• Title/Summary/Keyword: Ultrasound (US)

Search Result 240, Processing Time 0.027 seconds

3D Ultrasound Panoramic Image Reconstruction using Deep Learning (딥러닝을 활용한 3차원 초음파 파노라마 영상 복원)

  • SiYeoul Lee;Seonho Kim;Dongeon Lee;ChunSu Park;MinWoo Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.255-263
    • /
    • 2023
  • Clinical ultrasound (US) is a widely used imaging modality with various clinical applications. However, capturing a large field of view often requires specialized transducers which have limitations for specific clinical scenarios. Panoramic imaging offers an alternative approach by sequentially aligning image sections acquired from freehand sweeps using a standard transducer. To reconstruct a 3D volume from these 2D sections, an external device can be employed to track the transducer's motion accurately. However, the presence of optical or electrical interferences in a clinical setting often leads to incorrect measurements from such sensors. In this paper, we propose a deep learning (DL) framework that enables the prediction of scan trajectories using only US data, eliminating the need for an external tracking device. Our approach incorporates diverse data types, including correlation volume, optical flow, B-mode images, and rawer data (IQ data). We develop a DL network capable of effectively handling these data types and introduce an attention technique to emphasize crucial local areas for precise trajectory prediction. Through extensive experimentation, we demonstrate the superiority of our proposed method over other DL-based approaches in terms of long trajectory prediction performance. Our findings highlight the potential of employing DL techniques for trajectory estimation in clinical ultrasound, offering a promising alternative for panoramic imaging.

Clinical and radiological outcomes of ultrasound-guided barbotage using a spinal needle and subacromial steroid injection for calcific tendinitis of the shoulder

  • Lee, Jun Pyo;Kim, Doo Sup;Han, Jin Young;Baik, Seung Hoon;Kwak, Ji Woong;Kim, Sung Hwa
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.140-144
    • /
    • 2022
  • Background: Ultrasound (US)-guided techniques reported for the treatment of calcific tendinitis have mostly demonstrated good results. This study investigates the effect of US-guided barbotage using a spinal needle in patients with calcific tendinitis of the shoulder. Methods: Thirty-six patients with calcific tendinitis of the shoulder treated by US-guided barbotage with a spinal needle and subacromial steroid injection were included in the study. We evaluated clinical outcomes based on American Shoulder and Elbow Surgeons (ASES) score, Constant score, and visual analog scale (VAS) for pain score. Radiological outcomes were assessed by X-ray imaging at each visit. Results: Our results showed that US-guided barbotage and subacromial steroid injection produced good clinical and radiological outcomes in patients with calcific tendinitis of the shoulder. Of the 36 patients, only one required surgical treatment, while the others showed improvement without any complications. Compared to values before the procedure, calcific deposit size and VAS, ASES, and Constant scores showed significant improvement 6 weeks after the procedure. No significant correlation was found between the initial calcific deposit size and clinical outcomes at each time point. Conclusions: In patients with calcific tendinitis of the shoulder, US-guided barbotage using a spinal needle and subacromial steroid injection can yield satisfactory clinical and radiological results.

Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study

  • Son, Il Wan;Kim, Suk;Hong, Seung Baek;Lee, Nam Kyung;Jeong, Mi Ri;Han, Sung Yong;Woo, Hyun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.1
    • /
    • pp.18-23
    • /
    • 2022
  • Background: This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis. Methods: We retrospectively identified 137 patients who underwent US-guided paracentesis between July 2018 and March 2019. Among them, 82 patients underwent US-guided paracentesis with a newly developed puncture needle. The other 55 patients underwent US-guided paracentesis with a routinely used puncture needle. The periprocedural factors, complications, and repuncture rate were compared between the two groups using the Mann-Whitney U test and Fisher exact test. The repuncture-associated factors were assessed using logistic regression analysis. Results: There were no major or minor complications in either group. The rate of repuncture was significantly lower in the group using the newly developed puncture needle compared with the group using the routinely used puncture needle (p=0.01). The duration of the procedure was significantly shorter with the newly developed puncture needle compared with the routinely used puncture needle (p=0.01). In univariate analysis, the thickness of the abdominal wall (p=0.04) and the use of the newly developed puncture needle (p=0.01) were significantly associated with the rate of repuncture. In multivariate analysis, only the use of the newly developed puncture needle was significantly associated with the rate of repuncture. Conclusion: Using this novel puncture needle with a hard plastic sheath and plastic wings, the rate of repuncture and the duration of the procedure were decreased without complications of US-guided paracentesis.

Hemorrhagic Complications Following Ultrasound-Guided Breast Biopsy: A Prospective Patient-Centered Study

  • Heera Yoen;Hyun-Ah Chung;So-Min Lee;Eun-sung Kim;Woo Kyung Moon;Su Min Ha
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.157-165
    • /
    • 2024
  • Objective: We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. Materials and Methods: We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. Results: Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P = 0.027). The overall satisfaction scores did not differ between the two groups (P = 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). Conclusion: US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

Elastography for Breast Cancer Diagnosis: a Useful Tool for Small and BI-RADS 4 Lesions

  • Liu, Xue-Jing;Zhu, Ying;Liu, Pei-Fang;Xu, Yi-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10739-10743
    • /
    • 2015
  • The present study aimed at evaluating and comparing the diagnostic performance of B-mode ultrasound (US), elastography score (ES), and strain ratio (SR) for the differentiation of breast lesions. This retrospective study enrolled 431 lesions from 417 in-hospital patients. All patients were examined with both conventional ultrasound and elastography. Two experienced radiologists reviewed ultrasound and elasticity images. The histopathologic result obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard. Pathologic examination revealed 276 malignant lesions (64%) and 155 benign lesions (36%). A cut-off point of 4.15 (area under the curve, 0.891) allowed significant differentiation of malignant and benign lesions. ROC (receiver-operating characteristic) curves showed a higher value for combination of B-mode ultrasound and elastography for the diagnosis of breast lesions. Conventional ultrasound combined elastography showed high sensitivity, specificity, and accuracy for group II lesions (10mm${\leq}20mm$). Elastography combined with conventional ultrasound show high specificity and accuracy for differentiation of benign and malignant breast lesions. Elastography is particularly important for the diagnosis of BI-RADS 4 and small breast lesions.

Efficacy and Safety of Ultrasound-Guided Radiofrequency Ablation for Primary Hyperparathyroidism: A Prospective Study

  • Hui-hui Chai;Yu Zhao;Zeng Zeng;Rui-zhong Ye;Qiao-hong Hu;Hong-feng He;Jung Hwan Baek;Cheng-zhong Peng
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.555-565
    • /
    • 2022
  • Objective: To assess the efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) in patients with primary hyperparathyroidism (PHPT). Materials and Methods: This prospective study enrolled 39 participants (14 male, 25 female; mean age, 59.5 ± 15.3 [range, 18-87] years) between September 1, 2018, and January 31, 2021. All participants had parathyroid lesions causing PHPT, proven biochemically and through imaging. The imaging features of the PHPT nodules, including the shape, margin, size, composition, and location, were evaluated before treatment. Serum intact parathyroid hormone, calcium, and phosphorus levels; parathyroid nodule volume; and PHPT-related symptoms were recorded before and after treatment. We calculated the technical success, biochemical cure, and clinical cure rates for these patients. Complications were evaluated during and after the ablation. Results: Complete ablation was achieved in 38 of the 39 nodules in the 39 enrolled participants. All the patients were treated in one session. The technical success rate was 97.4% (38/39). The mean follow-up duration was 13.2 ± 4.6 (range, 6.0-24.9) months. At 6 and 12 months post-RFA, the biochemical cure rates were 82.1% (32/39) and 84.4% (27/32), respectively, and the clinical cure rates were 100% (39/39) and 96.9% (31/32), respectively. Only 2.6% (1/39) of the patients had recurrent PHPT. At 1, 3, 6, and 12 months after technically successful RFA, 44.7% (17/38), 34.3% (12/35), 15.8% (6/38), and 12.5% (4/32) of participants, respectively, had elevated eucalcemic parathyroid hormone levels. Recurrent laryngeal nerve paralysis occurred in 5.1% (2/39) of the patients, who recovered spontaneously within 1-3 months. Conclusion: US-guided RFA was effective and safe for PHPT patients. RFA may be an alternative treatment tool for patients who cannot tolerate or refuse to undergo surgery.

Radiologic Findings of Renal Inflammatory Pseudotumor: A Case Report

  • Tae Jung Kim;Seung Hyup Kim
    • Korean Journal of Radiology
    • /
    • v.1 no.4
    • /
    • pp.219-222
    • /
    • 2000
  • Renal inflammatory pseudotumor is a very rare benign condition of unknown etiology characterized by proliferative myofibroblasts, fibroblasts, histiocytes, and plasma cells. In the case we report, the lesion appeared on contrast-enhanced power Doppler US images as a well-defined hypoechoic mass with intratumoral vascularity, and on CT as a low-attenuated mass. Differentiation from malignant renal neoplasms was not possible.

  • PDF

Removal of PCBs in Aqueous Phase in Ultraviolet (UV), Ultrasonic (US), and UV/US Processes (자외선 및 초음파 공정에 의한 수용액 상의 PCBs 분해)

  • Lee, Dukyoung;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.4
    • /
    • pp.1-7
    • /
    • 2021
  • The removal of PCBs (Polychlorinated biphenyls) in aqueous phase was investigated in the ultraviolet (UV) process, ultrasonics (US) process and ultraviolet/ultrasonic (UV/US) process using PCB No.7 and Aroclor 1260. For PCB No.7 relatively high removal efficiency over 90% was obtained during 20 min in the UV process and UV/US process. On the other hand, lower removal efficiency of 50 - 70% was achieved for it consisted of individual congeners of PCBs containing 3~8 of chlorine atom. It was found that the dechlorination reaction (the photolytic cleavage of C-Cl bond) was considered as a main removal mechanism in the UV process while PCBs were removed by cavitation-induced radical reaction in the US process. No significant dechlorination occurred in the US process. Consequently, it was suggested that the UV process or UV/US process was applicable for the removal of PCBs in aqueous phase in terms of the removal efficiency and operation time. In addition, the application of saturating gas such as Ar and Air could be considered to control redox condition and enhance the severity of acoustic cavitation for the removal of PCBs.

Useful Ultrasound Findings of Pediatric Patients with Equivocal Results of Appendicitis: Analysis Based on a Structured Report Form (애매한 초음파 결과를 보인 소아 환자에서 충수돌기염을 감별하는데 유용한 초음파 소견: 구조화 판독문에 기초한 분석)

  • Jiyoung Choi;Hyuk Jung Kim;Suk Ki Jang;Hyun Jin Kim;Jae Woo Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.182-193
    • /
    • 2021
  • Purpose To identify the features that can be used for differentiating appendicitis from non-appendicitis in pediatric patients with equivocal ultrasound (US) results. Materials and Methods A total of 53 pediatric patients (≤ 18 years old) with equivocal results on US examination for suspected appendicitis between November 2012 and October 2017 were included. US evaluation was conducted based on information retrieved from a predefined structured report form. Then, the likelihood of appendicitis was prospectively classified into five categories. The equivocal results were considered as grade 3 (indeterminate) and grade 4 (probably appendicitis). Results Of the 53 patients, 25 (47.2%) and 28 (52.8%) were classified into grade 3 and 4 groups, respectively. Among the individual US findings, increased vascularity of the appendiceal wall and peri-appendiceal fat infiltration were independent findings associated with the diagnosis of appendicitis (p = 0.005, p = 0.045, respectively) in the multivariate logistic regression analysis and showed the highest diagnostic accuracy (69.8% and 62.3%, respectively). Conclusion Increased vascularity within the appendiceal wall and peri-appendiceal fat infiltration were significant predictors of appendicitis in patients with equivocal US findings.