• Title/Summary/Keyword: Ultrasonographic Image

Search Result 41, Processing Time 0.025 seconds

Serial ultrasonographic appearance of postpartum uterine involution in Korea Jin-do dogs (진도개에서 분만후 자궁수복의 연속적 초음파상)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun;Kim, Ki-won;Kang, Hyun-gu;Shin, Chang-rok;Park, In-chul
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.653-664
    • /
    • 1999
  • This study was undertaken to determine the normal appearance of the postpartum uterine involution. Postpartum changes in uterine shape, architecture, echogenicity and diameter were monitored with ultrasonography in 11 Korea Jin-do dogs. Serial ultrasonographic examination was done daily during the first week, 3 days interval from 8 to 30 days, and weekly from 31 to 100 days postpartum, respectively. Of 11 postpartum bitches, 10 bitches (90.9%) had normal involution and 1 bitch (9.1%) had subinvolution of the placental sites (SIPS) by gross findings, vaginal discharges, and by ultrasographic findings, uterine shape and echogenicity. The excretory period of vaginal discharges in 10 normal bitches of uterine involution was finished completely at $20.2{\pm}4.6$ days (Mean${\pm}$SD) postpartum, but in 1 SIPS at 50 days postpartum. The short axis shape of the uterus was initially often flaccid-appearing. It varied from circular to crescent shaped to polygonal. This lasted until $16.5{\pm}3.7$ days postpartum, during which time the short axis uterine shape gradually changed to circular. Also, the long axis shape of the uterus was created a beaded appearance of the horns until $29.9{\pm}3.2$ days postpartum. After 30 days, it was appeared as tubular shape without distinguished between placental and interplacental sites. The ultrasonographic image of the postpartum uterus consisted of four echogenicity distinct layers. Uterine wall was represented the very hyperechoic serosa, hypoechoic myometrium, hyper echoic endometrium and anechoic structures of fluid in the uterine cavity until 7 days postpartum. The individual uterine layers were most prominent during the first week postpartum, and they became progressively less distinct throughout the course of uterine involution. Anechoic structures of fluid in the uterine cavity was detected until $25.0{\pm}6.4$ days postpartum, after which time it was not reliably detected. The uterine diameter was decreased not only in the placental sites frorm $24.1{\pm}2.5mm$ at 1 day to $15.4{\pm}1.4mm$ at 7 days postpartum, but also in the interplacental sites $14.9{\pm}1.5mm$ at 1 day, $10.6{\pm}0.8mm$ at 7 days postpartum. There was a general trend of decreasing uterine diameter, which occurred more rapidly at the placental sites. At 31 days pastpartum, these diameter reached almost same size, after that time, they could be not distinguished between placental and interplacental sites. At 87 days postpartum, the uterine diameter was $5.6{\pm}0.6mm$ both placental and interplacental sites, and the uterine horns were uniform hypoechoic, tubular structures without enlargement. Therefore, complete involution of the uterus occurred at that time. It was concluded that normal postpartum uterine involution in Korea Jin-do bitches appeared to be completed around 87 days postpartum by gross findings such as vaginal discharges, and by ultrasonographic findings, uterine shape and echogenicity. Also ultrasonographic characteristics of the postpartum uterine involution were described. Therefore, these result suggest that ultrasonographic assessment is a reliable method for diagnosing the SIPS and uterine dysfunction, such as pyometra in bitch.

  • PDF

The Value of Ultrasonographic Endometrial Measurement in the Prediction of Pregnancy Outcome in In Vitro Fertilization (체외수정시술 주기에서 자궁내막발달과 착상에 관한 연구)

  • Kim, Sun-Haeng
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.20 no.2
    • /
    • pp.117-123
    • /
    • 1993
  • The condition of the endometrium is an important factor which may influence the success or failure in IVF-ET. This study was undertaken for evaluation of the value of endometrial growth as an early predictor for the success of IVF. Ultrasonographic endometrial measurement were performed in 43 IVF cycles that conceived, 101 cycles that did not with an IVF-ET There was no significant difference in the endometrial thickness and the serum concentration of estradiol in the pregnant versus nonpregnant group(10.4 vs. 9.9 mm: 2348 vs. 2017 pg/ml no hCG administration day). No correlation was found between the ultrasound image and serum estradiol levels around the time of hCG administration(r=0.54, p=0.13 no Day 2; r=0.45, p=0.14 no Day 1). The duration of gonadotropin treatment, number of follicles, number of oocytes retrieved, and fertilization rate were not statistically different in the two groups, however, there was a significant difference in the number of embryos in the pregnant versus nonpregnant group)p< 0.05). A higher pregnancy rate and ongoing pregnancy rate occured with an endometrial thickness over 11 mm compared with below 7mm(p< 0.05, p< 0.005). however, no significant differences were noted in the implantation rate and abortion rate among the groups that classified according to their endmetrial thickness. The endometrial growth(${\Delta}$) from hCG administration day(DO) to D6 was greater in the women who achieved pregnancy than in the nonpregnant group(p< 0.01). There were no significant differences in serum estradiol levels, implantation rate, pregnancy rate, and abortion rate among the groups that classified according to the pattern of echogenesity of endometrium, however, significantly higher ongoing pregnancy rate was noted in group A, B compared with group C.(p< 0.0001, p< 0.001) These results suggest that there were no ultrasonographically detectable differences in the patterns of endometrial growth and development around the time of hCG administration in patients who conceive versus those that do not in IVF-ET.

  • PDF

Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints (측두하악관절 주변인대 질환의 초음파영상)

  • Hong, Soo-Min;Im, Yeong-Gwan;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2008
  • Purpose : The purpose of this study was to verify the usefulness and feasibility of ultrasonographic imaging for the detection of the disorders of the surrounding supporting structure such as articular capsule, retrodiscal tissue and related ligaments, osteoarthritic evidence and associated disc displacement at the temporomandibular joint(TMJ) Materials and Methods : 20 patients(40 joints) with periodic lock and crepitations were investigated prospectively using 12 MHz array transducer. Ultrasonographic Imagings were assessed for osteoarthritic surface changes of condyle, extent of disc displacement and disorders of surrounding structures. Ultrasonographic images were compared with clinical investigations, conventional radiography and Dental Computed Tomographic scans. Results : In clinical and conventional radiography, osteoarthritic changes were diagnosed in 8 joints. Ultrasonographically 7 of the 8 osteoarthritic changes were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 87.5%, 62.5%, and 67.5% respectively. About the detection of disc displacement, disc displacement were diagnosed in 21 joints clinically. Ultrasonographically 19 of the 21 disc displacements were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 95%, 90%, and 92.5% respectively. when the disorders of supportive structure were figured out, the disorders of supportive structure were diagnosed in 18 joints clinically. Ultrasonographically 1 of the 18 the disorders of supportive structure were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 5.5%, 4.5%, and 55% respectively. Conclusion : Ultrasonography is an relatively reliable diagnostic tool for the detection of disc displacement and some of osteoarthritic changes. But it's not an insufficient imaging technique for the detection of the disorders of the surrounding structure.

Sonogram of coccygeus muscle in dairy cows with different gestational ages

  • Ulum, Mokhamad Fakhrul;Frastantie, Dilla;Purwantara, Bambang
    • Journal of Animal Science and Technology
    • /
    • v.59 no.12
    • /
    • pp.26.1-26.8
    • /
    • 2017
  • Background: The change in size and weight of the female reproductive organs during gestation and birth might be affect the perineal muscles and this condition in dairy cow not been reported. This study aimed to assess the ultrasonographic image of coccygeus muscle in 11 inseminated dairy cows with different gestational ages and postpartum. Methods: Gestational age was calculated based on the record of artificial insemination and confirmed by using transrectal brightness mode ultrasonography. Perineal hair between the sacrum and ischium bones was shaved along 3-5 cm before being ultrasound. The images of perineal area were obtained by transcutaneous ultrasound using a 5.0 MHz transducer. The thickness and intensity of the coccygeus muscle were measured and analyzed by gestational status and postpartum to show the differences. Results: The results showed that the thickness of coccygeus muscle increased with the increase in gestational age. Muscle intensity only increased at young gestational age. However, it decreased with the increase in gestational age (P < 0.05). Conclusions: The ultrasound image of coccygeus muscle was affected by gestational status, thus this method may be used as one of the new methods of indirect gestational detection on dairy cows.

Neurilemmoma of Deep Peroneal Nerve Sensory Branch : Thermographic Findings with Compression Test

  • Ryu, Seung Jun;Zhang, Ho Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.286-290
    • /
    • 2015
  • We report a case of neurilemmoma of deep peroneal nerve sensory branch that triggered sensory change with compression test on lower extremity. After resection of tumor, there are evoked thermal changes on pre- and post-operative infrared (IR) thermographic images. A 52-year-old female presented with low back pain, sciatica, and sensory change on the dorsal side of the right foot and big toe that has lasted for 9 months. She also presented with right tibial mass sized 1.2 cm by 1.4 cm. Ultrasonographic imaging revealed a peripheral nerve sheath tumor arising from the peroneal nerve. IR thermographic image showed hyperthermia when the neurilemoma induced sensory change with compression test on the fibular area, dorsum of foot, and big toe. After surgery, the symptoms and thermographic changes were relieved and disappeared. The clinical, surgical, radiographic, and thermographic perspectives regarding this case are discussed.

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

Diagnostic Imaging of Massive Hepatocellular Carcinoma in 5 Dogs (개의 종괴형 간세포암종에 대한 진단 영상 소견에 대한 고찰)

  • Choi, Ji-Hye;Kim, Ah-Rim;Keh, Seo-Yeon;Choi, Hee-Yeon;Jang, Jae-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.474-482
    • /
    • 2010
  • Hepatocellular carcinoma (HCC) is a primary hepatic neoplasms in dogs. Three types of HCC such as massive, nodular and diffuse form were reported. Massive HCC is most common and has relatively better prognosis than other forms because this type of HCC can be removed surgically and has low frequency of relapse or metastasis. Diagnostic image can provide useful information for shape and internal structure of the hepatic mass as well as the location and adhesion or invasiveness of the mass to establish surgical plan to remove the mass safely. In this study, we investigated diagnostic features of massive HCC in 5 dogs. Radiography showed soft tissue mass in cranial abdomen in 3 dogs. On ultrasonography, all dogs had a solitary hepatic mass with mixed echo pattern with anechoic cysts, which represented necrosis and hemorrhage. The radiographic and ultrasonographic findings of affected hepatic lobe were compared with the macroscopic findings through laparotomy. Computed tomography was performed to check metastasis and figure out the origin of the mass in two dogs. Ultrasonography is useful and relatively sensitive examination for diagnosis and planning for surgery in canine massive HCC.

Digital Scan Converter Algorithm for Ultrsound Sector Scanner (초음파 섹터 스캐너를 위한 디지털 스캔 변환 기법)

  • 김근호;오정환
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.469-478
    • /
    • 1996
  • In the conventional digital ultrasound scanner, the reflected signal is sampled either in polar coordinates of R-$\theta$ method, or in Cartesian coordinates of uniform ladder algorithm (ULA). The R-$\theta$ scan method necessitates a coordinate transform process which makes hardware complex in comparison with ULA scan mrthoA In spite of this complexity, R-$\theta$ method has a good resolution in ultrasonographic (US) image, since scan direction of the US imaging is a radial direction. In this paper, a new digital scan converter is proposed, which is named the radius uniform ladder algorithm (RULA). The RULA has the rome scan direction as the US scanning in the radial direction and as the display space in the $\theta$ direction. In tllis new approach, sampled points we uniformly distributed in each horizontal line i.n well as in each radial ray so that the data are displayed in the Cartesian coordinates by the 1-D interpolation process. The propped algorithm has an uniform resolution in the periphery and the center field in comparison with equi-angle ULA and equi-interval ULA. To extend the scan angle, concentric square raster sampling (CSRS) is adopted with reduction of discontinuities on the junctions between horizontal scan and vertical scan. The discontinuities are reduced by using the hmction filtering along the $\theta$ direction.

  • PDF