• 제목/요약/키워드: Ultrasound treatment

검색결과 708건 처리시간 0.032초

A Pilot Clinical Study on the Accuracy and Safety of Ultrasound-guided Gyeontonghyeol (BP-LE6) Acupuncture: A Prospective Randomized, Single Blinded Crossover Study

  • Kim, Jong Uk;Kim, Bo Hyun;Kim, Seok Hee;Shin, Jin Hyeon;Choi, Yoo Min;Song, Beom Yong;Yook, Tae Han;Jeon, Young Ju;Lee, Sanghun
    • Journal of Acupuncture Research
    • /
    • 제36권4호
    • /
    • pp.272-276
    • /
    • 2019
  • Background: The purpose of this study was to assess the accuracy and safety of procedures using ultrasound equipment for acupuncture treatment. Methods: A pilot, prospective randomized, single blinded, crossover clinical study on the accuracy and safety of ultrasound-guided Gyeontonghyeol (BP-LE6) acupuncture treatment was conducted. Patients (n = 13) with shoulder pain were randomly divided into 2 groups. During Visit 1, ultrasound-guided BP-LE6 acupuncture was administered to the experimental group. In the control group, patients received BP-LE6 acupuncture (without checking ultrasound images) by manipulating the ultrasound probe as if administering ultrasound-guided acupuncture. Visit 2 was arranged within 7-14 days and the remaining procedures, other than those administered in Visit 1, were performed. In both the experimental group and control group, the number of needle insertions, and time required for the treatment to result in the patients feeling de-qi was recorded. The numeric rating scale (NRS) score for shoulder pain was recorded before and after the acupuncture treatment. Results: The number of needle insertions was $5.31{\pm}3.50$ times in the experimental group, and $6.62{\pm}3.38$ times in the control group, however, there was no statistically significant difference between the groups (p > 0.05). The mean time required to perform the procedure was $151.54{\pm}48.59$ seconds in the experimental group and $86.69{\pm}37.17$ seconds in the control group, which was statistically significantly different (p < 0.05). The changes observed in numerical rating scale scores between groups were not statistically significantly different. Conclusion: Although there was no statistically significant difference, administering acupuncture using ultrasound guidance may lead to accurate needling with a reduced number of needle insertion attempts. A large-scale clinical study of better design should be conducted in the future.

Adjuvant로 유발된 관절염의 흰쥐에서 초음파와 고전압 맥동 전류 치료의 효과 (Effects of Ultrasound and High-Voltage Pulsed Current on Adjuvant-Induced Arthritis in Rats)

  • 이동진;이동엽;황돈영
    • 한국전문물리치료학회지
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2006
  • The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of $.1m{\ell}$ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in $.1m{\ell}$ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with $.5W/cm^2$ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and $50{\mu}s$ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.

  • PDF

밤껍질 추출물에 의한 면직물 기능성 가공 시 초음파 보조처리의 영향 (Effect of Ultrasound Treatment on Finishing of Cotton Fabrics using Chestnut Shell Extract)

  • 홍경화
    • 한국의류학회지
    • /
    • 제48권2호
    • /
    • pp.300-311
    • /
    • 2024
  • Amid global environmental concerns, initiatives to adopt sustainable industrial processes have garnered significant attention in diverse sectors. Efforts have centered on utilizing natural resources as dyeing and functionalizing agents in the textile industry. However, the limited color fastness and functional endurance of natural compounds remains a substantial challenge. This research investigated whether ultrasound could enhance the finishing effect of natural compounds on cotton fabrics. Chestnut shell extract was prepared and applied to cotton fabrics using a pad-dry-cure technique, with concurrent application of ultrasonic power. Once integrated into the fabrics, the chestnut shell extract exhibited prolonged health benefits for users. The findings demonstrated that ultrasound treatment during the finishing process facilitated the diffusion of natural compounds from the chestnut shell extract into the fabric structure, resulting in a substantial enhancement of the finishing effect, notably augmenting the antibacterial properties of the treated cotton fabrics.

초음파와 전기장 처리에 의한 하수슬러지 탈수성 향상 (Enhancement of Dewaterability of Sewage Sludge by Ultrasonification and Electric Field Treatment)

  • 모우종;한지선;안창민;윤순욱;석희정;김창균
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.23-30
    • /
    • 2013
  • 슬러지 처분비용은 하수처리장 운영에 있어서 중요한 경제적 요소이다. 더욱이, 2013년부터 유기성 폐기물의 해양투기가 금지되면서 대부분의 슬러지가 육상 처리 되어야 하기 때문에 슬러지의 발생량을 줄이는 것이 시급한 상황이다. 본 연구에서는, 초음파와 전기장 처리에 의한 하수슬러지의 탈수성 향상을 확인하고자 하였다. 슬러지는 pilot-scale의 전처리 장치로 초음파와 전기장 단독처리 그리고 초음파 및 전기장 병합처리 되었으며, 처리 후 lab-scale 필터프레스 장치로 탈수되었다. 실험한 초음파 에너지 밀도 범위는 225~1,200 kJ/L였고 전기장 처리장치는 4.5~24 kJ/L였다. 초음파 단독처리와 초음파 및 전기장 병합처리 된 슬러지의 탈수 cake 함수율은 에너지 밀도 1,200 kJ/L일 때, 처리하지 않은 슬러지보다 각각 10~12% 감소하였으며 이 때 슬러지 함수율은 65~66%였다. 초음파 및 전기장 병합처리가 초음파 단독처리보다 탈수된 슬러지 cake의 함수율을 낮추는데 효과적이었으나, 전기장 단독처리의 경우 에너지 밀도가 낮아 함수율의 변화는 거의 없었다.

Lidocaine 음파영동에 의한 표면마취 및 전달마취 효과 (The Effect of Topical and Conduction Anesthesia by Phonophoresis with Lidocaine)

  • 정대인;윤세원;최석주;이정우;정진규;김태열
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.63-83
    • /
    • 2006
  • This study conducted the following experiment to examine anesthetic effects of 500 kHz ultrasound with lidocaine. Clinical experiment was conducted to compare local anesthetic effects by ultrasound frequencies and drugs with 40 normal adults and it divided subjects into experimental group (I) applying only ultrasound, ointment group (II) applying only lidocaine, phonophoresis group of 1 MHz (III), phonophoresis group of 500 kHz lidocaine (IV) for pain threshold and nerve conduct experiments. Mechanical threshold was measured with von Frey monofilament, thermal pain threshold with halogen lamp and digital thermometer, action potential in median nerve with diagnostic electromyography before and after treatment, and at 30 min., 60 min., 90 min., and 120 min. after treatment. Results of this study can be summarized as follows. Topical anesthesia experiment showed that pain threshold of phonophoresis groups was significantly increased, but there were little differences in ultrasound frequency and drugs among phonophoresis groups. Conduction anesthesia experiment showed that phonophoresis group of 500 kHz using lidocaine had significant difference in pain threshold and sensory nerve conduction compared to ointment group and ultrasound group, but there was no great difference from other phonophresis groups and light nerve block effect was found. It was considered that application of 500 kHz ultrasound using lidocaine will be more effective in deep anesthesia or nerve block than 1 MHz ultrasound. However, researches considering various frequencies, intensities and application hours in low frequency areas including kHz ultrasound are needed to increase deep permeation of drugs.

  • PDF

Ultrasonic-assisted dissolution of U3O8 in carbonate medium

  • Chenxi Hou;Mingjian He ;Haofan Fang;Meng Zhang;Yang Gao;Caishan Jiao;Hui He
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.63-70
    • /
    • 2023
  • Ultrasound-assisted dissolution of U3O8 powder in carbonate solution was explored to determine if and how ultrasound act during the dissolution. The variation of U3O8 solid particles and uranyl complexes under ultrasound treatment and magnetic stirring was observed in carbonate media. The results show that the use of ultrasound can increase the solubility and dissolution rate of U3O8 powder than that under magnetic stirring. The crush of U3O8 particles and the reduction of the activation energy (Ea, kJ/mol) of U3O8 dissolution reaction were observed, which both play an important role in the ultrasonic-assisted dissolution of U3O8 in carbonate-peroxide solution. Meanwhile, there is no observation of the ultrasound effect on the distribution of uranyl species and hydrolysis of uranyl complexes during the ultrasound treatment in carbonate-peroxide solution. Although the generation of ·OH radicals under ultrasound (22 ± 2 kHz) was observed, the oxidation of ·OH had little effect on the dissolution of U3O8 in the carbonate-peroxide solution system.

지간 신경종에서 보존적 치료 및 수술적 치료의 임상적 결과 (Clinical Result of Conservative Treatment and Operative Treatment for Interdigital Neuroma)

  • 이진우;한승환;서동석
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.31-36
    • /
    • 2006
  • Purpose: To evaluate the usefulness of ultrasound and MRI in diagnosing Morton's Neuroma, and the effect and significance of stepwise treatment. Materials and Methods: Out of all patients suspected of Morton's neuroma through history taking and physical examination, 77 patients (84 feet, 95 lesions) in whom Morton's neuroma was confirmed by ultrasound or MR imaging study or was clinically suspected with negative imaging studies, and followed up for over 3 months were included. In all cases, history taking and imaging study were done, and by comparison with operative findings of the patients, the sensitivity of ultrasound and MRI was checked. Postoperative evaluation was done using the AOFAS scale. The patient's satisfaction was also examined. Results: Morton's neuroma occurred most frequently at the $3^{rd}$ web space of the foot (56%), followed by the $2^{nd}$ web space (44%). Out of 15 cases suspected of morton's neuroma through ultrasound study, 13 were pathologically positive showing a sensitivity of 85.7%. Out of 16 cases suspected of morton's neuroma through MRI, 14 were pathologically positive showing a sensitivity of 83.3%. There was no significant difference in sensitivity between the two imaging modalities. Conclusion: In diagnosing Morton's neuroma, ultrasound examination had a similar sensitivity with MRI, therefore can be used as a screening study.

  • PDF

흰쥐의 급성기 창상치유에 맥동초음파와 냉 적용이 미치는 효과 (The Effects of Pulsed Ultrasound Treatment and Cold Therapy in the Process of Acute Wound Healing)

  • 김태윤;조남정;정화수;김문수
    • 대한임상전기생리학회지
    • /
    • 제5권2호
    • /
    • pp.23-33
    • /
    • 2007
  • Summary of background data: At the wound from life of the human being very regarding at and a healing process the wound in the portion which is important meantime the many research is accomplished and healing process at the wound the research is small very from the physical therapy territory. Purpose: This study was performed to examine the effects of cold therapy and pulsed ultrasound treatment in the process of acute wound healing. To this end, we measured changes in the length of the wounds, and observed tissues through an optical microscope in order to evaluate the healing process of the acute wounds. Methods: We divided twenty Sprague-Dawley rats into four experimental groups of five rats each and treated them for three days after wound creation. Then we extracted tissues from the wounds on day 6th after wound creation and then took them out for hematoxylin-eosin(HE) staining. We measured changes in the length of the wounds every other day. Result: We were able to detect significant statistical differences in the cold therapy and pulsed ultrasound-treated wounds compared with control wounds. We observed tissues through an optical microscope and found the tissues in cold therapy and pulsed ultrasound-treated wounds healed well. Conclusions: Overall results indicated that the use of cold therapy and pulsed ultrasound treatment were effective in the process of acute wound healing.

  • PDF

여성형유방증 치료에 있어서 절제술 전 초음파 지방흡입술의 역할 (The Role of Ultrasound-Assisted Liposuction before a Surgical Excision in the Treatment of Gynecomastia)

  • 강대일;박상우;최재훈
    • Archives of Plastic Surgery
    • /
    • 제37권6호
    • /
    • pp.742-748
    • /
    • 2010
  • Purpose: The method of using ultrasound-assisted liposuction and excision of the remaining glandular tissue is the preferred method for treating gynecomastia and is currently used worldwide. Herein, this article described the role of ultrasound-assisted liposuction before a surgical excision in the treatment of gynecomastia. The cosmetic results were objectively evaluated. Methods: 11 patients (22 breasts) underwent ultrasoundassisted liposuction and suction-assisted lipectomy between April 2007 and January 2009. At the end of the liposuction, the remaining glandular tissue was removed through the incision used for liposuction. We evaluated the cosmetic results using ordinary scale methods on the basis of four categories (recurrence, symmetry, contour irregularity, and scar). Results: The volume of aspirates ranged between 50 and 200 cc per breast and the average weight of tissue removed by excision was 65g per breast. No complications were recorded. Regarding the cosmetic evaluation, the recurrence, contour irregularity, and scar were excellent, the symmetry was good, and the overall results represented all those cases were mostly excellent. Conclusion: Ultrasound-assisted liposuction has many advantages in the treatment of gynecomastia. When excising the remaining glandular tissue, bleeding is decreased by the use of a tumescent technique. The glandular tissue is easily mobilized and excised after being "morselized" with ultrasound-assisted liposuction. The glandular tissue is simply dissected via the suction surface. Compared the residual mound of glandular tissue beneath the nipple and areola to the periphery, it facilitates precise control of the excision.

열처리와 추출방법에 따른 몇 가지 약초의 항산화 활성 (Effects of Heat Treatment and Extraction Method on Antioxidant Activity of Several Medicinal Plants)

  • 장귀영;김현영;이상훈;강유리;황인국;우관식;강태수;이준수;정헌상
    • 한국식품영양과학회지
    • /
    • 제41권7호
    • /
    • pp.914-920
    • /
    • 2012
  • 추출방법에 따른 몇 가지 약초의 항산화 활성 변화를 연구하였다. 총 5가지 약초(우슬, 목통, 두충, 시호, 향부자)에 대해 비가열 초음파추출, 환류추출 및 열처리 초음파추출을 실시하였다. 총 폴리페놀 함량은 환류추출과 열처리 초음파 추출이 비가열 초음파추출보다 높았으며, 두충과 향부자를 제외한 세 시료가 열처리 초음파추출이 환류추출보다 높았다. 총 플라보노이드 함량은 향부자를 제외한 네 시료가 열처리 초음파추출과 환류추출이 비가열 초음파추출보다 더 많았으며, 우슬과 목통을 제외한 세 시료에서 환류추출이 열처리 초음파추출보다 더 많았다. ABTS 라디칼 소거능은 환류추출과 열처리 초음파추출이 비가열 초음파추출보다 작았으며, DPPH 라디칼 소거능은 우슬과 목통을 제외한 세 시료는 환류추출에서 더 높은 활성을 나타내었다. 환원력은 우슬이 가열처리 시 많은 증가를 나타내었으며, 다른 네 시료는 추출방법에 따른 차이가 작았다. 본 실험 결과에 따르면, 약초의 종류에 따라 적합한 추출방법과 전처리를 적용함으로써 높은 항산화 활성을 가진 추출물을 얻는 것이 가능할 것이라 판단된다.