• 제목/요약/키워드: Ultraviolet Light Source

검색결과 67건 처리시간 0.025초

질소를 도핑한 TiO2를 이용한 부식산 분해 (Degradation of Humic Acid Using N-Doped TiO2)

  • 소지양;이동석
    • 산업기술연구
    • /
    • 제31권B호
    • /
    • pp.119-125
    • /
    • 2011
  • N-doped Titanium oxides were prepared by using urea as a source of nitrogen. The photoactivities of the doped $TiO_2$ were evaluated on the basis of degradation of humic acid in aqueous solutions with different light sources, ultraviolet lamp, fluorescent lamp and solar light. XRD analysis was conducted to identify the crystal structure of the synthesized photocatalysts. N-doped $TiO_2$ and $pure-TiO_2$ was anatase type. SEM results showed that spherical particles were formed, which are the characteristics of the anatase form. N doped $TiO_2$ showed higher $UV_{254}$ decrease ratio and DOC removal ratio compared to $pure-TiO_2$. The humic acid degradation reaction using the UV-A lamp and UV-C lamp was assigned to pseudo-first order reaction. For solar light, only $pure-TiO_2$ and $N-TiO_2$ exhibited the pseudo-first order reaction.

  • PDF

중첩다단 메쉬회로를 적용한 펄스형 Nd:YAG 레이저의 2차 고조파 변환효율에 관한 특성연구 (A characteristics study on the Second-harmonic generation conversion efficiency of Pulsed Nd:YAG Laser adopted Superposition multiple Mesh Networks)

  • 김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권4호
    • /
    • pp.565-572
    • /
    • 2001
  • 최근 고체 레이저 출력측에 비선형 광학재료를 설치하여 적외선에서 자외선에 이르기까지 넓은 대역의 파장을 가진 레이저광이 요구된다. 비선형 광학소자는 고조파발생기와 파라메터 발생기와 같은 레이저원을 이용한 주파수 전 영역까지 확장 할 수가 있다. 주파수 변환은 고전력 레이저를 이용한 확장기술에 많이 이용하고있다. 새로운 각 주파수 대역에서 광학 매개체의 비선형 광학의 응답 등을 이용할 수가 있다. 이러한 과정들은 자외선영역에서 적외선까지 고전력 방사발생을 이용할 수가 있다. 광학 파라메터발생기와 증폭기는 저주파수에서 2가지 파장 등을 발생한다. 싱글 주파수원으로부터 발생하여 몇몇의 경우에는 가시광선 영역에서 거의 자외선 영역까지 이용할 수가 있다. 결과적으로 녹색광을 얻기 위해서, 펄스형Nd:YAG 레이저는 다단펄스 포밍회로를 이용하였고 비선형광학(KTP)소자를 채택하여 적용하였다. 따라서 본 연구에서는 펄스 중첩법을 이용하여 기본파로서 직접 설계 제작 후 SHG 장치를 장착하여 녹색광을 얻고 각 중첩 메쉬에 같은 에너지를 인가했을 때의 레이저 출력과 녹색광 출력간의 상관관계와 메쉬 수에 따른 변환효율을 조사하였다.

  • PDF

수산 시설용 재료의 내후성에 관한 연구 2. 부력재용 플라스틱 재료의 내후성 (Resistance to Weathering with Materials for Fisheries Facilities 2. Photodegradation of Plastic Materials for Floatation Unit)

  • 김태호
    • 수산해양기술연구
    • /
    • 제37권2호
    • /
    • pp.140-146
    • /
    • 2001
  • 수산 시설물의 내구성을 평가하기 위한 기초 단계로 부력재 또는 프레임용 재질로 많이 사용되고 있는 국산 고밀도 PE 및 고강도 PVC와 노루웨이 고밀도 PE에 대하여 인공 광원을 조사한 후 시간의 경과에 따른 시료의 물성과 그 표면 및 파면의 형태적 변화를 비교$\cdot$분석하였다. 실험에서 얻어진 결과를 요약하면 다음과 같다. 1) 자외선 조사 시간이 경과됨에 따라 세 시료 모두 인장 응력과 탄성률은 미처리된 초기의 그것보다 크게 감소하였으나, 파단 신장률의 경우 처음에는 증가하다가 다시 감소하는 불규칙적인 경향을 나타내었다. 2) 잔여 응력 RS(kg/mm 상(2))와 자외선 폭로 기간 Y(Year)와의 상관 관계는 다음과 같이 나타났다. KHDPE : RS=2.6769-0.0003Y(r 상(2)=0.63) Hi-PVC : RS=5.3470-0.0003Y(r 상(2)=0.91) NHDPE : RS=2.4929-0.0004Y(r 상(2)=0.97) 3) 전자 현미경 촬영 결과, 자외선의 영향으로 시료의 표면에 물방울 형상이 나타났으며, 자외선 조사 시간이 경과됨에 따라 분자 구조의 분해로 인하여 작은 구멍이 확인되었다.

  • PDF

단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구 (A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene)

  • 김창환;신진용
    • 공업화학
    • /
    • 제24권2호
    • /
    • pp.138-143
    • /
    • 2013
  • 화학적 열화를 빠르게 유도할 수 있는 단파장의 자외선(254 nm)을 고밀도 폴리에틸렌의 표면에 조사하여, 생성된 carbonyl band의 변화로부터 기계적 물성 변화를 예측할 수 있는 지에 대한 가능성을 연구하였다. 오랜 시간이 요구되는 자연 태양광에 의한 옥외폭로시험이나, 제논-아크 광원에 의한 광 열화 대신에 광양자 에너지가 높은 UVC 램프를 사용함으로써, 유도되는 광열화의 화학적 특성이 동일한 기계적 물성 변화를 유발하는지를 확인하는 것에 본 연구의 의미가 있다. 인장시험과 크리프-파괴시험으로 진행된 고밀도 폴리에틸렌의 기계적 강도는 CI 변화에 유사한 양상을 보였으며, 특히 항복강도와 신장률은 자외선 노출시간과 밀접한 관계가 있음을 보여주었다. 따라서 빠른 표면 열화를 유발하는 UVC 램프를 활용한 카르보닐 지수와 기계적 물성 변화의 관계를 통하여 장시간이 요구되는 옥외에서의 기계적 물성변화를 보다 빠르게 파악할 수 있는 방법을 제시하였다.

Measurement of the Thermal Conductivity of a Polycrystalline Diamond Thin Film via Light Source Thermal Analysis

  • Kim, Hojun;Kim, Daeyoon;Lee, Nagyeong;Lee, Yurim;Kim, Kwangbae;Song, Ohsung
    • 한국재료학회지
    • /
    • 제31권12호
    • /
    • pp.665-671
    • /
    • 2021
  • A 1.8 ㎛ thick polycrystalline diamond (PCD) thin film layer is prepared on a Si(100) substrate using hot-filament chemical vapor deposition. Thereafter, its thermal conductivity is measured using the conventional laser flash analysis (LFA) method, a LaserPIT-M2 instrument, and the newly proposed light source thermal analysis (LSTA) method. The LSTA method measures the thermal conductivity of the prepared PCD thin film layer using an ultraviolet (UV) lamp with a wavelength of 395 nm as the heat source and a thermocouple installed at a specific distance. In addition, the microstructure and quality of the prepared PCD thin films are evaluated using an optical microscope, a field emission scanning electron microscope, and a micro-Raman spectroscope. The LFA, LaserPIT-M2, and LSTA determine the thermal conductivities of the PCD thin films, which are 1.7, 1430, and 213.43 W/(m·K), respectively, indicating that the LFA method and LaserPIT-M2 are prone to errors. Considering the grain size of PCD, we conclude that the LSTA method is the most reliable one for determining the thermal conductivity of the fabricated PCD thin film layers. Therefore, the proposed LSTA method presents significant potential for the accurate and reliable measurement of the thermal conductivity of PCD thin films.

Kinetic Study of the Visible Light-Induced Sonophotocatalytic Degradation of MB Solution in the Presence of Fe/TiO2-MWCNT Catalyst

  • Zhang, Kan;Oh, Won-Chun
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1589-1595
    • /
    • 2010
  • In order to effective degradation of organic dye both under visible light or ultrasonic irradiation, the MWCNTs (multiwalled carbon nanotube) deposited with Fe and $TiO_2$ were prepared by a modified sol-gel method. The Fe/$TiO_2$-MWCNT catalyst was characterized by surface area of BET, scanning electron microscope (SEM), Transmission Electron Microscope (TEM), X-ray diffraction (XRD), and energy dispersive X-ray (EDX) and ultraviolet-visible (UV-vis) spectroscopy. The low intensity visible light and low power ultrasound was as an irradiation source and the methylene blue (MB) was choose as the model organic dye. Then degradation experiments were carried out in present of undoped $TiO_2$, Fe/$TiO_2$ and Fe/$TiO_2$-MWCNT catalysts. Through the degradation of MB solution, the results showed the feasible and potential use of Fe/$TiO_2$-MWCNT catalyst under visible light and ultrasonic irradiation due to the enhanced formation of reactive radicals as well as the possible visible light and the increase of ultrasound-induced active surface area of the catalyst. After addition of $H_2O_2$, the MB degradation rates have been accelerated, especially with Fe/$TiO_2$-MWCNT catalyst, in case of that the photo-Fenton reaction occurred. The sonophotocatalysis was always faster than the respective individual processes due to the more formation of reactive radicals as well as the increase of the active surface area of Fe/$TiO_2$-MWCNT catalyst.

365 nm 및 385 nm SMD LED와 TIR 바형 렌즈를 이용하는 고밀도 고균일성 특성의 경화용 광원모듈 제작 (Fabrication of High Density and High Uniformity Irradiation Light Source for Exposure Curing System Using 365 nm and 385 nm Wavelength SMD LED and High Transmittance Silicone Resin TIR Bar Type Lens )

  • 정필홍;김범진;김영진;전동규;김효민;김재현;김형민;이규성;;박응렬;유순재;안민준;황도원
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.394-399
    • /
    • 2024
  • An irradiator is developed using two UVA wavelength ranges of SMD LEDs as a curing light source. This module has dimensions of 545×111×300 mm3 and is equipped with a TIR bar-shaped lens made of PDMS silicone resin. The developed irradiator offers high uniformity, with 89% in the centerline of the horizontal axis direction, for two different wavelength ranges of 365 nm and 385 nm. The radiation intensity from the light source module shows highly directional characteristics, and the irradiator provides a maximum irradiance of 1,634 mW/cm2 at a working distance of 50 mm. During the initial 5 minutes of operation, the irradiance experiences a rapid decrease. However, this issue is addressed by optimizing the LED's current reduction characteristics and managing the Transistor's temperature rise in the constant current circuit. After continuous operation for approximately 60 minutes. The highest temperature, near the central part of the irradiating surface, reaches 69.7℃, while the lowest temperature, near the edges, is 41.1℃.

UV광 측정용 아조벤젠 코팅된 FBG의 열적 효과 제거 및 파장 의존성에 대한 연구 (The Study of Thermal Effect Suppression and Wavelength Dependence of Azobenzene-coated FBG for UV Sensing Application)

  • 최동석;김현경;안태정
    • 한국광학회지
    • /
    • 제22권2호
    • /
    • pp.67-71
    • /
    • 2011
  • 본 논문에서는 ultraviolet (UV) 광의 세기를 원격으로 측정하기 위한 아조벤젠 (azobenzene) 코팅된 fiber Bragg grating (FBG)를 구현하였다. 아조벤젠 폴리머는 UV 광에 의해서 탄성이 변화하여 FBG의 코어 격자의 주기 변화를 유도하여 중심파장을 이동시킨다. 중심파장의 이동은 UV 광과 UV 이외의 파장대역의 빛에 의해서 복합적으로 발생하는데 중심파장의 이동량은 약 0.18 nm 이다. 측정의 정확성을 향상시키기 위해서 광원의 복사열에 의한 중심파장의 이동을 열차단 필터(thermal filter)를 사용하여 제거한 결과 중심파장의 이동량은 약 0.06 nm로 다소 감소하였지만 분석 결과 열에 의한 이동량이 충분히 제거된 것을 확인하였다. 또한 서로 다른 방법인 열경화법과 UV 경화법으로 각각 제작된 아조벤젠 폴리머를 이용하여 아조벤젠 코팅 FBG를 제작하였고, 각 제조법에 따른 UV센서로서의 적합성을 확인하였다. 몇 개의 밴드패스 필터(band pass filter)를 사용하여 파장에 대한 민감도를 측정한 결과, 단위 UV 세기당 중심파장의 이동량은 370nm 파장 밴드에서 가장 큰 값인 0.029로, 단파장 영역에서 반응성이 우수하다는 사실을 확인 하였다. 아조벤젠 폴리머의 흡수 스펙트럼과 아조벤젠 코팅 FBG의 파장 의존도가 서로 잘 일치하는 것을 확인하였다.

방전여기 XeCl 엑시머레이저의 제작 및 동작특성 (Development and Operation Characteristics of XeCl Excimer Laser)

  • 진윤식;이홍식;김희제;노영수;김윤택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.268-271
    • /
    • 1993
  • Discharge pumped high power excimer laser is a very useful light source of ultraviolet region. In this paper. the design and operation characteristics of UV pre-ionized discharge pumped XeCl laser are discussed. Maximum output power of 890mJ at the efficiency of 1.4% was achieved with 35kV charging voltage, 3.4atm of total pressure and 10pps of pulse repetition rate. Optimum HCl pressure is considered to be between 2.5 and 3.5torr.

  • PDF

나노 그래이팅 구조를 갖는 비표지식 바이오센서 성형에 관한 연구 (Replication of label-free biosensor with nano grating structures)

  • 조익현;김병욱;최성우;김경현;성건용;강신일
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.290-293
    • /
    • 2009
  • This paper presents the development of a disposable label-free biosensor for bio molecular interaction analysis. Label-free biosensors have advantages of high performance in sensitivity and short detection time. Among various label-free systems, we introduced biosensor with nano grating structures based on white light source and spectrometer. And to develop high efficiency label-free biosensor, we suggest replicating processes satisfying required specification. We also report a system set-up to evaluate the characteristics of phenomenon shown in this biosensor system.

  • PDF