• 제목/요약/키워드: Ultrasound treatment

검색결과 708건 처리시간 0.026초

Properties of Low-Molecular Alginate by Ultrasound

  • Kim Sang-Moo;Park Seong-Min;Lee Keun-Tae;Bae Tae-Jin
    • Fisheries and Aquatic Sciences
    • /
    • 제2권2호
    • /
    • pp.149-154
    • /
    • 1999
  • Response Surface Methodology was applied for optimizing the processing parameters of ultrasound treatment in order to produce low-molecular alginate. The use of ultrasound significantly reduced viscosity of alginate solutions. Suggested parameters of ultrasound treatment for maximum reduction of alginate molecular weight were: specific intensity, 115.81 $W/cm^2$ at 20kHz frequency; treatment time, 35.55 min; temperature, $20.08^{\circ}C$; alginate concentration, $2.5\%$. Low-molecular alginate obtained by ultrasound had two peaks on Sepharose CL-6B gel filtration. The viscosities of control, fraction I, and fraction II at $0.1\%$ concentration and $25^{\circ}C$ were 3.07, 1.23, and 0.82cps, respectively. Molecular weights of control, fraction I, and fraction II alginates were 336,500, 70,400, and 52,800 daltons, and their solubilities were 3, 6, and $14\%$, respectively. The lower molecular weight of alginate, the lower the alcohol precipitation and the higher $Ca^{2+}$ ion binding capacities. Heavy metal ion binding capacities of alginates were high in the following order of Pb, Cd, Zn, and Co.

  • PDF

악안면부에 대한 수종 온냉요법시의 체열변화에 관한 비교연구 (Efficacy of Thermal Therapies in Masseter Area - Thermographic Study -)

  • Sun-Ho Kim;Jung-Pyo Hong;Eui-Hwan Hwang
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.307-315
    • /
    • 1995
  • The purpose of this study was to assess the efficacy of several thermal therapies using ice pack, moist-hot pack and ultrasound, separately and concomitantly and to obtain the background information on the vascular changes after thermophysical therapies. The author had used 15 healthy subjects were examined and the subjects were divide into 5 groups : ice pack, moist-hot pack, ultrasound, ice pack and moist-hot pack, ice pack and ultrasound. Observation were made immediate before and 0,5,10,20,30,45,60,90 minutes after treatment. Thermography was performed in an Agema 870 thermovisio with 0.1$^{\circ}C$ difference of gradual temperature shift. The results were as follows : 1. Using ice pack only, the surface temperature of the masseter region was increased lapse of time, and most remarkably 90 minutes after the treatment. 2. Using moist-hot pack only, the surface temperature of the region was remarkably increased immediately after the treatment, but decreased lapse of time. 3. Using moist-hot pack with ice pack, the surface temperature of the face was remarkably increased immediately after the treatment, and decreased lapse of time, Hyperthermia was maintained for a longer time as compared with the group of moist-hot pack only. 4. Using ultrasound only, the surface temperature of the region was increased gradually, and most remarkably 30 minutes after the treatment, but decreased in the course of time. 5. Using ultrasound combined with ice pack, the surface temperature of the region was gradually decreased until 30 minutes after the treatment, and decrease to some extend at 45 minute. And then a gradual increase observed over the remaining period of the experiment. 6. Hyperthermia were maintained for a long time in the groups using ice pack combined with moist-hot pack and ultrasound as compared with the other groups. Our data suggest that ice pack can promote the efficacy of other thermal therapies.

  • PDF

Efficacy of Lauromacrogol Injection for Ablation of Benign Predominantly Cystic Thyroid Nodules and Related Factors: A Prospective Study

  • Yi Jie Dong;Zhen Hua Liu;Jian Qiao Zhou;Wei Wei Zhan
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.479-487
    • /
    • 2022
  • Objective: To prospectively evaluate the efficacy of lauromacrogol injection for ablation (LIA) of benign predominantly cystic thyroid nodules and its related factors. Materials and Methods: A total of 142 benign predominantly cystic thyroid nodules (median volume, 12.5 mL; range, 0.4-156 mL) in 137 patients (male:female sex ratio, 36:101; mean age ± standard deviation [SD], 49 ± 13 years) were treated with LIA after being confirmed as benign via cytology. The volume reduction rate (VRR) of the nodules and cosmetic score were evaluated during follow-up at 1, 3, and 6 months after treatment and every 6 months thereafter. A VRR of ≥ 50% at the 12-month follow-up was considered to indicate effective treatment. The associations between the clinical factors and nodular ultrasound features, including the initial nodule volume, proportion of solid components, vascularity grade and ineffective treatment (VRR of < 50% at the 12-month follow-up), and regrowth were analyzed. Results: All patients completed follow-up for at least 12 months. The average ± SD follow-up period was 32 ± 11 months (range, 12-54 months). The effective treatment rate was 73.2% (104/142), while the regrowth rate was 12.0% (17/142) at the last follow-up. Grade 2-3 intranodular vascularity in the solid components of the nodules was the only independent factor associated with ineffective treatment, with an odds ratio (reference category, grade 0-1) of 3.054 (95% confidence interval, 1.148-8.127) (p = 0.025). Conclusion: LIA is an effective treatment for predominantly cystic thyroid nodules. Grade 2-3 intranodular vascularity in the solid components of nodules is the only independent risk factor for ineffective LIA.

Transdermal Delivery System of Triamcinolone Acetonide from a Gel Using Phonophoresis

  • Yang Jae-Heon;Kim Dae-Keun;Yun Mi-Young;Kim Tae-Youl;Shin Sang-Chul
    • Archives of Pharmacal Research
    • /
    • 제29권5호
    • /
    • pp.412-417
    • /
    • 2006
  • Triamcinolone acetonide (TA) is a corticosteroid that is used in the systemic and topical treatment of many inflammatory diseases. In this study, a phonophoretic drug delivery system was designed to enhance the TA permeability and the influence of ultrasound was examined. In order to establish the transdermal delivery system for TA, a hydrophilic carbopol gel containing TA was prepared after adopting phonophoresis. A permeation study through mouse skin was performed at $37^{\circ}C$ using a Franz diffusion cell, and the ultrasound treatment was carried out for 10 h. The level of TA permeation through the skin was evaluated under various ultrasound conditions including the frequency (1.0, 3.0 MHz), intensity (1.0, $2.5W/cm^2 $), and duty cycle (continuous, pulse mode) using a 0.5% TA gel. The highest permeation was observed under the ultrasound treatment conditions of low frequency, high intensity, and in continuous mode.

초음파 영상에서 급성 위점막 병변으로 진단된 환자에 대한 한의치료 치험 1례 (A Case Report on Korean Medicine Treatment for a Patient Diagnosed with Acute Gastric Mucosal Lesion on Ultrasound Imaging)

  • 김채은;백태현
    • 대한한방내과학회지
    • /
    • 제44권6호
    • /
    • pp.1354-1361
    • /
    • 2023
  • Objectives: This study reports a clinical case that showed improvement in the symptoms of a patient with acute gastric mucosal lesion (AGML) through ultrasound. Methods: A 90-year-old woman with AGML was treated with Korean medicine treatments, including Hyangsapyeongwisan Soft Ext, acupuncture, and moxibustion. The responses before and after treatment were evaluated using ultrasound imaging and the numerical rating scale (NRS). Results: After treatment, ultrasound imaging showed improvement in gastric mucosa thickness, from 1.45 cm to 0.53 cm at the anterior wall and from 1.25 cm to 0.36 cm at the posterior wall. The NRS scores for epigastric pain, nausea, and dizziness all decreased, and the symptoms of diarrhea disappeared. Conclusion: This study suggests that Korean medicine treatment can be a therapeutic option in treating the symptoms of patients with AGML.

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

저강도 초음파 치료기기의 안전성 및 성능평가 가이드라인 수립을 위한 연구 (A Study on the Safety and Performance Test Guideline of Low Intensity Therapeutic Ultrasound Device)

  • 김주영;김재영;노시철;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.162-168
    • /
    • 2015
  • In this study, we suggested the performance and safety testing guideline for low intensity pulsed ultrasound (LIPUS) represented by the ultrasound fracture treatment device and cartilage treatment device and low intensity focused ultrasound (LIFU) represented by ultrasonic face lifting device. For these study, the international standards and management regulations of Korea, Japan and United State were analyzed. And the usefulness and applicability were evaluated by testing with commercial equipment and reflecting the views of the industry and experts. As a result of this study, the safety and performance test guidelines for low intensity therapeutic ultrasound device were proposed by presenting the 10 items for LIPUS and 12 items for LIFU. The suggested guidelines are considered a high utilization in the domestic testing and approval authorities. And they are also thought to be useful to new technology development.

과배란처리 한우에서 초음파 유도에 의한 난자채란에 대한 연구 (Transyaginal Ultrasound-guided Oocytes Collection in Superovulated Korean Native Cows)

  • 이효종;강태영;조성근;박준규;손우진;최민철;최상용
    • 한국수정란이식학회지
    • /
    • 제12권2호
    • /
    • pp.195-202
    • /
    • 1997
  • The present study was carried out to evaluate the effect of superovulation treatments on ovarian responses, oocyte recovery rates and grades of collected oocytes using an ultrasound-guided transvaginal approach in Korean native cows. Superovulation in cows was induced with two different regimenes: 1) FSH-decreasing dose(n=8): the cows were received twice per day for three days of the total dose of 400 mg of FSH-p, 2) FSH-single dose(n=9): the cows were administrated a single dose of 400 mg of FSH-p in 25% PVP. The Observation of visible follicles and collection of oocytes were performed 12 hours following the last FSH in FSH-decreasing dose group and 48 hours after the FSH-single dose injection. All visible follicles larger than 6 mm were punctured and aspirated with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use. The mean number of visible follicles(> 6 mm) was significantly(P<0.05) higher in the FSH-decreasing dose treatment (22.811.9) and FSH-single dose treatment (20.612.0) groups than the non-treatment group(7.0$\pm$8). The mean recovery rate of oocytes was not significantly(P<0.05) different between the treatment and control groups, but the mean number of collected oocytes was significantly(P<0.05) higher in the FSH-decreasing dose treatment( 12.611.5) and FSH-single dose treatment (11.813.6) groups than the non-treatment group(3.7$\pm$0.5). In conclusion, the FSH-single dose treatment at superovulation in cows for ultrasound-guided aspiration might increase the number of aspiratable follicles and the recovery rate of follicular oocytes as the FSH-decreasing dose treatment.

  • PDF

액취증 치료에 있어서 초음파 지방흡입술이 아포크린 한선과 에크린 한선에 미치는 효과 (The Effect of Ultrasound Assisted Liposuction for Axillary Osmidrosis on Apocrine and Eccrine Glands)

  • 천지선;김창윤;양정열
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.62-66
    • /
    • 2008
  • Purpose: Axillary osmidrosis is a distressing disorder characterized by unpleasant odor from axillary area and it is mainly associated with apocrine glands but also associated with eccrine glands. For surgical treatment of osmidrosis, recently ultrasound assisted liposuction(UAL) had been performed for many patients. According to the recent studies about ultrasound assisted liposuction for the treatment of osmidrosis, histologic studies about apocrine gland had been applied for 35 cases, but there were rare mention about eccrine gland and the relationship between two glands. The purpose of this article is to evaluate the effect of ultrasound assisted liposuction for the treatment of axillary osmidrosis on apocrine and eccrine glands. Methods: From January 2004 to January 2007, 35 patients underwent ultrasound assisted liposuction for the treatment of osmidrosis and 5 patients underwent histologic studies. Histologic examinations were performed before and after ultrasound assisted liposuction and each biopsy was performed in central axillary area. The volume ratio of both glands, presence of degeneration were examined. And in aspirates, distribution and density of both glands and their morphological changes were examined. Results: Preoperative biopsy results showed average volume ratio of apocrine glands to eccrine glands was 65 : 35. According to the postoperative biopsy results, the volume of apocrine glands in dermis were significantly reduced and glands were degenerated, but the volume of eccrine glands were slightly reduced and glands were mildly damaged. And the average volume ratio of two glands was 20 : 80. According to biopsy results of aspirates, the volume ratio of two glands was 85 : 15 and apocrine glands had significantly greater proportion. Conclusion: By comparison of each biopsy result, apocrine glands were more significantly reduced and degenerated than eccrine glands in all 5 cases. However, further studies with large sample sizes and close examinations are required.

An Application of High-Power Ultrasound to Rubber Recycling

  • Hong, Chang-Kook;Isayev, A.I.
    • Elastomers and Composites
    • /
    • 제38권2호
    • /
    • pp.103-121
    • /
    • 2003
  • The application of powerful ultrasound to rubber recycling is a very recent field of study. An ultrasonic field creates high frequency extension-contraction stresses by acoustic cavitation. The breakdown of rubber network occurs primarily around pulsating cavities due to the highest level of strain produced by high-power ultrasound. Stronger reductions of cross-link density were observed at a higher pressure, indicating an important role of pressure during ultrasonic recycling. Visible bubbles were observed during ultrasonic treatment as a proof of acoustic cavitation. Shearing effect has a significant influence on improving the efficiency of ultrasonic treatment. After the ultrasonic treatment, the cross-link densities of NR/SBR blends were lower than those of NR and SBR due to the reduced degree of unsaturation and chemical reactions. Carbon black fillers increase the probability of bond scission during ultrasonic treatment, due to the restricted mobility. The mechanical properties of ground tire rubber (GRT)/HDPE blends were improved by ultrasonic treatment and dynamic revulcanization. Ultrasonic treatment of GRT in the presence of HDPE matrix was found to give better mechanical properties due to the chemical reactions between rubber and plastic phases.