순시전압강하 보상기의 새로운 제어 기법 (A New Control Algorithm for Instantaneous Voltage Sag Corrector)

  • 이상훈;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정 (Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device)

  • 이문형;정재희
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

웨이블릿 변환을 이용한 고장과 Variation의 유형 구분 알고리즘 개발 (Development of the Algorithm for Discriminating Faults from Variation using Wavelet Transform)

  • 서훈철;이순정;김철환
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1460-1466
    • /
    • 2011
  • This paper proposes the algorithm for discriminating faults from the variation due to the operation of non-linear components to prevent the mal-operation of protection relay in the distribution system. An IEEE 13 node test feeder is modeled to analyze the characteristics of the fault and each variation using EMTP-RV. Simulations with various operating conditions of transformers, non-linear loads, and unbalanced loads are performed using the test feeder model. Based on simulation results, the wavelet transform is adopted to analyze the current waveforms from the faults and variations to find out the differences between them and the algorithm for discriminating faults from the variation is proposed. The proposed algorithm is verified by using the current waveforms simulated in the KEPCO's distiribution system and IEEE 13 node test feeder.

낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준 (Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation)

  • 우정욱;문재덕
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

계통전압 불평형시 Fault Ride Through와 전압보상 기능을 갖는 계통연계 인버터의 제어기법 (Control Method for Utility Interactive Inverter with Fault Ride Through and Voltage Compensation under Unbalanced Grid Voltages)

  • 김형진;정아진;김주하;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2012
  • 최근 분산발전시스템에서 계통의 보호를 위해 계통전압 이상이 발생하더라도 일정시간 계통과의 연결을 강제하는 FRT기능이 요구되고 있으며 계통전압 불평형 시에도 계통과의 연결을 유지하도록 요구하고 있다. 이때 독립부하가 존재하는 경우 계통의 이상전압이 독립부하에 그대로 걸리게 되어 독립부하의 전압품질이 저하되는 문제가 있다. 본 논문에서는 계통전압 불평형시 FRT를 수행함과 동시에 독립부하에도 일정한 품질의 전압을 공급할 수 있는 전압보상 기법을 제안한다.

  • PDF

복합고장을 가지는 농형유도전동기의 모델링과 고장진단 (Fault diagnosis and modeling in squirrel-cage induction motor under a combination of unbalanced voltage and broken rotor bar)

  • 박진수;김연태;배현;김성신
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2006년도 추계학술대회 학술발표 논문집 제16권 제2호
    • /
    • pp.163-166
    • /
    • 2006
  • 유도전동기는 산업시스템에 있어서 필수적인 요소이기 때문에 유지 관리, 모니터링시스템, 고장 진단 등의 다양한 분야에서 많은 연구가 행해지고 있다. 유도전동기의 운전 중 하나의 고장이 발생한 경우 이것은 전동기의 다른 부분에 영향을 미치거나 또 다른 고장을 유발시키는 원인이 된다. 따라서 개별적인 고장뿐만 아니라 결합된 형태의 고장을 검출하고 진단하는 것은 유용한 방법이다. 본 논문에서는 전압불평형 고장과 회전자바 고장이 발생한 경우, 그리고 두 고장이 동시에 복합적으로 발생한 경우를 모델링하고 이에 대해 고장 진단을 하였다. 제안된 고장 검출 및 진단 알고리즘은 농형운도전동기의 고정자 전류를 이용하였으며 매트랩 시뮬링크를 사용하여 시뮬레이션 하였다.

  • PDF

15 kVA급 박막형 초전도 전류제한기의 한류특성 (Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films)

  • 최효상;현옥배;김혜림;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

15 kVA급 저항형 초전도 한류기의 전류제한특성 (Characteristics of 15 kVA superconducting fault current limiter)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

2차 권선과 초전도 사이의 중성선 유무에 따른 변압기형 초전도 한류기의 동작특성 (Operational Characteristics of Transformer-Type SFCL with or without Neutral Line between the Secondary windings and Superconducting units)

  • 조용선;최효상;고성필
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1268-1273
    • /
    • 2011
  • The study on power capacity increase of superconducting fault current limiter (SFCL) is one of the most important researches to apply a SFCL in the power system. To achieve this, we thought that the unbalanced quenching problem generated in series connection of superconducting units should be solved. In this paper, we investigated the quenching characteristics of superconducting units in the transformer-type SFCL with or without the neutral line between secondary windings and superconducting units. In case of transformer-type SFCL without neutral line, the connection structure of superconducting units is identical to that of the resistive-type SFCL connected in series. Therefore, the unbalanced quenching was occurred by difference of critical current between superconducting units. However, in case of transformer-type SFCL with neutral line, the superconducting units with different critical current were simultaneously quenched. It was because the currents induced by secondary winding were separately flowed through the superconducting units. By these results, we confirmed that the resistances and consumption powers of the superconducting units were equally generated.