• Title/Summary/Keyword: Unbalanced source

Search Result 141, Processing Time 0.025 seconds

A 3 Dimensional Characteristic Analysis of SLIM by the 2-D Finite Element Method (2차원 유한요소법에 의한 SLIM의 3차원적 특성 해석)

  • Cho, Yun-Hyun;Kim, Yong-Joo;Shin, Pan-Seok;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.37-42
    • /
    • 1990
  • In order to obtain optimal design criteria and operating parameters, a Single-sided Linear Induction Motor (SLIM) is analysed by using a 2-D finite element method with magnetic and current vector potential. In the analysing procedures, the governing equation is derived from Maxwell's equation combined with the magnetic vector potential. As a forcing term, 3-phase voltage source is employed using the Kirchhoff's voltage law in order to look into effects of the unbalanced 3-phase currents and air gap flux density. Also, 2ndary eddy current distribution, longitudinal end and transverse edge effects are in turns visualized by flux lines in 3 different analysing planes as functions of frequency and input power.

  • PDF

The Unbalanced Source Voltages Compensation Using by Unified Active Power Filter System (직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상)

  • Kang, Min-Hyung;Kim, Young-Jo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.149-151
    • /
    • 2006
  • 본 논문에서는 고조파 보상과 역율 보상을 실시하고, 전원 전압 불평형시 보상을 실시하는 직 병렬 능등전력필터에 관하여 연구하였다. 직렬형 능동전력필터에서는 고조파에 대한 보상 전압만을 발생하여 제어하고, 병렬형 능동전력필터에서는 역율에 대한 보상하는 전류만을 발생하여 제어한다. 또한, 불평형 전원 전압에 대한 보상은 직렬형 능동전력필터에서 실시하며, 고조파 보상과 역율 보상은 성능함수에 의해 계산되어지며, 불평형 전원 전압 보상은 대칭 좌표법을 이용하여 계산되어진다. 제시된 실험 결과들은 알고리즘의 타당성과 유효성을 검증한다.

  • PDF

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

Optimal Switching Position of Two-Phase Brushless DC Motor with the Consideration of Vibration (진동을 고려한 2상 BLDC 모터의 최적 스위칭 위치)

  • 정중기;최연선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.465-470
    • /
    • 2001
  • Two-phase BLDC(brushless DC) motor has larger torque ripple than three-phase BLDC motor because of its unique skeleton-type structure. An electronic switching mechanism to change the current-direction of the BLDC motor can be a source of vibration as well as unbalanced rotor weight. A proper switching timing which makes less vibrations was considered by changing the position of sensing element around the center of rotation. Also, the current of the motor was measured for the calculation of the motor efficiency. From the vibration test results and with the consideration of the motor efficiency, an optimal switching position of the Hall sensor was found.

  • PDF

3-Phase Hybrid Series Active Power Filter with Dynamic Voltage Restorer (DVR 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • Han Seok-Woo;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.598-602
    • /
    • 2002
  • This paper presents the 3-phase hybrid series active power filter with dynamic voltage restorer(DVR) which serve as an energy buffer and current harmonics blocking resistor connected to sensitive loads, such as, to compensate voltage dips and current harmonics in power distribution system. The DVR is to inject a dynamically controlled voltage generated by a forced commutated converter in series to the bus voltage by means of a booster transformer. The momentary amplitudes of the three injected phase voltages are controlled such as to eliminate any detrimental effects of a bus fault to the load voltage. The proposed system is able to simultaneously compensate current harmonics, voltage fluctuating and voltage unbalance in power distribution systems. The reference phase angle detected by synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The effectiveness of proposed system is verified by the computer simulation.

  • PDF

Design of Voltage Balancing Circuit applied to Multiple Cells (다중셀에 적용된 전압안정화회로 설계)

  • Hwang H. S.;Nam J. H.;Jang D. K.;Choi J. H.;Sin I. S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.193-196
    • /
    • 2003
  • For a power source of usual electronic devices such as PDA, smart phone, UPS and electric vehicle, the battery made of serially connected multiple cells is generally used. In this case, if there are some unbalanced among cell voltages, the total lifetime and the total capacity of the battery are limited to a lower value. To maintain a balanced condition in cells, an effective method of regulating the cell voltage in indispensable. In this paper introduced a method for battery balancing system using dissipation in the resistance.

  • PDF

A NEW INSTANTANEOUS VOLTAGE COMPENSATOR WITH FUNCTION OF ACTIVE POWER FILTERING

  • Lee, Seung-Yo;Lee, Jeong-Min;Lee, Sang-Yong;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.780-784
    • /
    • 1998
  • A novel active input unbalance voltage compensator with harmonic current compensating capability is proposed and the operating principle of the proposed system is presented in the 3-phase power system. The proposed system performs both the voltage regulation of the load and the compensation of the harmonic currents generated due to nonlinear load such as diode rectifier. The system to compensate unbalanced voltage and hramonic currents is composed of a 3-phase voltage source inverter, LC filter, series transformer and passive devices at the load side of the line. The compensating voltage to regulate the load voltage and to remove the harmonic current components is transmitted to the line by the series transformer. The validity of the line by the series transformer. The validity of the proposed system is proved by the results of computer simulation.

  • PDF

Vibration Reduction of an Optical Disk Drive with a Dynamic Vibration Absorber (동흡진기를 사용한 광 디스크 드라이브의 진동저감)

  • Kim, Nam-Woong;Sin, Hyo-Chol;Kim, Kug-Weon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.529-536
    • /
    • 2006
  • In high-speed optical disk drive, the excitation caused by rotation of a mass-unbalanced disk is a major source of vibration. The vibration can be a disturbance to the servo system, which is sufficient to cause severe failures in the reading and writing process. The vibration also causes users to feel unpleasantness. The vibration reduction is therefore essential for the reliable operation of optical disk drive. One of the approaches to reduce the vibration is a dynamic vibration absorber(DVA). In this paper, we analyze the dynamic behavior of $DVD{\pm}RW$ combo drive system with DVA through 12-dof rigid multi-body dynamic model. The effective location and the optimal frequency ratio for the DVA are obtained from the analysis. The DVA are fabricated based on the analysis and its usefulness is confirmed.

전력사업에서의 분리막 이용현황 및 전망

  • 박광규
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.111-130
    • /
    • 1997
  • The lack of water resources is becoming worse due to water pollution with accelerated industrialzation and regional unbalanced distribution of water resources. In recent, the production water quality is decreasing because of the increased organic matters and soluble solids in the water sources for power plants. The purpose of this paper discribes the ststus and prospect of membrane application in electric power industry. So this study lies in developing a process which can produce high purity water by appluing RO(Reserve Osmosis) ahead of the IX(Ion Exchange) tower and evaluating the product water quality and the cost effectiveness. The capital and operating cost for the treatment of brackish water, sea water by RO were presented as a reference for the review on securing water source for the new plant site.

  • PDF

New Control Seheme for AC-DC-AC Converters without DC Link Electrolytic Capacitor (직류링크 전해커패시터 없는 AC-DC-AC 컨버터 재어에 관한 연구)

  • 김준석;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.397-408
    • /
    • 1994
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with a unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $\mu$F ceramic capacitor in the DC link. By controlling the active kpower balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitors regardless of the load variation even in the unbalanced source condition.