• 제목/요약/키워드: Ultrasound (US)

검색결과 244건 처리시간 0.029초

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • 한국전문물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

정중신경 손상에서 초음파 유도 하 신경주위 포도당 용액 주사치료의 효과 (Effect of Ultrasound-Guided Perineural Injection with Dextrose for Direct Traumatic Injury of Median Nerve)

  • 정유상;박혜린;박중현;박희재;조한얼
    • Clinical Pain
    • /
    • 제20권2호
    • /
    • pp.127-130
    • /
    • 2021
  • Ultrasound (US)-guided hydrodissection (HD) is a widely applied therapeutic method to release the entrapped peripheral nerve. However, this therapy has only been studied for the nerve entrapments such as carpal tunnel syndrome, and there are no reports of its effect on direct nerve injuries with incomplete axonal damage. Here, we report a case of direct traumatic injury of a median nerve with incomplete axonal injury in a 28-year-old man. He presented hypoesthesia and weakness along with the median nerve territory of the left hand after a laceration wound of the wrist. The patient underwent a surgical procedure, but did not experience prominent improvement for the next six months. Symptoms improved after we performed the US-guided HD with dextrose. We propose this procedure as one of the new treatment methods for direct axonal injury of nerves including the median nerve.

The Role of Core Needle Biopsy for the Evaluation of Thyroid Nodules with Suspicious Ultrasound Features

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.158-165
    • /
    • 2019
  • Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features. Materials and Methods: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis. Results: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results. Conclusion: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.

직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구 (In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma)

  • 이황규;지금난;홍수진;고재향
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.133-143
    • /
    • 2013
  • 목적 : 직결장암 조직의 자기공명영상과 고주파 초음파검사를 시행한 후 종양의 탐지와 침윤 깊이에 대해 각각의 영상 소견과 병리 소견을 비교하여 진단적 정확도를 두 영상 기기 간 비교하고, 자기공명영상의 경우 종양의 침윤 깊이를 주변 정상 조직과 가장 명확히 보여주는 펄스 연쇄 (pulse sequence)에 대해 알아보았다. 대상 및 방법 : 직결장암으로 절제술을 시행한 45명의 환자에서 얻은 45예의 제거된 종양 조직을 수조에 넣고 생리 식염수에 담가서 고주파수 (5-17 MHz)의 선형 탐촉자를 이용하여 초음파영상을 얻었으며 8-channel 두경부 코일에 넣어 자기공명영상을 얻었다. 이 연구에 대하여 기관감사위원회의 공지에 입각한 동의는 면제되었다. 자기공명영상은 정- 및 탈위상 경사에코 T1 강조영상, 급속스핀에코 T2 강조영상 및 이의 지방억제 영상, fast imaging employing steady-state acquisition (FIESTA)와 이의 지방억제영상, 확산강조영상 등 일곱 가지 펄스 연쇄를 시행하였다. 각 조직의 자기공명영상과 초음파영상 소견을 각각 독립적으로 종양의 탐지와 침윤 깊이에 대하여 두 명의 영상의학과 의사가 합의 하에 평가하였고 각각의 영상 소견을 병리 조직 소견과 비교하여 두 영상 기기 간 진단적 정확도를 비교하였다. 자기공명영상의 일곱 가지 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확히 보여주는 펄스 연쇄에 대해 알아보았다. 결과 : 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 있어 자기공명영상과 초음파의 진단적 정확도는 각각 91.1%와 86.7%로 높게 나타났다. 조기 직결장암의 경우 초음파 검사의 정확도는 87.5%, 자기공명영상 검사의 정확도는 75.0%로 나왔다. 두 영상 기기 간에 통계적으로 유의한 차이는 없었다 (p > 0.05). MR의 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확하게 보여주는 영상은 직결장암 및 조기 직결장암 모두 급속 스핀에코 T2 강조영상이었다. 결론 : 자기공명영상과 초음파 검사는 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 높은 진단적 정확도를 가지고 있으며, 자기공명영상의 급속스핀에코 T2 강조영상이 직결장암 조직의 종양 침윤 깊이를 평가하는데 가장 우수하였다.

초음파 보조하에 시행한 치골상부 방광천자의 유용성 (Suprapubic Bladder Aspiration Assisted by Ultrasound)

  • 이정원;박소은;조수진;유은선;김혜순;이승주
    • Childhood Kidney Diseases
    • /
    • 제6권1호
    • /
    • pp.68-74
    • /
    • 2002
  • 목 적 : 요로감염의 진단에는 오염되지 않은 소변의 배양검사가 필수적이다. 소변가리기 훈련이 안된 영유아에서 치골상부 방광천자는 가장 확실한 채뇨법이지만 침습적이어서 보편화되지 못하였으나 최근 초음파 감시하에 시행하여 성공률을 높이고 합병증의 빈도를 줄일수 있다고 하였다. 따라서 저자들은 응급실내에서 시행된 이동식 초음파 보조하 치골상부 방광천자의 유용성을 조사하기 위하여 전향적인 연구를 시행하였다. 대상 및 방법 : 2001년 5월부터 2001년 8월까지 이대 목동병원 응급실에 내원한 환아중 요로감염이 의심되어 방광천자뇨가 필요한 영유아들을 대상으로 무작위로 초음파 보조하에 방광천자를 시행한 초음파군(32명)과 초음파 보조 없이 맹목적으로 방광천자를 시행한 대조군(28명)으로 구분하였다. 초음파군은 응급실의 이동식 초음파기(Sonoace 8800)를 사용하였고 5MHz 탐촉기로 방광의 전후직경, 좌우직경, 깊이를 측정후 천자하였으며 대조군은 치골상부에서 방광이 촉지되었을 때 천자하였다. 두 군에서 방광천자의 성공률, 시도횟수, 채취량을 비교하였고 초음파군에서 방광치수와 성공률과의 관련성을 조사하였다. 통계는 SAS system을 이용한 chi 검정과 Wilcoxon rank sum을 사용하였다. 결 과 : 초음파군의 총성공률은 $100\%$(32/32)로 대조군의 $85.7\%$(24/28)에 비하여 유의하게 높았다(P<0.05). 천자된 소변량은 초음파군이 $7.4{\pm}3.7\;mL$로 대조군의 $4.5{\pm}3.4\;mL$에 비하여 유의하게 많았다(P<0.05). 초음파군에서 첫번째 시도로 성공한 경우(n=23)의 방광 전후직경은 $2.1{\pm}0.7\;cm$, 좌우직경은 $3.1{\pm}0.6\;cm$, 깊이는 $4.2{\pm}1.0\;cm$, 방광용적은 $15.2{\pm}10.4\;mL$로 실패한 경우(n=9)의 전후직경 $1.7{\pm}0.3\;cm$, 좌우직경 $1.8{\pm}0.7\;cm$, 깊이 $2.4{\pm}0.6\;cm$, 방광용적 $3.9{\pm}2.5\;mL$에 비하여 각각 유의한 차이가 있었다(P<0.05). 방광용적은 깊이(r=0.91), 전후직경(r=0.78), 좌우직경(r=0.72)순으로 유의한 상관관계가 있었으며(P<0.05) 전후직경 3 cm이상, 좌우직경 4 cm이상, 깊이 4 cm 이상, 방광용적 5 mL 이상에서 성공률이 $100\%$이였다. 결 론 :요로감염이 의심되는 영유아에서 초음파 보조하 치골상부 방광천자는 성공률이 높고 안전한 채뇨 방법으로 보편화 되어야 한다고 생각한다.

  • PDF

초음파가 흰쥐의 좌골신경 압좌손상 후 척수내 Neural Cell Adhesion Molecules의 발현에 미치는 영향 (The Effect of Ultrasound Irradiation on the Neural Cell Adhesion Molecules(NCAM) Expression in Rat Spinal Cord after the Sciatic Nerve Crush Injury)

  • 김현애;한종만
    • The Journal of Korean Physical Therapy
    • /
    • 제19권2호
    • /
    • pp.41-55
    • /
    • 2007
  • Purpose: This study aimed to compare the effect on nerve regeneration of ultrasound irradiation in rats with peripheral nerve injury. Methods: To investigate alterations of the NCAM immunoreactivity in non-crushed part and crushed part of the spinal cord, the unilateral sciatic nerve of the rats were crushed. The expression of NCAM was used as the marked of peripheral nerve regeneration, and also plays an important role in developing nerve system. Experimental animals were sacrificed by perfusion fixation at post-injury 1, 3, 7, 14 days after ultrasound irradiation. The pulsed US was applied at a frequency of 1MHz and a spatial average-temporal average Intensity of 0.5W/of (20% pulse ratio) for 1 mins. The Luxol fast blue-cresyl violet stain were also done to observe the morphological changes. Results: Alteration of NCAM immunoreactivity in the crushed part and the non-crushed part of lower lumbar spinal cord were observed. NCAM-immunoreactivity cells were some increased in the dorsal horn lamina I, III and cell ventral horn at 1 day after unilateral sciatic nerve injury. However, there was not significant difference in the relationship between crushed part and non-crushed part. NCAM-inmmunoreactivity was remarkably increased at 3 days after unilateral sciatic nerve injuryin the gray matter and white matter. NCAM-immunoreactivity was increased in the ventral horn and post horn of experimental crushed part. Also, NCAM-immunoreactivity in large motor neurons in ventral horns lamina VIII, IX were increased at 7 days after unilateral sciatic nerve injury. At 14 days after sciatic nerve crushed injury, there was no significant difference. All group were decreased for 14 days. In the time course of NCAM expression, all groups showed a significant difference at 3day groups(p<0.05). Whereas, CC group was noted a significant difference between 3day and 7 day group respectively. In NCAM expression, there were significantly increased in all group. In the relationship between CNC group and ENC group, significant difference was detected among 3, 7, 14 day group(p<0.05). The difference between CC group and ENC group were noted in all groups(p<0.05). Conclusion: It is consequently suggested that the effects of the ultrasound irradiation may increase the NCAM immunoreactive neurons and glial cell in the spinal cord after unilateral sciatic nerve crushed injury. Therefore, the increased NCAM immunoreactivity in the spinal cord may reflect the neuronal damage and healing process induced by a ultrasound irradiation after peripheral nerve injury in rat.

  • PDF

Quantitative Ultrasound Radiofrequency Data Analysis for the Assessment of Hepatic Steatosis in Nonalcoholic Fatty Liver Disease Using Magnetic Resonance Imaging Proton Density Fat Fraction as the Reference Standard

  • Sun Kyung Jeon;Jeong Min Lee;Ijin Joo;Sae-Jin Park
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1077-1086
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of quantitative ultrasound (US) parameters for the assessment of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD) using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as the reference standard. Materials and Methods: In this single-center prospective study, 120 patients with clinically suspected NAFLD were enrolled between March 2019 and January 2020. The participants underwent US examination for radiofrequency (RF) data acquisition and chemical shift-encoded liver MRI for PDFF measurement. Using the RF data analysis, the attenuation coefficient (AC) based on tissue attenuation imaging (TAI) (AC-TAI) and scatter-distribution coefficient (SC) based on tissue scatter-distribution imaging (TSI) (SC-TSI) were measured. The correlations between the quantitative US parameters (AC and SC) and MRI-PDFF were evaluated using Pearson correlation coefficients. The diagnostic performance of AC-TAI and SC-TSI for detecting hepatic fat contents of ≥ 5% (MRI-PDFF ≥ 5%) and ≥ 10% (MRI-PDFF ≥ 10%) were assessed using receiver operating characteristic (ROC) analysis. The significant clinical or imaging factors associated with AC and SC were analyzed using linear regression analysis. Results: The participants were classified based on MRI-PDFF: < 5% (n = 38), 5-10% (n = 23), and ≥ 10% (n = 59). AC-TAI and SC-TSI were significantly correlated with MRI-PDFF (r = 0.659 and 0.727, p < 0.001 for both). For detecting hepatic fat contents of ≥ 5% and ≥ 10%, the areas under the ROC curves of AC-TAI were 0.861 (95% confidence interval [CI]: 0.786-0.918) and 0.835 (95% CI: 0.757-0.897), and those of SC-TSI were 0.964 (95% CI: 0.913-0.989) and 0.935 (95% CI: 0.875-0.972), respectively. Multivariable linear regression analysis showed that MRI-PDFF was an independent determinant of AC-TAI and SC-TSI. Conclusion: AC-TAI and SC-TSI derived from quantitative US RF data analysis yielded a good correlation with MRI-PDFF and provided good performance for detecting hepatic steatosis and assessing its severity in NAFLD.

대퇴동맥을 통한 시술 후 발생한 가성동맥류의 초음파 유도하 경피적 트롬빈 주입 치료 (Ultrasound-Guided Percutaneous Thrombin Injection of Femoral Artery Pseudoaneurysms Caused by Vascular Access)

  • 채승윤;박찬;김재규;김형욱;이병찬
    • 대한영상의학회지
    • /
    • 제82권3호
    • /
    • pp.589-599
    • /
    • 2021
  • 목적 대퇴동맥을 통한 시술 후 발생한 의인성 가성동맥류에 대한 초음파 유도하 경피적 트롬빈 주입 치료의 성공률과 합병증 발생률, 치료의 실패에 관련된 요인 등을 분석해 보고자 한다. 대상과 방법 2009년 3월부터 2019년 6월까지 대퇴동맥에 발생한 의인성 가성동맥류에 대하여 영상의학과에서 초음파 유도하 경피적 트롬빈 주입 치료를 받은 30명의 환자들을 후향적으로 분석하였다. 대퇴동맥의 가성동맥류는 초음파 또는 전산화단층촬영을 사용하여 진단하였으며, 환자와 병변의 특성에 대하여 분석하였다. 결과 환자들의 평균 나이는 67.8세였으며, 가성동맥류의 평균 직경은 20.88 mm (5~40 mm)였다. 첫 치료에서 20명의 환자에서 완전한 혈전형성을 보였으며(66.6%), 10명의 환자에서 부분적 혈전형성을 보였다(33.3%). 혈소판 수가 낮은 환자(< 130 k/µL)에서 부분적 혈전형성의 가능성이 유의하게 높았다. 모든 환자에서 시술 관련 합병증은 보이지 않았다. 결론 대퇴동맥의 의인성 가성동맥류에 대한 초음파 유도하 트롬빈 주입 치료는 안전하고 효과적인 우선적 치료 방법이다.

Delayed Cancer Diagnosis in Thyroid Nodules Initially Treated as Benign With Radiofrequency Ablation: Ultrasound Characteristics and Predictors for Cancer

  • Myoung Kyoung Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim
    • Korean Journal of Radiology
    • /
    • 제24권9호
    • /
    • pp.903-911
    • /
    • 2023
  • Objective: Regrowth after radiofrequency ablation (RFA) of symptomatic large thyroid nodules, initially treated as benign, sometimes turns out to be malignancies. This study aimed to assess the ultrasound (US) characteristics of thyroid nodules initially treated as benign with RFA and later diagnosed as cancers, predictive factors for cancers masquerading as benign, and methods to avoid RFA in these cancers. Materials and Methods: We reviewed the medical records of 134 consecutive patients with 148 nodules who underwent RFA between February 2008 and November 2016 for the debulking of symptomatic thyroid nodules diagnosed as benign using US-guided biopsy. We investigated the pre-RFA characteristics of the thyroid nodules, changes at follow-up after RFA, and the final surgical pathology. Results: Nodule regrowth after RFA was observed in 36 (24.3%) of the 148 benign nodules. Twenty-two of the 36 nodules were surgically removed, and malignancies were confirmed in seven (19.4% of 36). Of the 22 nodules removed surgically, pre-RFA median volume (range) was significantly larger for malignant nodules than for benign nodules: 22.4 (13.9-84.5) vs. 13.4 (7.3-16.8) mL (P = 0.04). There was no significant difference in the regrowth interval between benign and malignant nodules (P = 0.49). The median volume reduction rate (range) at 12 months was significantly lower for malignant nodules than for benign nodules (51.4% [0-57.8] vs. 83.8% [47.9-89.6]) (P = 0.01). The pre-RFA benignity of all seven malignant nodules was confirmed using two US-guided fine-needle aspirations (FNAs), except for one nodule, which was confirmed using US-guided core-needle biopsy (CNB). Regrown malignant nodules were diagnosed as suspicious follicular neoplasms by CNB. Histological examination of the malignant nodules revealed follicular thyroid carcinomas, except for one follicular variant, a papillary thyroid carcinoma. Conclusion: Symptomatic large benign thyroid nodules showing regrowth or suboptimal reduction after RFA may have malignant potential. The confirmation of these nodules is better with CNB than with FNA.

Ten-Year Outcomes of Radiofrequency Ablation for Locally Recurrent Papillary Thyroid Cancer

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제25권9호
    • /
    • pp.851-858
    • /
    • 2024
  • Objective: This study investigates the long-term efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) for treating locally recurrent papillary thyroid cancer (PTC). Materials and Methods: We retrospectively analyzed 39 consecutive patients with 61 locally recurrent PTCs (14 males, 25 females; mean ± standard deviation age, 52.8 ± 16.7 years; range 21-92 years) who underwent US-guided RFA with curative intent between September 2008 and April 2012. A subgroup of 24 patients with 37 recurrent PTCs who had a follow-up of at least 10 years were analyzed separately. All patients were followed for changes in lesion size on US and thyroglobulin (Tg) levels at 1, 3, 6, and 12 months after RFA, with follow-up every 6-12 months thereafter. Any complications were documented during the follow-up period. Recurrence-free survival (RFS) rates were assessed using Kaplan-Meier estimates. Long-term outcomes were evaluated in patients with follow-up of at least 10 years. Results: The follow-up period ranged from 7 to 180 months (median 133 months). The RFS rates for the 39 patients at 3, 5, and 10 years were 86.8%, 75.5%, and 60.6%, respectively. Among the 24 patients with 37 recurrent PTCs followed for more than 10 years, the volume reduction rate was 99.9% (range 96%-100%), and the complete tumor disappearance rate was 91.9%. The mean serum Tg level also decreased significantly, from 2.66 ± 86.5 mIU/L before ablation to 0.43 ± 0.73 mIU/L (P < 0.001) at the final follow-up. In 14 (58.3%) of the 24 patients, Tg levels were undetectable (below 0.08 mIU/L) at the last follow-up. No life-threatening or delayed complications were observed during the 10-year follow-up period. Conclusion: The high RFS throughout the follow-up period, with efficacy and safety lasting beyond 10 years, supports US-guided RFA as a valuable option for local control of recurrent PTCs.