• Title/Summary/Keyword: Ultrasound Scan

Search Result 133, Processing Time 0.028 seconds

A Case of with Transient splenic Hot Uptake on $^{99m}Tc$-Methylene Diphosphonate(MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis (간경변환자에서 복부외상후 일시적으로 관찰된 $^{99m}Tc$-MDP Bone Scan의 비장 섭취 1예)

  • Won, Jong-Hyeon;Kim, Jae-Myung;Kim, Jung-Han;Choo, Gil-Yeon;Park, Seok-Oh;Sung, Sang-Kyu;Choi, Dae-Seob;Kim, Chin-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.309-314
    • /
    • 1993
  • We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hernoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, $^{99m}Tc$-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on $^{99m}Tc$ Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  • PDF

Power Doppler Sonography for the Upper Urinary Tract Infection in Children (소아 상부요로감염의 진단을 위한 출력 도풀러 초음파조영술)

  • Choi, Jung-Youn;Cho, Jae-Ho;Park, Yong-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.179-185
    • /
    • 2007
  • Backgroud : Urinary tract infection (UTI) is common in children. The available gold standard methods for diagnosis, Tc-99m dimercaptosuccinic acid (DMSA) scan and computed tomography (CT) are invasive and expensive. This study was performed to assess the role of power Doppler ultrasound (PDU) for diagnosis of acute pyelonephritis (APN). Materials and Methods : A prospective study was conducted in 25 children with aged 2 weeks to 5 years who were hospitalized with the first episode of febrile UTI suggesting acute pyelonephritis. All children were examined in the first 3-5 days of admission by PDU and Tc-99m DMSA scan. The comparison between PDU and DMSA scan was performed on the basis of patients. Results : The sensitivity and specificity of PDU for the detection of affected kidneys were 38.1% and 50.0%, and the positive predictive value and negative predictive value were 61.9% and 50.0%, respectively. Vesicoureteral refluxes (VUR) were identified in 11 patients (44.4%) and 18 kidneys (36%). The PDU and DMSA scan showed a matching perfusion defect in 23.8% and 50.0% respectively. Conclusion : These data indicate the PDU has a relatively low sensitivity and specificity for differentiating APN from lower UTI but may be a complement tool to DMSA scan for the prediction of VUR in infants and children.

  • PDF

3D Ultrasound Panoramic Image Reconstruction using Deep Learning (딥러닝을 활용한 3차원 초음파 파노라마 영상 복원)

  • SiYeoul Lee;Seonho Kim;Dongeon Lee;ChunSu Park;MinWoo Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.255-263
    • /
    • 2023
  • Clinical ultrasound (US) is a widely used imaging modality with various clinical applications. However, capturing a large field of view often requires specialized transducers which have limitations for specific clinical scenarios. Panoramic imaging offers an alternative approach by sequentially aligning image sections acquired from freehand sweeps using a standard transducer. To reconstruct a 3D volume from these 2D sections, an external device can be employed to track the transducer's motion accurately. However, the presence of optical or electrical interferences in a clinical setting often leads to incorrect measurements from such sensors. In this paper, we propose a deep learning (DL) framework that enables the prediction of scan trajectories using only US data, eliminating the need for an external tracking device. Our approach incorporates diverse data types, including correlation volume, optical flow, B-mode images, and rawer data (IQ data). We develop a DL network capable of effectively handling these data types and introduce an attention technique to emphasize crucial local areas for precise trajectory prediction. Through extensive experimentation, we demonstrate the superiority of our proposed method over other DL-based approaches in terms of long trajectory prediction performance. Our findings highlight the potential of employing DL techniques for trajectory estimation in clinical ultrasound, offering a promising alternative for panoramic imaging.

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

Nondestructive Evaluation Technique of Painted Sandwich Control Surfaces of CN-235 using Full-field Pulse-echo Ultrasonic Propagation Imaging System (전영역 펄스-에코 초음파전파영상화 시스템의 CN-235의 도색된 샌드위치 조종면 In-situ 비파괴평가 기술)

  • Hong, Seung-Chan;Lee, Jung-Ryul;Park, Jongwoon
    • Composites Research
    • /
    • v.29 no.5
    • /
    • pp.288-292
    • /
    • 2016
  • In this paper, a novel ultrasonic propagation imaging system, called a full-field pulse-echo ultrasonic propagation imaging (FF PE UPI) system is introduced. The system nondestructively inspected targets with two-axis translation stage. The coincident laser beams for ultrasonic sensing and generation are scanned and pulse-echo mode laser ultrasounds are captured. This procedure makes it possible to generate full-field ultrasound in through-the-thickness direction as large as the scan area. Structural inspection results in the form of full-field ultrasonic wave propagation videos are introduced, which are painted sandwich control surfaces. In addition, the inspection results of FF PE UPI system are compared with conventional ultrasonic testing methods such as waterjet and portable C-scan.

Why is Hepatocellular Carcinoma Less Attributable to Viral Hepatitis in Yemen?

  • Saeed, Nadeem Mohammed;Bawazir, Amen Ahmed;Al-Zuraiqi, Masuod;Al-Negri, Fadhel;Yunus, Faisel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3663-3667
    • /
    • 2012
  • The hepatitis B virus (HBV) and the hepatitis C virus (HCV) are still public health problems in Yemen, with older individuals having much higher prevalence than younger generations. However, research on the prevalence of viral hepatitis in association with hepatocellular cancer (HCC) has not yet been undertaken in Yemen. The aim of this study was to determine the prevalence of HBV and HCV infection among HCC patients and to estimate the risk of these infections being associated with the development of HCC. A cross-sectional study was conducted on patients attending oncology outpatient in Sana'a, Yemen, through the period 2008-mid 2010 with confirmed diagnosis of HCC. A total of 88 cases were studied thoroughly with different investigations such as CT-scan, ultrasound, tumour marker, alpha-feto-protein and histopathological biopsy. A structured questionnaire was also applied and physical examination done to assess the general condition of the patients. Statistical package (SPSS version 16) was used for analysis of the data. The mean age of the cases was 61.2 years (${\pm}12.6$) with half over 60 years. There were fewer male patients (36%) compared to females and most (97%) only had basic /no formal education. Seventy nine (89%) were diagnosed as HCC cases with histopathological biopsy while the rest were diagnosed by ultrasound, CT scan, tumour marker, and alpha-feto-protein. Around one-third of the subjects were positive for HBsAg and HCV antibodies. Multivariate analysis showed infection with HCV and use of smoking was associated with HCC diagnosis. Although an association was observed between the occurrence of HCC and viral hepatitis (either HBV or HCV) and cigarette smoking, but the rate of viral infection was lower than what has been reported elsewhere.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가)

  • Lee, Dong-Hun;Yoo, Hee-Jae;Lee, Jong-Hun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.