치사면에서 많은 침식이 일어날 수 있음을 보여주고 있다. 마지막으로 배수설비설계의 최적화와 물의 흐름의 제어를 통한 사면의 안전성의 증가와 사면을 감시하기 위한 방법을 제시하였다.

재난관리체계(M(i,j,k)BCP) 제안과 석회석광산의 리스크 평가 (Introduction of the M(i,j,k)BCP and Risk Assessment of Underground Limestone Mine)

  • 이성민;김선명;이연희
    • 터널과지하공간
    • /
    • 제22권6호
    • /
    • pp.383-392
    • /
    • 2012
  • 본 연구에서는 안전하고 친환경적인 광산관리를 위해 스마트 광산재난관리체계인 $M_{(i,j,k)}BCP$(Mining Business Continuity Planning)를 제안하였다. 여기서 'i'는 광산의 종류, 'j'는 광산의 업무공정, 그리고 'k'는 공정별 리스크 이다. 특히, 본 연구는 'i=1=석회석 광산'으로 규정하고 석회석광산의 재난관리체계를 $M_{(i,j,k)}BCP$로 제안하였다. 본 논문에 사용된 광산 리스크들은 문헌자료와 전문가 의견 분석을 통하여 얻었으며, 이러한 리스크들을 석회석 광산의 5대 공정에 맞도록 분류하여 그 수를 약 60개에서 26개로 줄였다. 줄여진 리스크들은 $M_{(i,j,k)}BCP$에 할당되고 평가되었다. 본 연구에서 리스크 평가에 사용한 척도는 1회 이상 발생빈도, 인명피해, 시설물피해, 업무중단시간 등 4가지이다. 리스크 평가 결과에 의하면, 리스크들은 4개의 특화된 군으로 분리될 수 있었다. 또한, 석회석 광산에서는 '채광 중 갱내 낙반 또는 붕락 발생 리스크'의 발생가능성과 위험도가 가장 높은 것으로 나타났다. 이 리스크에 대한 재난관리체계는 '$M_{(1,2,1)}BCP$'이다. 이는 석회석광산 개발시 $M_{(1,2,1)}BCP$가 최우선적으로 수립되어야 함을 의미한다.

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.

CAES 저장 공동 운영단계에서 발생 가능한 리스크 평가 및 화재 시나리오 분석 (Analysis of Fire Scenarios and Evaluation of Risks that might Occur in Operation Stage of CAES Storage Cavern)

  • 윤용균;주은혜;서샘물;최병희
    • 터널과지하공간
    • /
    • 제25권1호
    • /
    • pp.107-114
    • /
    • 2015
  • 본 연구에서는 CAES 저장 공동의 운영단계에서 발생할 가능성이 있는 리스크를 분석 및 평가하고, 가장 높은 리스크 수준을 가지고 있는 것으로 판명된 리스크에 대해서 화재 시나리오를 작성하였다. 운영단계에서의 리스크를 상위 리스크와 하위 리스크로 구분하였다. 상위 리스크는 '기술적 리스크', '시설 리스크', '자연재해 리스크'로 이루어져 있으며, 하위 리스크는 11개의 리스크 요인들로 구성되어 있다. 20인의 관련 분야 전문가에게 설문 조사를 실시하였으며, 설문 내용을 분석하기 위해서 ANP 모델을 적용하였다. 리스크 우선순위를 결정하기 위해서 ANP 분석 결과와 기 결정된 리스크 평가기준을 비교하였으며, 그 결과 '관리공동 내 화재 발생'이 위험도가 가장 높은 리스크로 선정되었다. '관리공동 내 화재 발생' 리스크가 미치는 영향을 평가하기 위하여 시나리오를 작성한 후 분석하였다. 3가지 종류의 시나리오를 고려하였으며, 시나리오를 분석하기 위해서 FDS 화재 해석 프로그램을 사용하였다. 해석 결과 터널 내부에서 외부로 바람이 부는 경우를 가정한 No. 3 시나리오가 연기 확산 속도가 가장 크면서 가장 빠르게 연기가 호흡 한계선 이하까지 하강하는 것으로 나타났다. 따라서 운영요원이 접근터널에서 피난하는 경우 No. 3 시나리오가 가장 불리한 조건으로 판명되었다.