• Title/Summary/Keyword: Ultrasound Examination

Search Result 314, Processing Time 0.022 seconds

Diagnostic Strategy of Primary Site in Metastatic Bone Tumor (전이성 골종양에서 원발병소의 진단)

  • Shin, Kyoo-Ho;Suh, Ki-Won;Jahng, Jun-Seop
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.2
    • /
    • pp.98-104
    • /
    • 1997
  • We carried out a prospective study of the effectiveness of a diagnostic strategy in thirty consecutively seen patients who had skeletal metastasis. The diagnostic strategy consisted of the recording of a medical history, physical examination, routine laboratory analysis, plain radiography of the involved bone and chest, whole-body technetium-99m-phosphonate bone scintigraphy, abdominal ultrasound, computed tomography of the chest, abdomen and pelvis, fiberbronchoscopy and fibergastroscopy. After this evaluation, a biopsy of the most accessible osseous lesion was done in twenty four patients. On the basis of the our diagnostic strategy, we were able to identify the primary site of the malignant tumor in nineteen patients(63%). The laboratory values were non-specific in all patients. The history and physical examination revealed the occult primary site of the malignant tumor in one patient(3.3%) who had carcinoma of the breast. Plain radiographs of the chest established the diagnosis of carcinoma of the lung in three patients(9.9%). Computed tomography of the chest identified an additional three primary carcinoma of the lung(9.9%). Fiberbronchoscopy identified an additional one primary carcinoma of the lung(3.3%). Abdominal ultrasound established the diagnosis in three patients(9.9%). Computed tomography of the abdomen and pelvis established the diagnosis in four patients(13.2%). Fibergastroscopy established the diagnosis in two patients(6.6%). Examination of the biopsy tissue established the diagnosis in one patient(3.3%). So we recommend to perform plain radiographs of chest, abdominal ultrasound, chest C-T, abdomino-pelvic C-T, fiber-bronchoscopy, fibergastroscopy sequentially.

  • PDF

A New Health Care Policy in Korea Part 2: Expansion of Coverage by National Health Insurance on the Abdominal Ultrasound and MRI (새로운 건강보험 보장성 강화 대책 2부: 복부 초음파 및 MRI 급여 확대)

  • Min Jae Jang;Seong Jin Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1069-1082
    • /
    • 2020
  • Coverage by National Health Insurance (NHI) was expanded in the abdominal imaging area as follows: upper abdominal ultrasound on April 1, 2018, lower abdominal ultrasound on February 1, 2019, and abdominal MRI on November 1, 2019. Many patients can benefit from the expansion of NHI coverage. Newly included diseases for NHI coverage includes liver cirrhosis, gallbladder polyps, hepatic adenoma/dysplastic nodules, pancreatic cysts, autoimmune pancreatitis and bile duct stone disease. However, the expansion of coverage made each examination more complex, including indications, follow-up strategy, the number of examination per patients, the standard images to be acquired, and the standard forms of the radiological report. Therefore, more careful consideration is mandatory when an abdominal imaging examination is prescribed and conducted.

A Study on the Illumination Environment of Ultrasound Examination Room (초음파 검사실의 조도 환경에 관한 연구)

  • Im, In-Chul;Lee, Hyo-Yeong;An, Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • The purpose of study is provide the basic data for set up proper illuminance of examination room that put purpose of an empirical study basic data about examination environment setting of the ultrasonic examination on design the examination environment of a new ultrasonic examination. As a method, to investigate the ultrasonic environment related to illumination to take a survey on the ultrasonic examination about test object to 48 parts of six units of general hospital in Busan. As a result, All Door + Curtain showed high scores in analyzing the gender, age, examination part in the case of ultrasonic examination room shielding and LED and light source control is required in the case of kind of light source. In the ultrasonic examination environment survey, the illuminance brightness is average 10 Lux which is included illuminance brightness range recommended the WHO and CEC and illuminance brightness of ultrasonic examination waiting room(ultrasonic examination waiting room, corridor) indicate average 300~800 Lux and it satisfied hospital illumination environment more than 300 Lux recommended by KSA 3011. In conclusion, Basic data suggested that improved future ultrasonic examination environment or designed new examination room on the basis of analysis result of general background and ultrasonic examination related to environment factor.

Elastography for Breast Cancer Diagnosis: a Useful Tool for Small and BI-RADS 4 Lesions

  • Liu, Xue-Jing;Zhu, Ying;Liu, Pei-Fang;Xu, Yi-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10739-10743
    • /
    • 2015
  • The present study aimed at evaluating and comparing the diagnostic performance of B-mode ultrasound (US), elastography score (ES), and strain ratio (SR) for the differentiation of breast lesions. This retrospective study enrolled 431 lesions from 417 in-hospital patients. All patients were examined with both conventional ultrasound and elastography. Two experienced radiologists reviewed ultrasound and elasticity images. The histopathologic result obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard. Pathologic examination revealed 276 malignant lesions (64%) and 155 benign lesions (36%). A cut-off point of 4.15 (area under the curve, 0.891) allowed significant differentiation of malignant and benign lesions. ROC (receiver-operating characteristic) curves showed a higher value for combination of B-mode ultrasound and elastography for the diagnosis of breast lesions. Conventional ultrasound combined elastography showed high sensitivity, specificity, and accuracy for group II lesions (10mm${\leq}20mm$). Elastography combined with conventional ultrasound show high specificity and accuracy for differentiation of benign and malignant breast lesions. Elastography is particularly important for the diagnosis of BI-RADS 4 and small breast lesions.

IOTA Simple Rules in Differentiating between Benign and Malignant Adnexal Masses by Non-expert Examiners

  • Tinnangwattana, Dangcheewan;Vichak-ururote, Linlada;Tontivuthikul, Paponrad;Charoenratana, Cholaros;Lerthiranwong, Thitikarn;Tongsong, Theera
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3835-3838
    • /
    • 2015
  • Objective: To evaluate the diagnostic performance of IOTA simple rules in predicting malignant adnexal tumors by non-expert examiners. Materials and Methods: Five obstetric/gynecologic residents, who had never performed gynecologic ultrasound examination by themselves before, were trained for IOTA simple rules by an experienced examiner. One trained resident performed ultrasound examinations including IOTA simple rules on 100 women, who were scheduled for surgery due to ovarian masses, within 24 hours of surgery. The gold standard diagnosis was based on pathological or operative findings. The five-trained residents performed IOTA simple rules on 30 patients for evaluation of inter-observer variability. Results: A total of 100 patients underwent ultrasound examination for the IOTA simple rules. Of them, IOTA simple rules could be applied in 94 (94%) masses including 71 (71.0%) benign masses and 29 (29.0%) malignant masses. The diagnostic performance of IOTA simple rules showed sensitivity of 89.3% (95%CI, 77.8%; 100.7%), specificity 83.3% (95%CI, 74.3%; 92.3%). Inter-observer variability was analyzed using Cohen's kappa coefficient. Kappa indices of the four pairs of raters are 0.713-0.884 (0.722, 0.827, 0.713, and 0.884). Conclusions: IOTA simple rules have high diagnostic performance in discriminating adnexal masses even when are applied by non-expert sonographers, though a training course may be required. Nevertheless, they should be further tested by a greater number of general practitioners before widely use.

Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography (색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별)

  • Lee Kang-Dae;Lee Bong-Hee;Lee Yun-Woo;Lee Hwan-Ho;Ahn Kyong-Mo;Lee Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF

The Prenatal and Postnatal Incidence of Congenital Anomalies of the Kidneys and Urinary Tract (CAKUT) Detected by Ultrasound

  • Choi, Hyun Ah;Lee, Dong Jun;Shin, Son Moon;Lee, Yeon Kyung;Ko, Sun Young;Park, Sung Won
    • Childhood Kidney Diseases
    • /
    • v.20 no.1
    • /
    • pp.29-32
    • /
    • 2016
  • Purpose: Congenital anomalies of the kidneys and urinary tract (CAKUT) are the most common anomalies identified in newborns. This study aims to demonstrate the prevalence of CAKUT including hydronephrosis diagnosed by antenatal and postnatal ultrasound over a five-year period. Methods: The records of births between May $1^{st}$, 2009 and April $30^{th}$, 2014 at our hospital were collected. The number of infants who underwent renal ultrasound after birth for the detection of CAKUT was counted. The incidence of each type of CAKUT such as hydronephrosis, size abnormality, horseshoe kidney, and Multicystic dysplastic kidney (MCDK) was retrospectively evaluated for antenatal screening and postnatal follow-up examination. Results: During the study period, 33,276 infants were born and 521 neonates underwent postnatal renal ultrasound. 183 cases of CAKUT were detected prenatally and 140 postnatally using ultrasonographic examinations at the following time: (i) 3-7 days postnatally in 123 newborns (87.9%), (ii) during 1-3 months in 11 newborns (7.9%), and (iii) later than 3 months in 6 newborns (4.3%). Among diagnosed CAKUT, hydronephrosis was the most common anomaly with 113 newborns diagnosed prenatally and 46 postnatally. Duplex kidney was the second most common anomaly followed by horseshoe kidney, simple cysts in the kidney and so on. Conclusion: The detection of CAKUT is an important part of the prenatal ultrasound. This study analyzed the prevalence of CAKUT detected on prenatal screening and compared the results to those detected postnatally. Prenatal ultrasound screening fulfills the needs of postnatal examinations and therefore, both antenatal and postnatal sonographic investigations are of vital importance for diagnosis of renal and urinary tract anomalies.

Ultrasound Diagnosis of Double Crush Syndrome of the Ulnar Nerve by the Anconeus Epitrochlearis and a Ganglion

  • Lee, Sang-Uk;Kim, Min-Wook;Kim, Jae Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.1
    • /
    • pp.75-77
    • /
    • 2016
  • Double compression of the ulnar nerve, including Guyon's canal syndrome associated with cubital tunnel syndrome caused by the anconeus epitrochlearis muscle, is a very rare condition. We present a case of double crush syndrome of the ulnar nerve at the wrist and elbow in a 55-year-old man, as well as a brief review of the literature. Although electrodiagnostic findings were consistent with an ulnar nerve lesion only at the elbow, ultrasonography revealed a ganglion compressing the ulnar nerve at the hypothenar area and the anconeus epitrochlearis muscle lying in the cubital tunnel. Careful physical examination and ultrasound assessment of the elbow and wrist confirmed the clinical diagnosis prior to surgery.

Prenatal diagnosis of 5p deletion syndrome: A case series report

  • Han, You Jung;Kwak, Dong Wook
    • Journal of Genetic Medicine
    • /
    • v.14 no.1
    • /
    • pp.34-37
    • /
    • 2017
  • 5p deletion syndrome, also known as Cri-du-Chat syndrome, is a chromosomal abnormality caused by a deletion in the short arm of chromosome 5. Clinical features of 5p deletion syndrome are difficult to identify prenatally by ultrasound examination, thus most cases of 5p deletion syndrome have been diagnosed postnatally. Here, we report eight cases of 5p deletion syndrome diagnosed prenatally, but were unable to find common prenatal ultrasound findings among these cases. However, we found that several cases of 5p deletion syndrome were confirmed prenatally when karyotyping was performed on the basis of abnormal findings in a prenatal ultrasound scan. Hence, it is necessary to carefully perform prenatal ultrasonography for detection of rarer chromosomal abnormalities as well as common aneuploidy.

Ultrasound-guided Distance Measurements of Vertebral Structures for Lumbar Medial Branch Block (초음파 유도하에서의 요추부 후관절 내측지 차단술을 위한 주요 척추 구조물의 거리 측정)

  • Moon, Jin Cheon;Shim, Jae Kwang;Jo, Kwang Yun;Yoon, Kyung Bong;Kim, Won Oak;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.111-115
    • /
    • 2007
  • Background: Selective diagnostic blocks of the medial branches of the dorsal primary ramus are usually performed under the guidance of fluoroscopic or computed tomography. Recently, however, ultrasound guidance has been suggested as an altemative method. In this study, the distances between the vertebral structures were measured and compared with the values measured using magnetic resonance imaging (MRI) to assess the clinical feasibility of using ultrasound-guided block in Korean patients. Methods: Five male and 15 female patients were enrolled in this study. The target point of the medial branch block in our study was the groove at the base of the superior articular process, We measured the depth from the skin to the target point at the transverse process (d-TP) and to the most superficial point of the superior articular process (d-AP). Results: The d-TP and d-AP values measured under ultrasound guidance were concordant with the values measured using MRI. Conclusions: The images of the bony landmarks obtained under ultrasound examination could be useful for ultrasound-guided lumbar medial branch block.