• Title/Summary/Keyword: Ultrasound head

Search Result 96, Processing Time 0.019 seconds

Electromyographic Analysis of Wrist Flexors by the Shape of Ultrasound Head (초음파 도자의 모양에 따른 손목굽힘근의 근전도 분석)

  • Kim, Won-Ho;Kim, Jong-Man;Park, Hyung-Ki;Park, Eun-Young
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.9-15
    • /
    • 2007
  • The purpose of this study was to investigate electromyographic activities of the flexor digitorum superficialis (FDS) and the flexor carpi ulnaris (FCU) by the shape of the ultrasound head. Twelve healthy subjects participated and performed ultrasound therapy with a round head and a long handled head during each 5-minute application. Electromyographic activities of the FDS and FCU were recorded by surface electrodes and normalized by maximal voluntary isometric contraction (MVIC) values. There was no difference in the muscular fatigue of FDS and FCU as determined by the shape of the ultrasound head (p>.05). Without the shape of head, the mean power frequency decreased with the time. There also was no difference in %MVIC of the FDS and FCU as determined by the shape of the ultrasound head (p>.05), but the force exerted exceeded 20%MVIC. There was however a significant difference in the amount of cumulative workload of the FDS and FCU as determined by the shape of ultrasound head (p<.05). The workload was however not affected by the shape of the ultrasound head. Constant static grasp of ultrasound transducer head during ultrasound therapy is considered a high risk factor of work-related musculoskeletal disease.

  • PDF

The Influence of the Pattern of Gripping the Ultrasound Head on the Activity of Upper Limb Muscles (초음파 도자를 쥐는 방법이 팔 근육의 근활성도에 미치는 영향)

  • Choi, Seok-Ho;Yi, Chung-Hwi;Jeon, Hye-Sun;Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.28-37
    • /
    • 2013
  • This study examined differences in the activity of upper limb muscles according to how an ultrasound head is gripped. Twenty-two adult males were participated in the study. Each participant was asked to apply ultrasound treatment on to a lump of pork meat by two different ultrasound head grip patterns: spherical and cylindrical grips. Muscle activity was measured in the extensor carpi radialis longus (ECRL), flexor carpi ulnaris (FCU), and pronator teres (PT), triceps brachii (TB), middle deltoid (MD), and upper trapezius (UT) muscles. There were no significant differences in the EMG signals of any muscle according to the ultrasound head grip pattern (p>.05). There were significant differences in the EMG signal of each type of muscle (p<.05). The EMG signal of UT was the lowest and that of TB was lower than ECRL and FCU. There were interactions between ECRL and FCU, between ECRL and PT, between FCU and ECRL, and between FCU and MD. The EMG signal of ECRL using the cylindrical head was low and that of FCU with the cylindrical head was high, while the opposite was the case with the spherical head ($p_{adj}$ <.05/15). The results of this study indicate that the wrist muscles worked actively when the participants applied ultrasound therapy using both spherical and cylindrical heads. A spherical head might induce imbalanced muscle activity among the wrist muscles, leading to deviation of the wrist joint. Therefore, the cylindrical head is recommended for ultrasound therapy because it produced a constant, repeated force.

Clinical Result of Combined Radiotherapy and Hyperthermia Induced by 915 MHz Microwave and Ultrasound in Locally Advanced Malignant Tumors of Head and Neck (915 MHz 극초단파 및 초음파를 이용한 온열치료와 방사선치료 병합치료에 의한 두경부암의 치료성적)

  • Koh Kyoung-Hwan;Park Young-Hwan;Cho Chul-Koo;Yoo Seong-Yul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.1
    • /
    • pp.40-45
    • /
    • 1990
  • Thirty five lesions of 35 patients with locally advanced malignant tumors of head and neck were received thermoradiotherapy with ultrasound and/or 915 MHz microwave. Most of all patients were failed with previous conventional therapeutic trial. Hyperthermia had been done immediately after radiotherapy, twice a week, $43^{\circ}C$ for one hour and radiotherapy had been done 5 fractions per week with a fraction size of 2 Gy up to total 30 to 60 Gy. Conclusions are as follows; 1) Total response rate (CR+PR) of thermoradiotherapy with microwave and ultrasound was 80%. 2) Tumor depth, minimum temperature of tumor center, number of heat fraction and irradiation dose were statistically significant factors affecting response. 3) Hyperthermia with microwave and ultrasound can be used efficiently to control locally advanced malignant tumors in head and neck whether previously received near tolerance dose of radiotherapy or not.

  • PDF

Precise segmentation of fetal head in ultrasound images using improved U-Net model

  • Vimala Nagabotu;Anupama Namburu
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.526-537
    • /
    • 2024
  • Monitoring fetal growth in utero is crucial to anomaly diagnosis. However, current computer-vision models struggle to accurately assess the key metrics (i.e., head circumference and occipitofrontal and biparietal diameters) from ultrasound images, largely owing to a lack of training data. Mitigation usually entails image augmentation (e.g., flipping, rotating, scaling, and translating). Nevertheless, the accuracy of our task remains insufficient. Hence, we offer a U-Net fetal head measurement tool that leverages a hybrid Dice and binary cross-entropy loss to compute the similarity between actual and predicted segmented regions. Ellipse-fitted two-dimensional ultrasound images acquired from the HC18 dataset are input, and their lower feature layers are reused for efficiency. During regression, a novel region of interest pooling layer extracts elliptical feature maps, and during segmentation, feature pyramids fuse field-layer data with a new scale attention method to reduce noise. Performance is measured by Dice similarity, mean pixel accuracy, and mean intersection-over-union, giving 97.90%, 99.18%, and 97.81% scores, respectively, which match or outperform the best U-Net models.

Two Cases of Ultrasound-Guided Angiocatheter Irrigation and Drainage of the Head and Neck Abscesses (초음파 유도하 Angiocatheter를 이용한 두경부 농양의 세척 및 배농 2예)

  • Roh, Kyung-Jin;Suh, Michelle J.;Park, Sang-Chul;Kim, Hong-Jun;Kim, Bo-Mi;Shin, Hyang-Ae
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.230-233
    • /
    • 2011
  • Head and neck abscess usually requires hospitalization, intravenous antibiotic therapy, and surgical incision and drainage. Open surgical drainage may result in unsightly scars. We report two cases of a 56-year-old man with a facial abscess and a 47-year-old man with a parotid abscess. The patients were successfully treated with ultrasound-guided angiocatheter irrigation and drainage without scar. Ultrasound-guided angiocatheter irrigation and drainage can be a simple, safe and effective alternative procedure to open surgery in the management of the selected head and neck abscesses.

The Clinical Association of Thyroid Lesions in Patients with Globus Pharyngeus (인후두부 이상감을 호소하는 환자와 갑상선 병변과의 임상적 연관성)

  • Park Kyoung-Ho;Park Young-Hak;Hwang Sung-Jae;Kang Min-Gon;Park Hong-Jin;Kim Min-Sik;Cho Seung-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.10 no.2
    • /
    • pp.43-48
    • /
    • 2004
  • Background and Objectives : Globus pharyngeus is the feeling of a lump or foreign body in the throat. Otolaryngologists are often confronted with this condition, and some author reported that it represents 3 percent of all new clinic referral. The purpose of this study is to estimate the incidence of impalpable thyroid lesion in patients with globes pharyngeus and investigate possible association between globus pharyngeus and thyroid lesions. Material and Method : 146 patients with globus pharyngeus and 30 controls were prospectively examined by high resolution ultrasound. Results: Thyroid abnormalities were present in $75/146(51\%)$ patients with globus pharyngeus and in $7/30(23\%)$ controls. Of the patients with globus, 55 patients had a nodule or nodules, 11 patients had a cyst or cysts, 9 patients had diffuse abnormalities. Solitary nodule ranged from 4mm to 20mm. Conclusion : Impalpable, ultrasound detectable thyroid abnormailities are significantly more common in patients with globus pharyngeus than in controls. The thyroid abnormalities may be the cause of globus symptoms in some patients, and high resolution ultrasound is an important modality in patients presenting with globus.

  • PDF

Ultrasonographic Diagnosis of the Long Head of Biceps Tendon (이두건 장두의 초음파 진단)

  • Song, Hyun Seok
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • Lesion of long head of biceps tendon is one of the causes making an anterior shoulder pain. According to the anthropometric study of the bicipital groove the meanings of the width, depth and the medial wall angle were suggested. Confirming the images and location of the long head of biceps tendon itself would be helpful in diagnosis.

  • PDF

The Role of Ultrasound Guided Core Needle Biopsy in Thyroid Nodule (갑상선 결절에서 초음파 유도하 중심생검의 역할)

  • Ryu, Yoon-Jong;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • Fine needle aspiration cytology(FNAC) holds a main role in assessing thyroid nodules. But nonnegligible rate of thyroid cytology is reported as uncertain, indeterminate or inadequate for diagnosis. Recently, the microhistologic evaluation by core needle biopsy(CNB) under ultrasound sonographical guidance has been reported to show high accuracy for the diagnose of thyroid nodules. Aim of this review was to furnish the state of the art of this topic by summarizing previous published data about indication, diagnostic performance, and complication of CNB in thyroid lesions compared with FNAC

  • PDF

Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound (집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발)

  • Min, Jeonghwa;Kim, Juyoung;Noh, Sicheol;Choi, Heungho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.433-439
    • /
    • 2013
  • In this study, human head-mimicking phantom was developed for brain disease treatment study using focused ultrasound. Acoustic parameters of skin, skull and brain were investigated through literature investigation and adequate substitutes according to each tissue were suggested. In the case of skin phantom, construction ratio of glycerol-based TMM phantom was controlled to mimic real skin. The suitability of skull substitutes was evaluated through measurement of acoustic parameters. In the case of brain phantom, transparent egg white phantom was used to observe thermal properties of focused ultrasound. Combined human-head-mimicking phantom using each substitutes was fabricated for development of brain disease treatment protocol. Denaturation of brain phantom according to ultrasonic condition was observed for validation.

Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography (색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별)

  • Lee Kang-Dae;Lee Bong-Hee;Lee Yun-Woo;Lee Hwan-Ho;Ahn Kyong-Mo;Lee Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF