• Title/Summary/Keyword: Ultrasound examination

Search Result 314, Processing Time 0.025 seconds

A Study of the Development for Fatty Liver Quantification Diagnostic Technology from Ultrasound Images using a Simulated Fatty Liver Phantom (모사 지방간 팬텀을 활용한 초음파영상에서 지방간 정량화 진단 기술 개발을 위한 연구)

  • Yei-Ji Lim;Seung-Man Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.135-144
    • /
    • 2024
  • Ultrasonography examination has limitations in quantifying hepatic fat quantification. Therefore, this study aimed to experimentally demonstrate whether changes in signal attenuation during ultrasound imaging can be quantified using simulated hepatic phantoms to assess hepatic fat content. Additionally, we aimed to evaluate the potential of ultrasound imaging for diagnosing hepatic fatty liver by analyzing the relationship between hepatic fat content and signal intensity in ultrasound images. In this study, we developed a total of five stimulated hepatic phantoms by homogeneously mixing water and oil. We confirmed the fat content of the phantoms using magnetic resonance imaging (MRI) and ultrasound imaging, and measured signal intensity according to distance in ultrasound images to analyze the correlation and mean comparison between fat content and signal intensity. We observed that as the fat content increased, the ultrasound penetration intensity decreased, confirming the potential for quantifying hepatic fat content using ultrasound. Additionally, the analysis of the correlation between the measured fat content using MRI and the signal intensity measured in ultrasound images showed a high correlation. Statistical analysis in our study confirmed that as the fat content increased, the slope representing signal during ultrasound imaging (US-GRE) decreased. In this study, it was statistically confirmed that the US-GRE value of ultrasound images gradually decreases as the fat content increases, and it is believed that US-GRE can serve as a biomarker expressing fatty liver content.

The Results of Ultrasound Examination of the Elbow in Middle School Baseball Players (중학교 야구선수에서 시행한 주관절 초음파 검사의 결과)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Jin, Hong Ki
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • Purpose: To evaluate the ultrasonographic findings of the elbows on group screening of middle school baseball players. Materials and Methods: Ninety-three players (age: 12-15, mean 13.5 years) of four middle school baseball team were evaluated with bilateral elbow ultrasonographies in the field regardless of elbow pain. Medial and anterolateral ultrasound examination of the both elbow were performed in the field to detect any abnormalities including medial epicondylar separation or fragmentation and capitellar osteochondritis dissecans respectively. We analyzed the relationship among elbow pain, physical findings and sonographic abnormalities and the differences of sonographic abnormalities between pitchers and fielders. Results: Thirty-six of 93 (39%) players had sonographic abnormalities of elbow in dominant arm, 30 with medial epicondylar apophyseal separation or fragmentation, 2 with osteochondritis dissecans, 4 with both lesions. Twenty-nine of 37 (78%) players with elbow pain had sonographic abnormalities. On physical examination, players with medial epicondylar abnormalities had medial epicondylar tenderness (59%) and pain on valgus stress test (52%), and 5 of 6 (83%) players with osteochondritis dissecans showed flexion contracture more than $5^{\circ}$. The incidence of medial epicondylar abnormalities between pitchers and fielders was statistically not significant but osteochondritis dissecans was more prevalent in pitchers (p<0.05). Conclusion: Elbow sonography is a simple and useful screening tool in the field and also effective for early detection of medial epicondylar abnormalities or osteochondritis dissecans that could be the main causes of elbow pain in adolescent baseball players.

  • PDF

"Letter-Box" Conjunctival Flap in a Dog with Severe Corneal Edema after Phacoemulsification

  • Sunhyo Kim;Dohyoung Kwon;Kangmoon Seo;Seonmi Kang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.152-157
    • /
    • 2023
  • A two-year-old, spayed female, Bichon Frise, was referred for severe corneal edema and corneal ulcer in the left eye (OS). The cornea had gradually swelled over one week after phacoemulsification performed a month prior, and that was refractory to 5% sodium chloride eye drop instillation or temporary partial tarsorrhaphy. A complete ophthalmic examination was performed. Severe corneal edema with intrastromal bullae and moderate anterior chamber flare was found on slit-lamp biomicroscopy in the OS, which obstructed the fundus examination. Corneal thickness was measured using high-resolution ultrasound biomicroscopy. The thickness of the OS cornea was 2.74 mm. The "letter-box" conjunctival flap was planned. Dorsal and ventral superficial keratectomy followed by a hood conjunctival flap was performed. Topical and systemic antibiotics and 5% sodium chloride eye drops were prescribed. Decreased corneal thickness was observed at one week, two weeks, and two months postoperatively (1.53 mm, 1.32 mm, and 0.92 mm, respectively). There were no postoperative complications, such as ocular discomfort or recurrent corneal ulcers. The "letter-box" conjunctival flap, a type of superficial keratectomy and conjunctival advancement hood flap, effectively relieved the severe irreversible corneal edema. This could be a simple but effective surgical intervention for patients with endothelial cell damage especially after phacoemulsification.

A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province (조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 -)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • In diagnostic ultrasound, the quality of image affect to diagnose. To maintain suboptimal imaging uniformly, Quality Assurance of Ultrasound equipment should take periodically. This is article about examination the quality of image in diagnostic ultrasound to understand conditions of probes in hospitals. There is comparative study of convex and linear probes on ultrasound using tissue-mimicking phantom included simulated cysts, echogenic structures. The ultrasonic attenuation coefficient versus frequency of 0.5 dB is representative of normal liver and 0.7 dB is representative of fatty liver condition in ultrasound phantom. There are results of convex probe, 0.5 dB, vertical group, cystic masses, high contrast masses are mostly shown but 0.7 dB, mid level in vertical group, cystic masses and high contrast masses are nearly visible. In linear probe, 0.5 dB, mid level in vertical group, two or four of them are shown in cystic masses and high contrast masses but there are not visible in 11 of cases. 0.7 dB, there are mostly appear under 6 in vertical group, two or four of them show in cystic masses and high contrast masses and there are not shown in 40 of cases, besides. Linear probes in fatty liver condition of ultrasound instrument are not good in the quality of image practically. So there needs to be replace and fix of probes. Actually management of ultrasound probes is inadequate in hospitals. So if there are program of evaluation to check probes periodically in hospitals from establishment of the ultrasound equipment, there will get better image and have a suitable condition of instruments further more.

  • PDF

The Results of a Breast Cancer Screening Camp at a District Level in Rural India

  • Reddy, Neha;Ninan, Tilu;Tabar, Laszlo;Bevers, Therese
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6067-6072
    • /
    • 2012
  • Background: Breast cancer in developing countries is on the rise. There are currently no guidelines to screen women at risk in India. Since mammography in the western world is a well-accepted screening tool to prevent late presentation of breast cancer and improve mortality, it is intuitive to adopt mammography as a screening tool of choice. However, it is expensive and fraught with logistical issues in developing countries like India. Materials and Methods: Our breast cancer screening camp was done at a local district hospital in India after approval from the director and administrators. After initial training of local health care workers, a one-day camp was held. Clinical breast examination, mammograms, as well as diagnostic evaluation with ultrasound and fine needle aspiration biopsy were utilized. Results: Out of total 68 women screened only 2 women with previous history of breast cancer were diagnosed with breast cancer recurrence. None of the women in other groups were diagnosed with breast cancer despite suspicious lesions either on clinical exam, mammogram or ultrasound. Most suspicious lesions were fibroadenomas. The average cost of screening women who underwent mammography, ultrasound and fine needle aspiration was $30 dollars, whereas it was $16 in women who had simple clinical breast examination. Conclusions: Local camps act as catalysts for women to seek medical attention or discuss with local health care workers concerns of discovering new lumps or developing breast symptoms. Our camp did diagnose recurrence of breast cancer in two previously treated breast cancer patients, who were promptly referred to a regional cancer hospital. Further studies are needed in countries like India to identify the best screening tool to decrease the presentation of breast cancer in advanced stages and to reduce mortality.

Percutaneous Radiofrequency Ablation Guided by Contrast-enhanced Ultrasound in Treatment of Metastatic Hepatocellular Carcinoma after Liver Transplantation

  • Dai, Xin;Zhao, Hong-Qiang;Liu, Run-Hao;Xu, Chang-Tao;Zheng, Fang;Yu, Li-Bao;Li, Wei-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3709-3712
    • /
    • 2012
  • This study evaluated the advantages and applications of contrast-enhanced ultrasound (CEUS)-supported percutaneous radiofrequency ablation (RFA) in the treatment of metastatic hepatocellular carcinoma after liver transplantation, based on clinical details. CEUS-supported percutaneous RFA was adopted to treat 12 patients with hepatic metastatic carcinomas after liver transplantation. The diameters of the metastatic carcinomas varied from 1 cm to 5 cm, and the foci were discovered after 3 months to 12 months. Each focus was diagnosed and localised by CEUS for RFA once or twice. Curative effects were evaluated by CEUS or contrast-enhanced CT after the treatment. The re-examination results at 2 weeks post-treatment showed that the foci of 11 patients were ablated completely, whereas one patient with the largest focus required retreatment by RFA because of a partial residue. No local recurrence was found one month later in the re-examination. CEUS-supported percutaneous RFA in the treatment of hepatic metastatic carcinoma after liver transplantation has the advantages of accurate localisation, good efficacy, easy operation, and minimal invasion without any complications. Therefore, it can be recommended as the preferred therapy for hepatic metastatic carcinoma after liver transplantation.

A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule (비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치)

  • Choi Nak-Seon;Yoon Jung-Han;JaeGal Young-Jong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF

Evaluation of Waist Circumference Cut-off Values as a Marker for Fatty Liver among Japanese Workers

  • Abe, Naomi;Honda, Sumihisa;Jahng, Doosub
    • Safety and Health at Work
    • /
    • v.3 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • Objectives: Metabolic syndrome has received attention as a risk factor for cardiovascular disease, with particular importance attached to visceral fat accumulation, which is associated with lifestyle-related diseases and is strongly correlated with waist circumference. In this study, our aim is to propose waist circumference cut-off values that can be used as a marker for fatty liver based on a sample of workers receiving health checkups in Japan. Methods: This study was conducted in a total of 21,866 workers who underwent periodic health checkups between January 2007 and December 2007. The mean age of the subjects was 47.4 years for men (standard deviation [SD]: 8.0) and 44.7 years for women (SD: 6.9). Evaluation included abdominal ultrasound and measurement of waist circumference, body mass index, fasting blood glucose, triglycerides, high-density lipoprotein cholesterol, and blood pressure. Results: Based on receiver operating characteristic curve analysis, the optimal waist circumference cut-off values were shown as 85.0 cm (sensitivity 0.72, specificity 0.69) for men and 80.0 cm (sensitivity 0.75, specificity 0.78) for women. Conclusion: Abdominal ultrasound is the most efficient means of diagnosing fatty liver, but this examination seldom occurs because the test is not routinely performed at workers' health checkups. In people found to have a high risk of fatty liver, recommendations can be made for abdominal ultrasound based on the waist circumference cut-off values obtained in this study. That is, waist circumference can be used in high risk individuals as an effective marker for early detection of fatty liver.