• 제목/요약/키워드: Ultrasound measure

검색결과 152건 처리시간 0.022초

초음파를 이용한 골다공증 진단 (Ultrasonic Diagnosis of Osteoporosis)

  • 이강일;윤석왕
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.64-72
    • /
    • 2010
  • Osteoporosis is a skeletal disease characterized by two factors: reduced bone mass and microstructure disruption of bone tissue. These symptoms increase bone fragility and can contribute to eventual fracture. In recent years, quantitative ultrasound (QUS) technologies have played a growing role in the diagnosis of osteoporosis. Most of the commercial bone sonometers measure speed of sound and/or broadband ultrasound attenuation at peripheral skeletal sites. However, QUS parameters are purely empirical measures that have not yet been firmly linked to physical parameters, such as bone strength or porosity, and the underlying physics for their variations in cancellous bone is not well understood yet. This paper reviews the QUS technologies for the diagnosis of osteoporosis and also addresses several theoretical models, such as the Biot model, the scattering model, the stratified model, and the modified Biot-Attenborough model, for ultrasonic wave propagation in bone.

박쥐의 먹이 탐지 전략을 모방한 초음파 센서의 물체 위치 추정 (Ultrasound Echolocation Inspired by a Prey Detection Strategy of Big Brown Bats)

  • 박상욱;김대은
    • 제어로봇시스템학회논문지
    • /
    • 제18권3호
    • /
    • pp.161-167
    • /
    • 2012
  • It is known that big brown bats can distinguish echo of a prey at various angles. In this paper, we suggest a new object localization strategy using ultrasonic echolocation. We calculate the relative energy ratio between a high frequency component of ultrasound signal and a low frequency component of ultrasound signal for a target object. We found the measure depends on bearing angle of the object in space. We also tested energy ratio of echoed FM ultrasound signals depending on frequency, based on cross-correlation. It can determine the relative angular position of objects even though the reflected signals are congested form each object.

초음파와 근막이완술이 긴장형 두통환자의 뇌혈류 속도에 미치는 영향 (The effects of ultrasound and myofascial release therapy on blood velocity of cranial artery in tension-type headache subjects)

  • 한종만;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제15권1호
    • /
    • pp.196-209
    • /
    • 2003
  • The aim of study was compared with the possible role of cranial artery in headache pathogenesis each 2 group (group I : ultrasound therapy alone, group II : myofascial release therapy alone)- divided each 5 tension- type headache patients. Each group were applied ultrasound therapy for 5 minuets and myofascial release therapy for 15 minuets in occipital portion. The study carried out to determine the effects of ultrasound and myofascial release on the cranial arteries velocity from November 11, 2001 to March 29, 2002 the objects were 10 patients who having the tension-type headache at H-hospital. Transcranial doppler ultrasonograpy(TCD) is new non-invasive applicable method to evaluate flow velocities of intrans cranial and extracranial cerebral arteries. TCD was peformed with standard method to measure the Mean Flow Velocity(MFV) of the middle and posterior cerebral arteries, the vertebral arteries.

  • PDF

Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques

  • Junghoan Park;Jeong Min Lee;Gunwoo Lee;Sun Kyung Jeon;Ijin Joo
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.13-29
    • /
    • 2022
  • Nonalcoholic fatty liver disease, characterized by excessive accumulation of fat in the liver, is the most common chronic liver disease worldwide. The current standard for the detection of hepatic steatosis is liver biopsy; however, it is limited by invasiveness and sampling errors. Accordingly, MR spectroscopy and proton density fat fraction obtained with MRI have been accepted as non-invasive modalities for quantifying hepatic steatosis. Recently, various quantitative ultrasonography techniques have been developed and validated for the quantification of hepatic steatosis. These techniques measure various acoustic parameters, including attenuation coefficient, backscatter coefficient and speckle statistics, speed of sound, and shear wave elastography metrics. In this article, we introduce several representative quantitative ultrasonography techniques and their diagnostic value for the detection of hepatic steatosis.

초음파를 이용한 Bladder형태에 따른 잔뇨량 측정의 정확도 연구 (A Study on the Accuracy of Measurement of Residual Urine Amount depending on the Bladder form using Ultrasonic)

  • 김연민;박태훈;김진혁;김수지;조다훈;허진영;한동균
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to increase the accuracy of the diagnosis of benign prostatic hyperplasia by presenting a method that can accurately measure the residual urine amount of the bladder by using an ultrasound image. Agar powder, Propanol and distilled water were used as materials for making a phantom. In order to measure the volume, a $10m{\ell}$ cylinder, syringe and beaker were used. The image was obtained by scanning phantoms produced into six shapes. Each constant value was obtained by using the expression designed to measure the residual urine amount of the bladder and was compared and analyzed. The measuring method of Bladder volume was presented and a constant value for each shape was obtained and five observers measured it five times. According to the results of clinical application, the errors of Ellipse-beanbag, Shield-shield were 11.0%, 18.2%, respectively. Constant values depending on the shape of each phantom were presented in order to accurately measure the volume of the bladder in measuring the amount of residual urine for the diagnosis of benign prostatic hyperplasia. The accuracy of the volume using this was verified statistically(p > 0.05). Therefore, it is considered to be useful in diagnosing benign prostatic hyperplasia by using the ultrasound imaging measuring method presented.

  • PDF

초음파 치료 시 초음파 세기 변화에 따른 생리적 효과 연구 (A Study of Ultrasound Rehabilitation Therapy: Physiological Effects by Change of Ultrasound Intensity)

  • 김성민;이만표;최병철;최상혁;배하석;정회승;박성윤
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.40-45
    • /
    • 2008
  • Therapeutic ultrasound which is developed for rehabilitation therapy have already been used for healing joint contracture, synechia, acute and chronic inflammatory diseases. Medical devices for pain-relief and healing using therapeutic ultrasound are actively being developed. This study measured the change of PTT with the transmitted ultrasound through the human body to find out the increase of compliance of blood vessels. Measurement method of PTT in this study is employed as useful ways to acquire physiological information of patients in the clinical case in order to measure the change of mechanical characteristics of blood vessels. This study confirmed the PTT change of rehabilitation patients through the thermal effects of ultrasound by using PTT and also found that it is possible to increase PTT by adjusting the warm water and ultrasound. The increase of PTT means the decrease of the pulse wave velocity from the cardiovascular system to the peripheral arteries. The physiological effects occurred using the warm water and ultrasound.

경부근막동통증후군 환자에게 근막이완요법과 초음파치료의 비교 (A Comparison of Myofascial Release and Ultrasound in Patients with Myofascial Pain Syndrome on Neck)

  • 김종우;현상욱;서현규
    • 대한정형도수물리치료학회지
    • /
    • 제15권2호
    • /
    • pp.15-24
    • /
    • 2009
  • Objectives : The purpose of this study is to compare the effectiveness between myofascial release technique and ultrasound in subjects with myofascial pain syndrome. Method : Twenty subjects with myofascial pain syndrome were randomly assigned to a myofascial release technique group(n=10) or an ultrsound group(n=10). The Cervical Range of Motion(C-ROM) instrument was used to measure cervical range of motion. Electromyography(EMG) was used to measure muscle power sternocleidomastoid and upper trapezius. Result : The result of this study shows there were no significant differences in ROM increase and muscle power increase between the myofascial release technique group and the ultrasound group. In the group with Myofascial Release Technique, the average score was $61.40{\pm}11.12$ in SCM flexion of C-ROM and $127.87{\pm}4.24$ in Rt. upper trapezius extension of EMG. In the group with ultra sound, the average score was $68.60{\pm}10.02$ in SCM flexion of C-ROM and $131.50{\pm}5.45$ in Rt. upper trapezius extension of EMG. Conclusion : The results suggest that there was no significant difference between two therapeutic techniques.

  • PDF

초음파에 의한 전완 국소 온도와 정중 운동 신경전도 속도의 변화 (Alteration of Forearm Local Temperature and Median Nerve Conduction Velocity by Therapeutic Ultrasound in Healthy Adult Subjects)

  • 전차선;김택연
    • 대한정형도수물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 2006
  • PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

  • PDF

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

ATP meter를 이용한 초음파 탐촉자의 오염도 분류 (Ultrasound Probe Contamination Classification using ATP Meter)

  • 하명진;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.