• Title/Summary/Keyword: Ultrasonography imaging

Search Result 526, Processing Time 0.027 seconds

Leiomyosarcoma of Urinary Bladder in a Yorkshire Terrier Dog

  • Mok, Jinsu;Park, Junghyun;An, Soyon;Kim, Ahreum;Han, Changhee;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.91-95
    • /
    • 2020
  • A 13-year-old, intact male, Yorkshire terrier dog with oliguria and hematuria was presented to the Small Animal Clinic at the Gyeongsang National University animal medical center. There were no remarkable findings on serum chemistry values and complete blood counts. Abdominal radiographs revealed mild elevation of the descending colon at the pelvic level. On the excretory urographic images, a large filling defect was identified in urinary bladder with narrow urinary bladder wall contact and there were no remarkable findings in kidneys and ureters. The abdominal ultrasonography revealed that an irregularly marginated, heterogeneous mass in urinary bladder, central cavitary lesion and mild vascular flow were also observed. Computed tomography showed a heterogeneously attenuated mass within urinary bladder. The mass was surgically excised, and leiomyosarcoma was confirmed by histopathological examination. The patient was followed up for two months and there were no complications. This case is of interest because of the unusual findings of leiomyosarcoma of urinary bladder in a small breed dog.

A Case Report of Juvenile Hypertrophy of the Breast in a 15-Year-Old Girl: Presented with Asymmetric Breast Enlargement and a Focal Mass-like Lesion

  • Park, Jae Yeon;Kim, Sung Hun;Jung, Na Young;Kang, Bong Joo;Lee, Ah Won;Jin, Min-Sun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.175-178
    • /
    • 2019
  • Juvenile hypertrophy of the breast is a rare condition, leading to hyperplastic breast anomalies in adolescents. Here, we report a case involving a 15-year-old girl, presented with asymmetric enlargement of the left breast. Pronounced parenchymal thickening was found on initial ultrasonography (US). MRI and second-look US revealed a focal mass-like lesion on the left mid-lateral breast, confirmed as juvenile hypertrophy of the breast on pathology.

Angiosarcoma of the Breast and Spleen: A Case Report with Imaging and Pathologic Findings (유방 및 비장의 혈관육종: 영상 소견 및 병리 소견을 포함한 증례 보고)

  • Jieun Kim;Hyun Kyung Jung;Woogyeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1310-1314
    • /
    • 2021
  • Angiosarcoma of the breast is a rare malignant sarcoma of endovascular origin that presents with various radiological findings. We encountered a case of angiosarcoma of the breast presenting as an irregular indistinct hyperechoic mass on ultrasonography, with a large single angiosarcoma of the spleen in a previously healthy 36-year-old female. Herein, we report the imaging and pathologic findings and review the literature.

Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques

  • Junghoan Park;Jeong Min Lee;Gunwoo Lee;Sun Kyung Jeon;Ijin Joo
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.13-29
    • /
    • 2022
  • Nonalcoholic fatty liver disease, characterized by excessive accumulation of fat in the liver, is the most common chronic liver disease worldwide. The current standard for the detection of hepatic steatosis is liver biopsy; however, it is limited by invasiveness and sampling errors. Accordingly, MR spectroscopy and proton density fat fraction obtained with MRI have been accepted as non-invasive modalities for quantifying hepatic steatosis. Recently, various quantitative ultrasonography techniques have been developed and validated for the quantification of hepatic steatosis. These techniques measure various acoustic parameters, including attenuation coefficient, backscatter coefficient and speckle statistics, speed of sound, and shear wave elastography metrics. In this article, we introduce several representative quantitative ultrasonography techniques and their diagnostic value for the detection of hepatic steatosis.

Imaging Features of Mucinous Breast Carcinoma (점액암의 영상소견)

  • Han, Hye-Jung;Kim, Sung-Hun;Cha, Eun-Suk;Kim, Hyun-Sook;Kang, Bong-Joo;Choi, Jae-Jung;Lee, Jee-Hye;Lee, Ah-Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.21-30
    • /
    • 2010
  • Purpose : To examine the imaging findings of mucinous breast carcinoma and to evaluate the difference in these findings based on the histopathologic grade. Materials and Methods : We retrospectively analyzed the imaging features according to BI-RADS in 29 patients with surgically proven mucinous carcinoma. The histopathologic grade was classified as well-differentiated, moderately-differentiated and poorly-differentiated. Based on these criteria, the differences in imaging findings were statistically analyzed. Results : Mammography was available in 20 cases, which contained 17 mass lesions (85%) and 3 cases of normal findings. On ultrasonography (27 cases), mucinous carcinoma was observed as a mass with an oval shape (59.3%), a microlobulated margin (55.6%) or an inhomogeneous isoechogenicity (74.1%). On MRI (21 cases), mucinous carcinoma was commonly observed to have a lobular shape (76%), smooth margin (86%) or heterogeneous contrast-enhancement (61.9%). On the kinetic curve, there was a delayed wash-out pattern (52.3%). There were no significant differences in the imaging findings for each histopathologic grade except that a welldifferentiated tumor had an abrupt interface. Conclusion : A well-differentiated mucinous carcinoma tended to have an abrupt interface on ultrasonography, as compared with the moderately-differentiated one. Mucinous carcinoma showed a heterogeneous enhancement and a delayed washout kinetic curve pattern on dynamic MRI.

Hepatic Angiomyolipoma: Contrast Patterns with SonoVue-enhanced Real-time Gray-scale Ultrasonography

  • Wei, Rui-Xue;Wang, Wen-Ping;Ding, Hong;Huang, Bei-Jian;Li, Chao-Lun;Fan, Pei-Li;Hou, Jun;He, Nian-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.2
    • /
    • pp.493-497
    • /
    • 2012
  • This study was conducted to retrospectively evaluate the pattern of contrast enhancement with SonoVue on gray-scale ultrasonography of hepatic angiomyolipoma (HAML). Imaging features of 33 pathologically proven HAML lesions in 33 patients who underwent baseline ultrasound and contrast-enhanced ultrasonography (CEUS) were assessed retrospectively. All lesions were enhanced in the arterial phase and showed whole-tumor filling in. Thirty-two of 33 (97%) lesions showed early positive enhancement in the arterial phase. Twenty-three of these exhibited isoechoic or hyperechoic features in the portal phase. HAML demonstrate characteristic manifestations with SonoVue-enhanced real-time gray-scale ultrasonography.

Ultrasonographic and magnetic resonance images of a gluteus maximus tear

  • Kim, Jong Bum;Lee, Wonho;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.2
    • /
    • pp.157-159
    • /
    • 2021
  • The diagnosis of a gluteal muscle tear or strain is based on clinical findings. However, for an accurate diagnosis, imaging examinations are also needed. Herein, we describe the case of a patient with a gluteus maximus muscle tear confirmed by ultrasonography (US) and magnetic resonance imaging (MRI). A 58-year-old woman complained of dull pain in the left lateral gluteal region that she had been experiencing for 8 days. In the axial US image, retraction of the left gluteus maximus muscle was noted around its insertion site in the iliotibial band. On an MRI, a partial tear in the left gluteus maximus was observed at its insertion site in the left iliotibial band. In addition, fluid infiltration due to edema and hemorrhage was observed. A partial left gluteal muscle tear was diagnosed. The patient was treated with physical therapy at the involved region and oral analgesics. She reported relief from the pain after 1 month of treatment. Based on this experience, we recommend US or MRI for accurate diagnosis of muscle tear or strain.

The Effect of Five Different Trunk Stabilization Exercise on Thickness of Abdominal Muscle Using an Ultrasonography Imaging in Normal People (정상인에서 5가지 체간 안정화 운동자세가 초음파 영상을 이용한 복부근 두께에 미치는 영향)

  • Kang, Jung-Hyun;Shim, Jae-Hun;Chon, Seung-Chul
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • The aim of this study is to compare measurements of abdominal muscle thickness using ultrasonography imaging (USI) to those using a special transducer head device, during five different trunk stabilization exercises, ultimately to determine which exercise led to the greatest muscle thickness. Thirty eight healthy subjects participated in this cross-sectional study. The five types of trunk stabilization - i.e., a sit-up on the supine, an upper and lower extremity raise with quadruped on the prone, a leg raise in sitting on the ball, trunk rolling on the ball, and balance using sling on the prone position - were each performed with an abdominal draw. The thickness of the abdominal muscle - including the transverse abdominal (TrA), internal oblique (IO), and external oblique (EO) - was measured by USI with a special transducer head device, at rest and then at contraction in each position. Data were analyzed using one-way repeated ANOVA with the level of significance set at ${\alpha}$=.05. The results were as follows: 1) the TrA thickness was statistically significant (p<.05), whereas the IO and EO thicknesses were not (p>.05); 2) among the five types of trunk stabilization, TrA thickness significantly increased with the balance using a sling in the prone position, (p<.05), whereas no significant difference was noted for the four types of trunk stabilization (p>.05); 3) reliability data showed that there was a high degree of consistency among the measurements taken using the special transducer head device (ICC=.92). In conclusion, the balance using a sling in the prone position was more effective than any of the four other types of trunk stabilization in increasing TrA thickness in healthy subjects.