• Title/Summary/Keyword: Unbalanced source

Search Result 141, Processing Time 0.027 seconds

Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems

  • Pirouz, Hassan Mohammadi;Bina, Mohammad Tavakoli
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.572-578
    • /
    • 2010
  • This paper discusses a transformerless shunt static compensator (STATCOM) based on a modular multilevel converter (MMC). It introduces a new time-discrete appropriate current control algorithm and a phase-shifted carrier modulation strategy for fast compensation of the reactive power and harmonics, and also for the balancing of the three-phase source side currents. Analytical formulas are derived to demonstrate the accurate mechanism of the stored energy balancing inside the MMC. Various simulated waveforms verify that the MMC based STATCOM is capable of reactive power compensation, harmonic cancellation, and simultaneous load balancing, while controlling and balancing all of the DC mean voltages even during the transient states.

Investigation of Underwater Sound Detection Characteristics of Fiber Optic Hydrophone Array by using an Unbalanced Interferometer (불평형 간섭계를 이용한 광섬유 청음기 배열의 수중음향 감지특성 연구)

  • 이종길;남성현;윤형규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.617-621
    • /
    • 1998
  • Optical sensing techniques have been associated with high sensitivity and precise measurements and attracted considerable attention in recent years. In this paper, two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array for the underwater applications was fabricated and their acoustic characteristics were investigated by using the acoustic water tank. A fiber length of the order of 100m is wounded at the hollow cylinder type aluminum mandrel. An unbalanced interferometer (discrete Mach-Zehnder type) was used. Sound detection performance is tested in the underwater tank with 2kHz continuous sound source. Finally, it is shown that two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array can detect 2kHz sound stably.

  • PDF

A Study on the Lighting Environment Improvement of the VDT Workspaces in Computer Room (컴퓨터실에 있어서 VDT작업공간의 조명환경 개선에 관한 연구)

  • Jung, Jin-Hyun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.3
    • /
    • pp.31-39
    • /
    • 1997
  • The purpose of this study was to improve the lighting environment of the VDT workspaces in computer laboratory. This study was carried out through the field measurements on the computer laboratory and a survey using the questionnaire about the VDT workspaces. The major findings of the study were as follows: (1) It was unbalanced among the illumination, luminance, and color distributions in the the VDT workspaces. (2) The difference of brightness between the CRT screen and its surroundings have presented on the whole unbalanced. (3) It was proved that the artificial light source of the ceiling lighting should use the parabolic louver luminaire limiting the radiant luminance.

  • PDF

Dynamic Analysis of an Optical Disk Drive with Dynamic Vibration Absorber (동흡진기를 채용한 광 디스크 드라이브의 동적 해석)

  • 김남웅;김국원;황효균;김동규;이진우;김외열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.867-870
    • /
    • 2002
  • In high-speed optical disk drive, the excitation caused by rotation of a mass-unbalanced disk is a major source of vibration. The vibration can be a disturbance to the servo system, which is sufficient to cause severe failures in the reading and writing process. The vibration also causes users to feel unpleasantness. The vibration reduction is therefore essential for the reliable operation of optical disk drive. One of the approaches to reduce the vibration is a dynamic vibration absorber (DVA). In this paper, we analyze the dynamic behavior of $DVD\pmRW$ combo drive system with DVA through 12_dof rigid multi-body dynamic model. The effective location and the optimal frequency ratio are obtained from the analysis.

  • PDF

Velocity Calibration of Sinusoidal Mode for Mossbauer Spectrometer and Mossbauer Study on $Fe_3O_4$ (사인파속도형 Mossbauer 분광계의 속도눈금 매기기와 Magnetite의 Mossbauer 분광법에 의한 연구)

  • 이충섭;이찬영
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.232-236
    • /
    • 1997
  • We have gone into details about the velocity calibration of sinusoidal mode for Mossbauer spectrometer. Since sinusoidal Mossbauer spectrometer has a ${\gamma}$-ray source that oscillates at the end of loudspeaker with the natural frequency. Doppler velocity is accurate and stable. From the analyzing Mossbauer spectra of $Fe_3O_4$ and U $Fe_3O_4$ (unbalanced $Fe_3O_4$), we have shown the power of correct velocity for sinusoidal mode.

  • PDF

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

Neutral line current elimination method for Active power filter of three phase four-wire power system (중성선 전류 제거를 위한 3상 4선식 능동 전력 필터)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1489-1491
    • /
    • 2005
  • This paper proposes a design method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition and unbalanced source voltage condition in three-phase four-wire systems. For reduction of current harmonics and neutral current, the control structure including repetitive controller is proposed and controller gain is designed. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

The Average Power Algorithm of Active Power Filters for Asymmetrical Three-Phase Three-Wire Power System (비대칭 3상 3선 전원 시스템을 위한 능동전력필터의 평균전력 알고리즘)

  • 정영국;김우용;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.514-524
    • /
    • 2001
  • Conventional average power theory has been used to design and control active power filters But compensating reference currents of active power filters calculated by conventional average power theory are definitively influenced by three phase source voltage conditions such as unbalance or distortion. This paper presents a new average power algorithm for active power filters which can detect symmetrically equally active or fundamental reactive currents in each phase based on decomposition of fundamental reactive component and harmonics under unbalanced power conditions. The effectiveness of the proposed algorithm is demonstrated by MATLAB/SIMULINK simulation and experimental results for a three wire distribution system with 15% unbalanced source voltages.

  • PDF

Two Switches Balanced Buck Converter for Common-Mode Noise Reduction

  • Kanjanasopa, Warong;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.493-498
    • /
    • 2004
  • The EMI noise source in a switching mode power supply is dominated by a common mode noise. If we can understand the common mode noise occurring mechanism, it is resulted to find out the method to suppress the EMI noise source in the switching mode power supply. The common mode noise is occurring mostly due to circuit is unbalanced which is caused by the capacitive coupling to frame ground, which passes through a heatsink of the switching devices. This research paper presents a new effective balancing method of buck converter circuit by mean of grounding the parasitic and compensation capacitors in correct proportion which is called that the common mode impedance balance (CMIB). The CMIB can be achieved by source, transmission line and termination balanced, such balancing, the common mode current will be cancelled out in the frame ground. The greatly reduced common mode noise can be confirmed by the experimental results.

  • PDF

DSP-Based Direct Source Current Control for Three-Phase Four-Wire Power Coditioner

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Yoo, D.W.;Song, E.H.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.871-875
    • /
    • 1998
  • A DSP-based source current control for power conditioner is presented to compensate current harmonics and asymmetries of three-phase four-wire emergency generators caused by nonlinear and/or unbalanced loads. There-phase voltage type converter with split-dc-capacitor is adopted as the power circuit and a new direct source current control method is suggested, which simplifies the controller. The proposed control method shapes the generator current sinusoidally inphase with the voltage and allows the generator to supply maximum power even to single phase loads. An IGBT base lookVA prototype with the controller realized with a DSP (TMS320C32) is built and tested to verify the performance of the power conditioner.

  • PDF