• Title/Summary/Keyword: Ultrasound Diagnosis

Search Result 539, Processing Time 0.025 seconds

Ultrasonographic Diagnosis in the Knee (슬관절에서의 초음파적 진단)

  • Min, Kyoung-Dae
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • Ultrasound is a first line examination of the knee and useful diagnostic tool in assessing the various knee lesions. The advantages of ultrasound are that it is non-invasive, easily available at bed side, cheap, well accepted by patients, and that it has technical benefits including dynamic evaluation. Its limitations include reliability, which is largely operator dependent and its inability to evaluate deep structures. Technical guidelines of the ultrasound released by European Society of MusculoSkeletal Radiology (ESSR) and ultrasonographic findings of various knee lesions are described.

  • PDF

Design of Optimized Ultrasound Clinical Work-Flow; Usability Perspective

  • Bag, ByungEun;Yoo, SunKook;Jang, WonSeuk
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.40-42
    • /
    • 2015
  • Purpose Usability is an important factor in our life. This paper presents an approach to design the clinical work-flow for ultrasound system. And, we tried to apply this work-flow in diagnosis ultrasound system. Materials and Methods For user learnability, we follow international standard IEC 60601-1-1 and IEC 62366 which describes usability of medical instrument. User requirement are applied by 10 clinicians who are well aware of usability. We considered user environment and designed clinical work-flow into two types: general use and emergency use. The designed clinical work-flow was evaluated by 10 clinicians and results derived from the evaluation were analyzed. Results We could successfully design optimized clinical workflow of ultrasound system. Conclusion This paper suggests usability testing for optimized ultrasound clinical workflow. Using this clinical work flow, users can enhance their clinical performance and reduce operation time.

A method for ultrasound image edge enhancement by using Probabilistic edge map (초음파 진단영상 대조도 개선을 위한 확률 경계 맵을 이용한 연구)

  • Choi, Woo-hyuk;Park, Won-hwan;Park, Sungyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Ultrasonic imaging is the most widely modality among modern imaging device for medical diagnosis. Nevertheless, medical ultrasound images suffer from speckle noise and low contrast. In this paper, we propose probabilistic edge map for ultrasound image edge enhancement using automatic alien algorithm. The proposed method used applied speckle reduced ultrasound imaging for edge improvement using sequentially acquired ultrasound imaging. To evaluate the performance of method, the similarity between the reference and edge enhanced image was measured by quantity analysis. The experimental results show that the proposed method considerably improves the image quality with region edge enhancement.

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Shorter Distance Between the Nodule and Capsule has Greater Risk of Cervical Lymph Node Metastasis in Papillary Thyroid Carcinoma

  • Wang, Qiu-Cheng;Cheng, Wen;Wen, Xin;Li, Jie-Bing;Jing, Hui;Nie, Chun-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.855-860
    • /
    • 2014
  • Background: The purpose of this study was to assess the relationship between different sonographic features of papillary thyroid carcinoma (PTC) on high-frequency ultrasound and cervical lymph node metastasis (CLNM). Materials and Methods: We enrolled 548 patients who underwent initial surgery for PTC between May 2011 and December 2012 in our hospital at diagnosis. The sonographic features of 513 PTC nodules in 513 eligible patients, who had single PTC nodules in their thyroid glands, were retrospectively investigated. All patients with a suspect malignant nodule (d<0.5cm) among multiple nodules were initially diagnosed by fine-needle aspiration biopsy (FNAB) to ascertain if the suspect nodule was PTC. The final diagnosis of all the thyroid nodules and existence of CLNM were based on postoperative pathology. Patients were divided into two groups: a positive group with CLNM (224 nodules) and a negative group without CLNM (289 nodules). The following factors were investigated: gender, age, echogenicity, echotexture, size, shape, location, margin, contour, calcification morphology, distance between the nodule and pre- or post-border of the thyroid capsule, vascularity and the differences between the two groups. Results: Correlation analysis showed that shorter distances between the nodule and pre- or postborder of thyroid capsule resulted in greater risk of CLNM (Spearman correlation coefficient=-0.22, p<0.0001). The significant factors in multivariate analysis were age<45yrs, larger size (d>1cm), "wider than tall" shape, extrathyroid extension and mixed flow (internal and peripheral) (p<0.05, OR=0.406, 2.093, 0.461, 1.610, 1.322). Conclusions: Significant sonographic features of PTC nodules in preoperative high-frequency ultrasound are crucial for predicting CLNM.

The Proposal of Segmentation Algorithm for the Applying Breast Ultrasound Image to CAD (유방 초음파 영상의 CAD 적용을 위한 Segmentation 알고리즘 제안)

  • Koo, Lock-Jo;Jung, In-Sung;Bea, Jea-Ho;Choi, Sung-Wook;Park, Hee-Boong;Wang, Gi-Nam
    • IE interfaces
    • /
    • v.21 no.4
    • /
    • pp.394-402
    • /
    • 2008
  • The objective of this paper is to design segmentation algorithm for applying the breast ultrasound image to CAD(Computer Aided Diagnosis). This study is conducted after understanding limits, used algorithm and demands of CAD system by interviewing with a medical doctor and analyzing related works based on a general CAD framework that is consisted of five step-establishment of plan, analysis of needs, design, implementation and test & maintenance. Detection function of CAD is accomplished by Canny algorithm and arithmetic operations for segmentation. In addition to, long computing time is solved by extracting ROI (Region Of Interests) and applying segmentation technical methods based morphology algorithm. Overall course of study is conducted by verification of medical doctor. And validity and verification are satisfied by medical doctor's confirmation. Moreover, manual segmentation of related works, restrictions on the number of tumor and dependency of image resolution etc. was solved. This study is utilized as a support system aided doctors' subjective diagnosis even though a lot of future studies is needed for entire application of CAD system.

A Study of CBIR(Content-based Image Retrieval) Computer-aided Diagnosis System of Breast Ultrasound Images using Similarity Measures of Distance (거리 기반 유사도 측정을 통한 유방 초음파 영상의 내용 기반 검색 컴퓨터 보조 진단 시스템에 관한 연구)

  • Kim, Min-jeong;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1272-1277
    • /
    • 2017
  • To assist radiologists for the characterization of breast masses, Computer-aided Diagnosis(CADx) system has been studied. The CADx system can improve the diagnostic accuracy of radiologists by providing objective information about breast masses. Morphological and texture features were extracted from the breast ultrasound images. Based on extracted features, the CADx system retrieves masses that are similar to a query mass from a reference library using a k-nearest neighbor (k-NN) approach. Eight similarity measures of distance, Euclidean, Chebyshev(Minkowski family), Canberra, Lorentzian($F_2$ family), Wave Hedges, Motyka(Intersection family), and Cosine, Dice(Inner Product family) are evaluated by ROC(Receiver Operating Characteristic) analysis. The Inner Product family measure used with the k-NN classifier provided slightly higher performance for classification of malignant and benign masses than those with the Minkowski, $F_2$, and Intersection family measures.

Ultrasonography and Ultrasound-guided Interventions of the Shoulder

  • Moon, Sang Ho;Ko, Kwang Pyo;Baek, Seung Il;Lee, Song
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.172-193
    • /
    • 2015
  • Nowadays shoulder ultrasound is commonly used in the assessment of shoulder diseases and is as accurate as magnetic resonance imaging in the detection of several pathologies. Operator dependence is the main disadvantage of shoulder ultrasound. After adhering to a strict examination protocol, good knowledge of normal anatomy and pathologic processes and an awareness of common pitfalls, it can be used as a focused examination providing rapid, real-time diagnosis, and treatment by ultrasound-guided interventions in desired clinical situations. Also shoulder ultrasound can help the surgeon decide whether treatment will be surgical or nonsurgical. If arthroscopy is planned, sonographic findings help to counsel patients regarding surgical and functional outcomes. If a nonsurgical approach is indicated, ultrasound can be used to follow patients. This review article presents the examination techniques, the normal sonographic appearances and the main pathologic conditions found in shoulder ultrasound. And also addresses a simplified approach to scanning and ultrasound-guided intervention. Knowledge of optimal techniques, normal anatomy, dynamic maneuvers, and pathologic conditions is essential for optimal performance and interpretation of images.

Diagnosis with Ultrasound for Rib Fractures in the Golf (골프 운동중 발생한 늑골 골절의 초음파 진단)

  • Lim, Che-Joon;Youn, Te-Hyun;An, Ki-Yong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2008
  • Purpose: In most cases, the main cause of chest or back pain during playing golf is rib fractures. This kind of rib fractures can be easily overlooked in plain radiographs. The purpose of this article is to clarify the value of the ultrasound in detecting rib fractures. Materials and Methods: We compared the findings of chest-X rays (anteroposterior, left or right lateral, both oblique view) with those of the ultrasound in 56 patients between the ages of 20th & 60th who were diagnosed rib fractures. Their chief complaints were chest or back pain which developed during playing golf. The results were analyzed statistically. Results: Among 56 cases of rib fractures, 34 cases were diagnosed with initial X-rays. 51 cases were diagnosed with ultrasound. The sensitivity of radiograph and ultrasound were 60.71% & 91.07%, respectively. Dignosis was ultrasound with statical significance whereas radiography did not(p=0.0004). Conclusion: It was concluded that ultrasound is a valuable tool in the diagnosis of the rib fractures which were undetected with X-rays during playing golf.

  • PDF

A Study on the Diagnostic Usefulness of Ultrasound and Magnetic Resonance Imaging for the Diagnosis of Shoulder Rotator Cuff Tear (어깨 회전근개 파열 진단을 위한 초음파 검사와 자기공명영상 검사의 진단적 유용성 연구)

  • Chae-Won, Kang;Hyo-Young, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.961-968
    • /
    • 2022
  • Rotator cuff tears are a leading cause of shoulder pain in adults. Due to the increase in social activities, the number of patients complaining of shoulder pain is increasing, and interest in shoulder diseases is also increasing. With the development of ultrasound equipment, the sensitivity and specificity of diagnosis are high, and it is used to diagnose rotator cuff tears in musculoskeletal disease. Ultrasound is recognized as a complementary method to MRI examination in rotator cuff tears. Therefore, this study aimed to find out the diagnostic usefulness of ultrasound and MRI examinations in the diagnosis of shoulder rotator cuff tears.A retrospective analysis was performed on 262 patients who were diagnosed with final rotator cuff damage by arthroscopy after completing ultrasound and MRI examinations. Sensitivity, feature, positive predictive value, image predictive value, and touch were disassembled for the test results. In addition, the degree of clavicular tear was scored and recorded in 5 stages. Ultrasound examination was similar to MRI examination results for both full-thickness and partial tears, and there was no statistically significant difference. Partial tear test results showed higher positive predictive value and accuracy than MRI test. In conclusion, ultrasound can be fully utilized as a screening test for rotator cuff disease, and it is thought that it will be selected and used clinically according to the patient's constitution and situation.