• Title/Summary/Keyword: Ultrasound examination

Search Result 314, Processing Time 0.024 seconds

Ultrasonographic Evaluation in Patients with Inguinal Hernia (서혜부 탈장에서의 초음파 조영술)

  • Kwon, Oh-Kyoung;Jung, Jin-Hyang;Park, Jin-Young;Chang, Soo-Il
    • Advances in pediatric surgery
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2002
  • Between March 1999 and January 2000, 82 boys with the diagnosis of inguinal hernias (12 bilateral and 70 unilateral hernias), underwent Ultrasound (US) examination of both sides of the groin, a total of 164 inguinal imaging prior to surgery. The patients ages ranged from 3 days to 12 years with a mean of 32.6 months. Ninty four examinations were on the clinically symptomatic side and 70 were on the asymptomatic side. The US criteria for the diagnosis of an inguinal hernia were as follows: 1) visceral hernia, the presence of bowel loops, or omentum in the inguinal canal, 2) communicating hydrocele, the presence of fluid in the processus vaginalis, 3) widening of patent processus vaginalis at the level of internal inguinal ring. The width of patent processus vaginalis at the level of internal inguinal ring over 4 mm is considered an occult hernia. Among the 94 symptomatic groins, US findings showed 31 (33%) visceral hernias, 18 (19%) communicating hydroceles, and 38 (41%) widening of the internal inguinal ring, and 7 (7%) groins without abnormalities. In 70 asymptomatic groins, there were 4 (6%) visceral hernias, 5 (7%) communicating hydroceles, 11 (16%) widening of the internal inguinal ring, and 50 (70%) groins without abnormalities. Among the 70 asymptomatic groins there were US abnormalities in 20 (28%). One hundred and seven groins with positive US findings were surgically explored. Among 107 operated sites, the operative findings were compatible with the US diagnosis in 104, a sensitivity for US of 97.2%. In patients with US findings of widening of internal inguinal ring (>4 mm), there was patent processus vaginalis in 36 out of 38 symptomatic groins and 10 of 11 asymptomatic groins. The sensitivity of US to the operative findings in widening of internal inguinal ring was 93.8%. For visceral hernia and communicating hydrocele, the sensitivity of positive US findings was 100%. Ultrasonography for inguinal hernias appears to be a rapid, reliable, and noninvasive screening diagnostic tool with high positive specificity. Therefore, we recommend the use of US as a routine diagnostic tool in pediatric patients with inguinal hernias and hydroceles.

  • PDF

Correlation of Ultrasonographic Findings and Cytologic or Histopathologic Diagnoses of Splenic Lesions in Dogs : 124 cases (개에서 비장 병변의 초음파 소견과 세포학 및 조직병리 진단과의 상관관계 : 124 마리)

  • Kim, Jun-Young;Lee, Nam-Soon;Choi, Mi-Hyun;Kim, Wan-Hee;Youn, Hwa-Young;Hwang, Cheol-Yong;Kim, Dae-Yong;Lee, In-Hyung;Choi, Min-Cheol;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.134-140
    • /
    • 2012
  • This retrospective study was performed to describe and evaluate ultrasonographic characteristics of splenic disorders and to pursue any relationship with cytologic or histopathologic diagnoses. Medical records were reviewed for patients that had undergone both abdominal ultrasonographic procedures and ultrasound-guided fine-needle aspiration (FNA) or surgical biopsy of splenic lesions or necropsy from January 2002 to July 2011 at Seoul National University Hospital for Animals. Total 124 dogs, 76 cases with FNA and 48 cases with biopsy, were available for this investigation. The age of dogs ranged from 2 to 17 years ($mean{\pm}SD$ = $9.54{\pm}3.34$ years), with the gender distribution of 61 females (26 spayed) and 63 males (40 neutered). In breed distribution, 114 were purebred dogs and 10 were mixed breed dogs. The dogs represented 26 breeds, with 113 dogs categorized into small-sized breeds. The ultrasonographic appearances of splenic disorders could be classified into 10 types including normal appearance, depending on the distribution and echogenicity of splenic lesions as well as the increase in spleen size and diffuse parenchymal changes. Among 124 cases, 44 (35.4%) had hypoechoic nodules/masses with the highest frequency, followed by 23 (18.5%) with multiple small hypoechoic nodules. Of 124 cases, 70 (56.5%) were benign and 54 (43.5%) were malignant lesions at cytologic or histopathologic results. Each ultrasonographic appearance had variable cytologic or histopathologic diagnoses. However, diffuse heterogenicity and diffuse hypoechogenicity were significantly associated with malignancy (p < 0.05), whereas hyperechoic nodules/masses were more often associated with benignity (p < 0.05). Based on our results, it may be considered that the ultrasonographic examination for spleen could be able to provide the least information necessary for benign and malignant lesions in prioritizing differential diagnoses.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.

Fundamental Studies on the Ultrasonographic Diagnosis in Korean Native Cattle (한우에서의 초음파화상진단에 관한 연구)

  • Kim Myung-cheol;Park Kwan-ho
    • Journal of Veterinary Clinics
    • /
    • v.12 no.1
    • /
    • pp.861-876
    • /
    • 1995
  • This study was carried out to get fundamental information about the normal ultrasonogram of the liver and heart in Korean native cattle and calves. The interventricular septum, left ventricular internal diameter, left ventricular free wall thickness, aortic diameter, left atrial diameter, and right ventricular internal diameter of hear in 10 Korean native calves were determined at 4-5 right intercostal spare by use of ultrasonography. The caudal vena cava, portal vein, gallbladder, liver of 9 Korean native cattle and 10 calves were determined at 12, 11 and 10th intercostal spares by use of ultrasonography. Cursor-directed M-mode and gray-scale, B-mode ultrasonograms were obtained with electronic scanning ultrasound equipment with a 3.5 or 5.0-MHz convex transducer. The results obtained through the experiments were summarized as follows: 1. The result of ultrasonographic examination of the korean native calves' heart 1) Interventricular septum in systole and diastole was 1.23 and 0.81 cm, respectively(vc=28.84, 17.4). 2) Ventricular internal diameter in systole and diastole was 2.50 and 4.91 cm, respectively(vc=17.44, 12.73). 3) Left ventricular free was thickness in systole and diastole was 1.44 and 0.92 cm, respectively(vc=26.85, 23.54). 4) Aortic diameter was 2.69.m, .rspectevely(vc=11.29). 5) Left atrial diameter was 1.82 cm(vc=15.31). 6) Right ventricular internal diameter in systole and diastole was 1.12 and 1.9 cm, respectively(vc=33.71, 24.43). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native calves 1) Dorsal margin of caudal vena cava at the 12, 11 and 10th intercostal space was 13.5, 15.3 and 18.1 cm, respectively(p<0.01). 3) Depth of caudal vena cava at the 12, 11 and 10th intercostal space was 4.4, 4.5 and 4.6 cm, respectively. 3) Diameter of caudal vena cava at the 12, 11 and 10th intercostal space was 11.6, 1.7 and 1.6 cm, respectively. 4) Dorsal margin of portal vein at the 12, 11 and 10th intercostal space was 16.2, 18.6 and 21.4 cm, respectively(p<0.01) 5) Depth of portal vein at the 12, 11 and 10th intercostal spare was 4.5, 4.4 and 3.9 cm respectively. 6) Diameter of portal vein at the 13, 11 and 10th intercostal space was 2.1, 2.2 and 1.9 cm respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 23.6 and 23.9 cm, respectively(p<0.01), 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 7.1 and 5.9 cm, respectively(p<0.05). 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 2.4 and 2.1 cm respectively(p<0.01). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native cattle 1) Dorsal margin of caudal vena cava at the 12 and 11th intercostal space was 22.2, and 25.4 cm, respectively(p<0.01). 2) Depth of caudal vena cava at the 12 and 11th intercostal space was 103 and 11.1 cm, respectively(p<0.01). 3) Diameter of caudal vena cava at the 12 and 11th intercostal space was 3.1 and 3.0 cm, respectively. 4) Dorsal margin of portal vein at the 12 and 11th intercostal space was 29.3 and 32.9 cm, respectively(p<0.01). 5) Depth of portal vein at the 12 and 11th intercostal space was 9.6, and 9.2 cm, respectively. 6) Diameter of portal vein at the 12 and lith intercostal space was 3.4 and 3.3 cm, respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 43.1 and 45.5 cm, respectively(p<0.01). 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 10.1 and 9.4 cm, respectively. 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 4.0 and 3.7 cm, respectively. 4, Ultrasonogaphic measurments of dorsal margin, ventral margin, size and angles of the Korean native calves' liver. 1) Dorsal margin of liver at the 12, 11 and 10th intercostal space was 11.0, 9.6, and 12.4 cm, respectively(p<0.01). 2) Ventral margin of liver at the 12, 11 and 10th intercostal spate was 20, 24 and 26.1 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 9.0, 14.6 and 13.8 cm, respectively(p<0.01). 4) Angle of liver at the 12, 11 and 10th intercostal space was 40, 46 and 37, respectively(p<0.01). 5. Ultrasonographic measurmants of dorsal margin, ventral margin, size and anglses of the korean native cattle's liver 1) Dorsal margin of the liver at the 12, 11 and 10th intercostal space was 14.4, 18.2 and 26, 3 cm, respectively. 2) Ventral margin of liver at the 12, 11 and 10th intercostal space was 41.1, 46.4 and 49.3 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 26.8, 28.2 and 23.2 cm, respectively(p<0.01). 4) Angel of liverat the 15, 11 and 10 intercostal space was 41, 40.6 and 35.7, respectively(p<0.05). It was concluded that the ultrasonographic values oletermined in this study can be used as references for the diagnosis of morphologic changes in the hear and liver in korean native calves, and in the liver in korean native rattle.

  • PDF