• 제목/요약/키워드: Ultrasound Energy

검색결과 188건 처리시간 0.028초

Ultrasound Echolocation Inspired by a Prey Detection Strategy of Big Brown Bats (박쥐의 먹이 탐지 전략을 모방한 초음파 센서의 물체 위치 추정)

  • Park, Sang-Wook;Kim, Dae-Eun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제18권3호
    • /
    • pp.161-167
    • /
    • 2012
  • It is known that big brown bats can distinguish echo of a prey at various angles. In this paper, we suggest a new object localization strategy using ultrasonic echolocation. We calculate the relative energy ratio between a high frequency component of ultrasound signal and a low frequency component of ultrasound signal for a target object. We found the measure depends on bearing angle of the object in space. We also tested energy ratio of echoed FM ultrasound signals depending on frequency, based on cross-correlation. It can determine the relative angular position of objects even though the reflected signals are congested form each object.

DEFECT DETECTION WITHIN A PIPE USING ULTRASOUND EXCITED THERMOGRAPHY

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.637-646
    • /
    • 2007
  • An UET (ultrasound excited thermography) has been used for several years for a remote non-destructive testing in the automotive and aircraft industry. It provides a thermo sonic image for a defect detection. A thermograhy is based On a propagation and a reflection of a thermal wave, which is launched from the surface into the inspected sample by an absorption of a modulated radiation. For an energy deposition to a sample, the UET uses an ultrasound excited vibration energy as an internal heat source. In this paper the applicability of the UET for a realtime defect detection is described. Measurements were performed on two kinds of pipes made from a copper and a CFRP material. In the interior of the CFRP pipe (70mm diameter), a groove (width - 6mm, depth - 2.7mm, and length - 70mm) was engraved by a milling. In the case of the copper pipe, a defect was made with a groove (width - 2mm, depth - 1mm, and length - 110 mm) by the same method. An ultrasonic vibration energy of a pulsed type is injected into the exterior side of the pipe. A hot spot, which is a small area around the defect was considerably heated up when compared to the other intact areas, was observed. A test On a damaged copper pipe produced a thermo sonic image, which was an excellent image contrast when compared to a CFRP pipe. Test on a CFRP pipe with a subsurface defect revealed a thermo sonic image at the groove position which was a relatively weak contrast.

Implementation of an Optimal Many-core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals (모바일 초음파 영상신호의 빔포밍 기법을 위한 최적의 매니코어 프로세서 구현)

  • Choi, Byong-Kook;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • 제16권8호
    • /
    • pp.119-128
    • /
    • 2011
  • This paper introduces design space exploration of many-core processors that meet high performance and low power required by the beamforming algorithm of image signals of mobile ultrasound. For the design space exploration of the many-core processor, we mapped different number of ultrasound image data to each processing element of many-core, and then determined an optimal many-core processor architecture in terms of execution time, energy efficiency and area efficiency. Experimental results indicate that PE=4096 and 1024 provide the highest energy efficiency and area efficiency, respectively. In addition, PE=4096 achieves 46x and 10x better than TI DSP C6416, which is widely used for ultrasound image devices, in terms of energy efficiency and area efficiency, respectively.

Relationship between Body Condition Score and Ultrasonographic Measurement of Subcutaneous Fat in Dairy Cows

  • Zulu, Victor Chisha;Nakao, Toshihiko;Moriyoshi, Masaharu;Nakada, Ken;Sawamukai, Yutaka;Tanaka, Yoshinobu;Zhang, Wen-Chang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권6호
    • /
    • pp.816-820
    • /
    • 2001
  • This study aimed at relating body condition score (BCS) to ultrasound measurements of subcutaneous fat over the areas most commonly used to BCS Holstein-Friesian cows, and determining the practicality of ultrasound measurement of subcutaneous fat for assessment of energy status of the cow. Twenty-eight cows were scored to the nearest quarter point on a scale of 1-5 (1=thin and 5=fat) using both visual and tactile techniques. On the same day, ultrasound measurements of subcutaneous fat were obtained at the lumbar transverse process, thurl and near the tailhead areas on both sides of the cow making six locations. Spearman's rank correlation coefficients between the six ultrasound locations ranged from 0.72-0.93 and were all significantly different from zero (p<0.01). Correlation coefficients between BCS and the mean lumbar, thurl and tailhead ultrasound measurements ranged between 0.67-0.72 and were also significantly different from zero (p<0.01). BCS was highly and significantly correlated to ultrasound measurements of subcutaneous fat. Ultrasound can be used independently or in conjunction with BCS to estimate the nutrition and energy status of cows.

Ultrasonic-assisted dissolution of U3O8 in carbonate medium

  • Chenxi Hou;Mingjian He ;Haofan Fang;Meng Zhang;Yang Gao;Caishan Jiao;Hui He
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.63-70
    • /
    • 2023
  • Ultrasound-assisted dissolution of U3O8 powder in carbonate solution was explored to determine if and how ultrasound act during the dissolution. The variation of U3O8 solid particles and uranyl complexes under ultrasound treatment and magnetic stirring was observed in carbonate media. The results show that the use of ultrasound can increase the solubility and dissolution rate of U3O8 powder than that under magnetic stirring. The crush of U3O8 particles and the reduction of the activation energy (Ea, kJ/mol) of U3O8 dissolution reaction were observed, which both play an important role in the ultrasonic-assisted dissolution of U3O8 in carbonate-peroxide solution. Meanwhile, there is no observation of the ultrasound effect on the distribution of uranyl species and hydrolysis of uranyl complexes during the ultrasound treatment in carbonate-peroxide solution. Although the generation of ·OH radicals under ultrasound (22 ± 2 kHz) was observed, the oxidation of ·OH had little effect on the dissolution of U3O8 in the carbonate-peroxide solution system.

The Study of Micro Crack Detection in Dissimilar Metal Weld Using a Variable Ultrasound Infrared Thermography (가변초음파 적외선열화상을 이용한 이종접합용접부의 미세균열 검출 연구)

  • Park, Jeong-Hak;Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제35권3호
    • /
    • pp.215-220
    • /
    • 2015
  • As a nondestructive inspection technology currently in use, infrared thermography has gradually expanded its application range to industry. The method detects only defect areas by grafting ultrasound on a technique of detecting infrared energy emitted from all objects with absolute temperature of 0 K and converting this energy into thermography for inspection. Ultrasound infrared thermography has merits including the ability to inspect a wide area in a short time without contacting the target object. This study investigated the applicability of the technique for defect detection using variable ultrasound excitation inspection methods on samples of Terfenol-D, a magnetostrictive material with a tunable natural resonant frequency.

Fast Defect Detection of PCB using Ultrasound Thermography (초음파 서모그라피를 이용한 빠른 PCB 결함 검출)

  • Cho, Jai-Wan;Jung, Hyun-Kyu;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera (적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출)

  • Kwon, DaeJu;Jung, NaRa;Kim, JaeYeol
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

Effect of Sonication on Permeability of Filter Paper (필터재 투과성 효율 증대를 위한 초음파의 활용)

  • 오세헌;황명기;김형수;김영욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.647-654
    • /
    • 2003
  • This study investigated the effect of ultrasound on the permeability of the filter paper The investigation involves laboratory experiments, and the laboratory tests were conducted under abroad range of conditions Including energy levels of ultrasonic waves, time for treatment, and temperature. The results of the study show that sonication enhances the permeability of the filter paper significantly. The degree of enhancement varies with sonication power and duration of application. The effect of sonication on permeability with temperature variation and concentration of the test specimens seems not to be significant.

  • PDF