• Title/Summary/Keyword: Under Water Cable

Search Result 35, Processing Time 0.023 seconds

Insulation Reinforcement of the Electrical Power Cable Degradated by the Water Tree Using Silicon (실리콘을 이용한 수트리 열화된 전력 케이블의 절연 보강)

  • Kang, Hyeong-Gon;Park, Jun-Chae;Ko, Seok-Cheol;Lim, Sung-Hun;Lee, C.H.;Hanh, Y.B.;Han, B.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.468-471
    • /
    • 2003
  • Fault of under ground power cable occurs usually from the water tree such as the vented tree, the bow tree and the water-rich halo. The water tree penetrates to the polyethylene cable insulations. Sometimes, the water tree also diffuses to mother cable in the substation. In this paper, instead of replacement of the faulty cable, we tried to cure an electrical power cable degraded by the water trees with silicon injection method. And measured the results with the isothermal relaxation current analysis method. After cable cure, Chonil line was improved from 2.27 to 1.96 in a phase, from 2.148 to 2.020 in b phase, and from badness to 2.192 in c phase. And Keumam line was also improved from 2.419 to 1.920 in a phase, from 2.301 to 2.000 in b phase, and from badness to 1.957 in c phase.

  • PDF

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor. (대용량 탱크에서 물과 유류의 이중 액면 높이 계측용 센서 개발)

  • 김진만;김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.471-474
    • /
    • 2002
  • A fuel tank contains water at the bottom under the fuel. The water comes from humidity by temperature change of inside and outside of tank. So it is necessary to measure both level to check precise amount of oil. But measuring instrument for level of water and fuel is not available yet. Since the fuel is inflammable, the sensor system must not include any electric circuits in the fuel tank. Optical cable sensor can satisfy this non-explosive condition. The displacement of a float changing by water level makes bending curvature of optical cable different. As the float rise up, the optical cable is bent more and the light signal in the cable decreases. The reduction of light signal is detected and it is converted into the change of water level. The output signal from a photo diode shows the proportional relation of water level. The increase of sensor voltage as a unit of ㎷ follows the level position of the float that is located between water and gasoline in the tank.

  • PDF

Dynamic Analysis of Elastic Catenary Cable Subjected to Current (조류 하중을 받는 탄성 현수선 케이블의 동적 해석)

  • 백인열;장승필;윤종윤
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.95-104
    • /
    • 1998
  • The dynamic behavior of the marine cable is essentially nonlinear and dominated by geometric nonlinearity. Furthermore, fluid drag force makes the problem more complex and difficult. Therefore, it has certain limitations to obtain the dynamic behavior of the marine cable by analytical method. The purpose of this paper is to apply the elastic catenary cable element to the problem of under water cable including the hydrodynamic effects of fluids. The static and dynamic formulations for the three-dimensional elastic catenary coble under water effects are derived and the finite element analysis procedures are presented. In the analysis, the hydrodynamic forces are modeled by modified Morison equation. A comparison of the results obtained using present method with previously published results showed the validity of present method. The dynamic behavior of the marine cable subjected to current is investigated using present method and it can be illustrated that the dynamic behavior of the marine cable subjected to current varies with the incident angle of the current and inclined angle of the cable.

  • PDF

Rain-wind induced vibration of inclined stay cables -Part I: Experimental investigation and physical explanation

  • Cosentino, Nicola;Flamand, Olivier;Ceccoli, Claudio
    • Wind and Structures
    • /
    • v.6 no.6
    • /
    • pp.471-484
    • /
    • 2003
  • The rain-wind induced vibration of stays is a phenomenon discovered recently and not well explained yet. As it is influenced by a wide range of physical parameters (cable size and shape, wind speed, direction and turbulence, rain intensity, material repellency and roughness, cable weight, damping and pre-strain), this peculiar phenomenon is difficult to reproduce in laboratory controlled conditions. A successful wind tunnel experimental campaign, in which some basic physical quantities were measured, allowed an extensive analysis as to identify the parameters of the rain-wind induced excitation. The unsteady pressure field and water thickness around a cable model were measured under rainy-excited conditions. The knowledge of those parameters provided helpful information about the air-flow around the cable and allowed to clarify the physical phenomenon which produces the excitation.

A Study on Design and Performance Test for Underwater Towing Sonar Cable (수중 예인 소나용 케이블 설계 및 성능에 대한 연구)

  • Jae-Hyun, Na;Eui-Chang, Hong;Seung-Cheon, Kim;Dong-Gil, Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1095-1104
    • /
    • 2022
  • The towing cable plays a role in dropping and salvaging the Towed Array Sonar System (TASS) into the water and transmitting the signal (information) detected by the sonar in the water to the probe or surface ship. The towing cable consists of a heavy cable and a lightweight cable in detail. The towing cable for sonar is characterized by high reliability and durability as the underwater environment deteriorates as the operating depth increases. Due to these restrictions, cases designed and manufactured in Korea are extremely rare. The core technology for towing cable design secured through this study is expected to be used in various ways in the defense industry and the private sector.

A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System (간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구)

  • Park, M.H;Che, G.S.;Seo, J.Y.;Kim, J.G.;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

Nonlinear Analysis of Underwater Towed Cable Using Robust Nodal Position Finite Element Method (강건 절점위치 유한요소법을 이용한 수중 예인 케이블의 비선형 거동해석)

  • Lee, Euntaek;Go, Gwangsoo;Ahn, Hyung Taek;Kim, Seongil;Chun, Seung Yong;Kim, Jung Suk;Lee, Byeong Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.5
    • /
    • pp.388-399
    • /
    • 2016
  • A motion analysis of an underwater towed cable is a complex task due to its nonlinear nature of the problem. The major source of the nonlinearity of the underwater cable analysis is that the motion of the cable involves large rigid-body motion. This large rigid-body motion makes difficult to use standard displacement-based finite element method. In this paper, the authors apply recently developed nodal position-based finite element method which can deal with the geometric nonlinearity due to the large rigid-body motion. In order to enhance the stability of the large-scale nonlinear cable motion simulation, an efficient time-integration scheme is proposed, namely predictor/multi-corrector Newmark scheme. Three different predictors are introduced, and the best predictor in terms of stability and robustness for impulsive cable motion analysis is proposed. As a result, the nonlinear motion of underwater cable is predicted in a very efficient manner compared to the classical finite element of finite difference methods. The efficacy of the method is demonstrated with several test cases, involving static and dynamic motion of a single cable element, and also under water towed cable composed of multiple cable elements.

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor

  • Kim, Hiesik;Lee, Byoungsuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.1-95
    • /
    • 2002
  • <1. New level meter inside the fuel tank> Ultrasound level sensors are widely applied as level meters of liquid tank. Measurement instrument of level between water and fuel is developed. Since the fuel is inflammable, the sensor system doesn't allow to include any electric circuit inside the fuel tank. The optical cable sensor can satisfy this explosive condition. The measurement method with ultrasonic sensor is attached on the tank wall or tank manhole lid. The pressure sensor can't be applied inside the gasoline fuel tank. An ultra-sonic sensor doesn't detect a enough signal reflected from water level deep under gasoline fuel. The pressure sensor is difficult to measure the height o...

  • PDF

Numerical model of a tensioner system and riser guide

  • Huang, Han;Zhang, Jun;Zhu, Liyun
    • Ocean Systems Engineering
    • /
    • v.3 no.4
    • /
    • pp.257-273
    • /
    • 2013
  • Top tensioned riser (TTR) is often used in a floating oil/gas production system deployed in deep water for oil/gas transport. This study focuses on the extension of the existing numerical code, known as CABLE3D, to allow for static and dynamic simulation of a TTR connected to a floating structure through a tensioner system or buoyancy can, and restrained by riser guides at different elevations. A tensioner system usually consists of three to six cylindrical tensioners. Although the stiffness of individual tensioner is assumed to be linear, the resultant stiffness of a tensioner system may be nonlinear. The vertical friction between a TTR and the hull at its riser guide is neglected assuming rollers are installed there. Near the water surface, a TTR is forced to move horizontally due to the motion of the upper deck of a floating structure as well as related riser guides. The extended CABLE3D is then integrated into a numerical code, known as COUPLE, for the simulation of the dynamic interaction among the hull of a floating structure, such as spar or TLP, its mooring system and riser system under the impact of wind, current and waves. To demonstrate the application of the extended CABLE3D and its integration with COUPLE, the numerical simulation is made for a truss spar under the impact of Hurricane "Ike". The mooring system of the spar consists of nine mooring lines and the riser system consists of six TTRs and two steel catenary risers (SCRs).

Analysis of signal cable noise currents in nuclear reactors under high neutron flux irradiation

  • Xiong Wu;Li Cai;Xiangju Zhang;Tingyu Wu;Jieqiong Jiang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4628-4636
    • /
    • 2023
  • Cables are indispensable in nuclear power plants for transmitting data measured by various types of detectors, such as self-powered neutron detectors (SPNDs). These cables will generate disturbing signals that must be accurately distinguished and eliminated. Given that the cable current is not very significant, previous research has focused on SPND, with little attention paid to cable evaluation and validation. This paper specifically focuses on the quantitative analysis of cables and proposes a theoretical model to predict cable noise. In this model, the reaction characteristics between irradiated neutrons and cables were discussed thoroughly. Based on the Monte Carlo method, a comprehensive simulation approach of neutron sensitivity was introduced and long-term irradiation experiments in a heavy water reactor (HWR) were designed to verify this model. The theoretical results of this method agree quite well with the experimental measurements, proving that the model is reliable and exhibits excellent accuracy. The experimental data also show that the cable current accounts for approximately 0.2% of the total current at the initial moment, but as the detector gradually depletes, it will contribute more than 2%, making it a non-negligible proportion of the total signal current.