• Title/Summary/Keyword: Ultrasound imaging

Search Result 570, Processing Time 0.023 seconds

Forward-Looking Ultrasound Imaging Transducer : II. Fabrication and Experimental Results

  • Lee, Chankil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2E
    • /
    • pp.76-84
    • /
    • 1996
  • The experimental testing results of the large-scale version of a forward-looking ultrasound imaging catheter(FLUIC) are presented, along with the fabrication techniques used, experimental methods, and comparisons of the measured and simulated results. The transducer model is verified by measuring the electrical impedance of the transducer. The pulse width, beamwidth, and the dynamic range for both transmit and pulse-echo response of the fabricated FLUIC are also analyzed. The experimental results conformed its forward-looking imaging capability and the sources of discrepancies between the simulated and experimental beam profiles are addressed.

  • PDF

The Effects of Task-Oriented Training for Left Trunk Flexion Pattern Using Real-Time Ultrasound Imaging -A Single-Subject Experimental Study- (편측무시 환자에게 실시간 초음파 영상을 이용한 왼쪽 몸통 굽힘 패턴을 적용한 과제지향적 훈련의 효과 -단일 사례 연구-)

  • Kim, Ji-Seon;Ki, Kyong-Il;Kang, Tae-Woo
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • Purpose: This study investigates the effects of task-oriented training for a left trunk flexion pattern using real-time ultrasound imaging in a stroke patient with unilateral neglect symptoms. Methods: This study used the ABA experimental design, which is a single-subject research method among individual case research methods. For the ABA experimental design, changes in the degree of unilateral neglect, balance ability, and the thickness of the lateral abdominal muscle were visually analyzed during the baseline process, in the intervention period, and after the intervention. The experiments were performed 24 times in total for 8 times in each of the 3 periods. The unilateral neglect was measured using the Albert test, balance ability was measured using the Berg balance test, and the thickness of the lateral abdominal muscle was measured using ultrasound imaging. The subject was a 50-year-old male patient with unilateral neglect caused by right cerebral hemorrhage. He performed task-oriented training for a voluntary left trunk flexion pattern using real-time ultrasound imaging during the intervention period. Results: The result of comparing the data collected during the intervention period with the data point average of the baseline process showed that balance ability improved and the tendency line was above the baseline. The tendency line of unilateral neglect was below the baseline and showed a decreasing tendency. The thickness of the lateral abdominal muscle showed an increasing trend and the tendency line was above the baseline. Conclusion: The results of this study suggest that the task-oriented training for left trunk flexion pattern using real-time ultrasound imaging has a beneficial effect on balance ability, the degree of unilateral neglect, and the strength of the lateral abdominal muscle in unilateral neglect patients.

Ultrasound Imaging and Electrophysiological Characteristic According to Activity Levels of Myofascial Trigger Point (근근막 발통점의 활성도에 따른 초음파 영상구조 및 전기생리학적 특성)

  • Kim, Hyun-Jin;Kim, Su-Hyun;Park, Young-Hyun;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.8 no.1
    • /
    • pp.23-29
    • /
    • 2010
  • Purpose : This study is to offer clinical primary data that examines the change of imaging structure and the quantitative evaluation of muscle activity on myofascial trigger points. This study examines neuromuscular physiological characteristic by comparing the differences in physical findings, pressure pain threshold, imaging, and electrophysiological characteristics in latent and active myofascial trigger points muscle and normal muscle through the following experimental procedures. Methods : The participants for the study were thirty-three adults in their twenties. We divided three groups into normal, latent and active myofascial trigger points groups by physical findings. We analyzed the results of measured pressure pain, threshold for pain, ultrasound imaging perform for structure characteristic of muscle, surface EMG according to type of muscle contraction for function of muscle contraction. Results : Significant differences were indicated in pressure pain threshold (p<0.05). Significant differences were discovered in the ultrasound imaging analysis. There were increases in muscle Echogenicity white area index (p<0.001). There were significant differences that decrease in %MVIC (p<0.05), increase in MDF (p<0.05). Conclusion : From these results, active rnyotascial trigger points muscle showed quality deterioration on ultrasound imaging and decreased function of muscle contraction, increased motor unit action potential of II type fiber, and electrophysiologically. Imaging structure and neuromuscular physiological characteristic can be diagnostic and quantitative analytical techniques for myofascial pain syndrome and a primary factor that reflected in physical therapy intervention.

Clinical Result of Conservative Treatment and Operative Treatment for Interdigital Neuroma (지간 신경종에서 보존적 치료 및 수술적 치료의 임상적 결과)

  • Lee, Jin-Woo;Han, Seung-Hwan;Suh, Dong-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.31-36
    • /
    • 2006
  • Purpose: To evaluate the usefulness of ultrasound and MRI in diagnosing Morton's Neuroma, and the effect and significance of stepwise treatment. Materials and Methods: Out of all patients suspected of Morton's neuroma through history taking and physical examination, 77 patients (84 feet, 95 lesions) in whom Morton's neuroma was confirmed by ultrasound or MR imaging study or was clinically suspected with negative imaging studies, and followed up for over 3 months were included. In all cases, history taking and imaging study were done, and by comparison with operative findings of the patients, the sensitivity of ultrasound and MRI was checked. Postoperative evaluation was done using the AOFAS scale. The patient's satisfaction was also examined. Results: Morton's neuroma occurred most frequently at the $3^{rd}$ web space of the foot (56%), followed by the $2^{nd}$ web space (44%). Out of 15 cases suspected of morton's neuroma through ultrasound study, 13 were pathologically positive showing a sensitivity of 85.7%. Out of 16 cases suspected of morton's neuroma through MRI, 14 were pathologically positive showing a sensitivity of 83.3%. There was no significant difference in sensitivity between the two imaging modalities. Conclusion: In diagnosing Morton's neuroma, ultrasound examination had a similar sensitivity with MRI, therefore can be used as a screening study.

  • PDF

Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application (휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성)

  • Kang, Dong Heon;Chae, Mi Na;Hong, Se Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Development of a Mobile Ultrasound Scanner for Point-of-care Applications (현장 진단 응용을 위한 모바일 초음파 스캐너 개발)

  • Cho, Jeong;Sohn, Hak-Yeol;Kim, Gi-Duck;Song, J.H.;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.66-78
    • /
    • 2009
  • A mobile ultrasound scanner developed for use in point-of-care applications is introduced, which can not only provide ultrasound images but can also measure various bio-signals. The mobile ultrasound scanner is also designed to meet the demanding requirements for point-of-care diagnosis, such as battery-powered operation, portability in terms of size and weigh, and real-time wireless communications capability for remote diagnosis. To meet these requirements, an efficient beamforming method for high resolution imaging with a small number of active elements, a hardware efficient beamformer architecture, and echo processing algorithms with greatly reduced computational complexity have been developed. Experimental results show that the prototype mobile ultrasound scanner is fully functional and satisfies most of the design requirements.

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

MRI Features for Prediction Malignant Intra-Mammary Lymph Nodes: Correlations with Mammography and Ultrasound

  • Kim, Meejung;Kang, Bong Joo;Park, Ga Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.135-149
    • /
    • 2022
  • Purpose: To assess clinically significant imaging findings of malignant intramammary lymph nodes (IMLNs) in breast cancer patients and to evaluate their diagnostic performance in predicting malignant IMLN. Materials and Methods: A total of 110 cases with IMLN of BI-RADS category 3 or more, not typical benign IMLN, in MR of breast cancer patients between January 2016 and January 2021 were retrospectively reviewed. After excluding 33 cases, 77 cases were finally included. Among them, 58 and 19 were confirmed as benign and malignant, respectively. Qualitative and quantitative MR imaging features of the IMLN were retrospectively analyzed. Sizes and final assessment categories of IMLN on MRI, mammography, and ultrasound were reviewed. Diagnostic performances of imaging features on MRI, mammography, and ultrasound were then evaluated. Results: For qualitative MR features, shape, margin, and preserved central hilum were significantly different between benign and malignant groups (P < 0.05). For quantitative MR features, long diameter over 6 mm, short diameter over 4 mm, and cortical thickening over 3 mm showed high sensitivities in predicting malignant IMLNs (89.5%, 94.7%, and 100%, respectively). Size exceeding 1 cm showed high specificity and accuracy in predicting malignant IMLN on MR, mammography, and ultrasound (91.4% and 80.5%; 96.6% and 79.25; 98.3% and 80.5%, respectively). Conclusion: Various MR imaging features and size can be helpful for predicting malignant IMLN in breast cancer patients.

Molecular Imaging of Stretch-Induced Tissue Factor Expression in Carotid Arteries with Intravascular Ultrasound

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • Molecular imaging with targeted contrast agents enables tissues to be distinguished by detecting specific cell-surface receptors. In the present study, a ligand-targeted acoustic nanoparticle system is used to identify angioplasty-induced expression of tissue factor by smooth muscle cell within carotid arteries. Pig carotid arteries were overstretched with balloon catheters, treated with tissue factor-targeted or a control nanoparticle system, and imaged with intravascular ultrasound before and after treatment. Tissue factor-targeted emulsion bound and increased the echogenicity and gray-scale levels of overstretched smooth muscle cell within the tunica media, versus no change in contralateral control arteries. Expression of stretch-induced tissue factor in carotid artery media was confirmed by immunohistochemistry. The potential for abnormal thrombogenicity of balloon-injured arteries, as reflected by smooth muscle expression of tissue factor, was imaged using a novel, targeted, nanoparticulate ultrasonic contrast agent.

  • PDF

An Improved Second-odrer Sampling Method for Digital Beam Forming in Ultrasound Imaging Systems (초음파 영상 시스템에서 디지탈 Beam Forming을 위한 개선된 2차 샘플링 방법)

  • 조완희;안영복
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.1
    • /
    • pp.110-119
    • /
    • 1995
  • The lateral resolution in an ultrasound imaging system is one of the most important factors for quality of the image and is determined by the beam focusing. For the better lateral resolution SDF(Sampled Delay Focusing) capable of digital focusing was proposed. The second-order sampling, one of band-width sampling methods, is suggested as being the best suitable for SDF because it allows total digital processing and is simple and economical. By proving that it introduces too much error, this article shows the second-order sampling is not appropriate for sampling of the wide-band signal generally used in ultrasound imaging systems. Also, this article suggests new sampling methods that maintain the advantages and reduce the unavoidable errors of the second-order sampling method. From computer simulation it is expected that the proposed methods reduce the errors of the second-order sampling method and can be used in real applications.

  • PDF