• Title/Summary/Keyword: Ultrasonic wave

Search Result 1,020, Processing Time 0.024 seconds

A Study on the Evaluation of Material Degradation for 1Cr-1Mo-0.25V Steel using Linear and Nonlinear Ultrasonics (선형 및 비선형 초음파를 이용한 1Cr-1Mo-0.25V의 열화평가에 관한 연구)

  • Kim, Jeong-Pyo;Seok, Chang-Sung;Song, Sung-Jin;Kim, Young-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.549-555
    • /
    • 2001
  • Ultrasonic is a powerful nondestructive technique for getting the information of flaws and material properties of in-services facilities. We prepared 4 different 1Cr-1Mo-0.25V specimens by Isothermal aging at $630^{\circ}C$. We evaluated material degradation using ultrasonic parameters, velocity, attenuation and harmonic generation. Attenuation and nonlinear parameter derived from harmonic generation efficiency increased as degradation. Especially the second harmonic of the fundamental wave in the 1,820h aging material was observed to exceed 20dB more than that in the un-aged material. But velocity remained virtually the same for all specimens. We concluded that nonlinear parameter and attenuation are sensitive to material degradation, but velocity was not. It'll be a good parameter for evaluating the material degradation.

  • PDF

Ultrasonic Characterization on Sequences of CFRP Composites Based on Modeling and Motorized System

  • Im, Kwang-Hee;David K. Hsu;Song, Sung-Jin;Park, Je-Woung;Sim, Jae-Ki;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.65-73
    • /
    • 2004
  • Composites are a material class for which nondestructive material property characterization is as important as flaw detection. Laminates of fiber reinforced composites often possess strong in-plane elastic anisotropy attributable to the specific fiber orientation and layup sequence when waves are propagating in the thickness direction of composite laminates. So the layup orientation greatly influences its properties in a composite laminate. It could result in the part being .ejected and discarded if the layup orientation of a ply is misaligned. A nondestructive technique would be very beneficial, which could be used to test the part after curing and requires less time than the optical test. Therefore a ply-by-ply vector decomposition model has been developed, simplified, and implemented for composite laminates fabricated from unidirectional plies. This model decomposes the transmission of a linearly polarized ultrasound wave into orthogonal components through each ply of a laminate. Also in order to develop these methods into practical inspection tools, motorized system have been developed for different measurement modalities for acquiring ultrasonic signals as a function of in-plane angle. It is found that high probability shows between the model and tests developed in characterizing cured layups of the laminates.

Variation of Fatigue Properties in Nanoskinned Ti-6Al-4V - Rotating Bending and Axial Loading Tension-Compression Cycle - (Ti-6Al-4V 재의 UNSM 처리에 의한 피로특성변화 - 회전굽힘 피로시험과 축하중 인장압축 피로시험 비교 -)

  • Suh, Min-Soo;Pyoun, Young-Shik;Suh, Chang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.443-449
    • /
    • 2012
  • Nanoskins were fabricated on a Ti-6Al-4V material by carrying out various surface treatments, i.e., deep rolling, laser shot peening, and ultrasonic nanocrystal surface modification (UNSM). These surface treatments are newly developed techniques and are becoming more popular for industrial applications. Fatigue tests were carried out using material test system (MTS); these tests included the axial loading tension-compression fatigue test (R = -1, RT, 5 Hz, sinusoidal wave) and rotating bending fatigue test (R = -1, RT, 3200 rpm). The analysis of the crack initiation pattern in the UNSM-treated material indicated that the crack was interior originating in the axial loading tension-compression cycle, and was surface originating in the bending fatigue test. UNSM treatment significantly improved the fatigue strength for the regime of above $10^6$ cycles that S-N curve of rotating bending stress clearly show the performance of a 5 mm titanium specimen after UNSM treatment is similar to that of an untreated 6 mm titanium specimen.

Ultrasonic Nondestructive Evaluation of Creep-Induced Cavities (크리프 기공의 초음파 비파괴평가에 관한 연구)

  • Jang, Young-Su;Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.110-117
    • /
    • 1999
  • In order to ultrasonically evaluate creep cavities pure copper samples were subjected to creep test and their microstructures were examined. Ultrasonic velocities. frequency-dependent magnitude spectra and attenuations were measured on a series of copper samples obtained from the different stages of creep test. Velocities measured in three directions with respect to the loading axis decreased and their anisotropy increased as a function of the creep-induced porosity. The anisotropic behavior could be attributed to the progressive change of pore shape and preferred orientation as the creep advanced. The 2% porosity by volume decreased the longitudinal and shear wave velocities by 11% and 4%, respectively. Furthermore, both velocities decreased nonlinearly with the porosity. As the creep damage developed, the magnitude spectra lost high frequency components and their central frequencies shifted to lower values. The attenuation showed almost linear behavior in the frequency range used. Normalized velocity, central frequency shift and attenuation slope were selected as nondestructive evaluation parameters. These results were presented and showed good relations with the porosity content.

  • PDF

Assessment of Fatigue Damage of Adhesively Bonded Composite -Metal Joints by Acousto-Ultrasonics and Acoustic Emission (음향초음파와 음향방출에 의한 복합재료-금속 접착접합부의 피로손상 평가)

  • Kwon, Oh-Yang;Lee, Kyung-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.425-433
    • /
    • 2001
  • A correlation between fatigue damage and acousto-ultrasonic (AU) parameters has been obtained from signals acquired during fatigue loading of the single-lap joints of a carbon-fiber reinforced plastic (CFRP) laminates and A16061 plate. The correlation showed an analogy to those representing the stiffness reduction $(E/E_0)$ of polymer matrix composites by the accumulation of fatigue damage. This has been attributed to the transmission characteristics of acoustic wave energy through bonded joints with delamination-type defects and their influence on the change of spectral content of AU signals. Another correlation between fatigue cycles and the spectral magnitude of acoustic emission (AE) signals has also been found during the final stage of fatigue loading. Both AU and AE can be applied almost in real-time to monitor the evolution of damage during fatigue loading.

  • PDF

A Sham Experiment for the Measurement of Nonlinear Pulse Propagation Characteristics of Blood Vessel Using Bispectral Analysis (바이스펙트럼해석을 이용한 혈관의 비선형 맥동전파특성 계측에 대한 모의실험)

  • 장경영;김경조
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.525-532
    • /
    • 1995
  • In this paper, a new try to measure nonlinear propagation characteristics of the pulse along blood vessel by using bispectral analysis is introduced, and the possibility of its application to the medical diagnosis is shown. In this method, the waveforms of pulse motion of blood vessel at two separated measuring points on the wall were detected from Doppler frequency modulation of transmitted probing ultrasonic waves. Then the auto- and crossbispectrum of detected waveforms are calculated to estimate the quadratic NTF (nonlinear transfer function) between the two measuring positions. In order to show relationships between the NTF and the nonlinear propagation characteristics, computer simulations have been performed. As the propagation distance increases, harmonic frequency components in NTF increases broadly due to the nonlinear effect in the propagation of blood pulse. In order to represent this phenomena quantitatively, we propose a new parameter, dispersion ratio of WTF. Basic experimental system was constructed by using 3.5MHz probing ultrasonic waves and the preliminary experiments were carried out on ague phantom and human body. Experimental results showed the validity of the measurement system enoughly.

  • PDF

Non-contact Transportation of Flat Panel Substrate by Combined Ultrasonic Acoustic Viscous and Aerostatic Forces

  • Isobe, Hiromi;Fushimi, Masaaki;Ootsuka, Masami;Kyusojin, Akira
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.44-48
    • /
    • 2007
  • In recent years, the size of plane substrates and semiconductor wafers has increased. As conventional contact transportation systems composed of, for example, carrier rollers, belt conveyers, and robot hands carry these longer and wider substrates, the increased weight results in increased potential for fracture. A noncontact transportation system is required to solve this problem. We propose a new noncontact transportation system combining acoustic viscous and aerostatic forces to provide damage-free transport. In this system, substrates are supported by aerostatic force and transported by acoustic viscous streaming induced by traveling wave deformation of a disk-type stator. A ring-type piezoelectric transducer bonded on the stator excites vibration. A stator with a high Q piezoelectric transducer can generate traveling vibrations with amplitude of $3.2{\mu}m$. Prior to constructing a carrying road for substrates, we clarified the basic properties of this technique and stator vibration characteristics experimentally. We constructed the experimental equipment using a rotational disk with a 95-mm diameter. Electric power was 70 W at an input voltage of 200 Vpp. A rotational torque of $8.5\times10^{-5}Nm$ was obtained when clearance between the stator and disk was $120{\mu}m$. Finally, we constructed a noncontact transport apparatus for polycrystalline silicon wafers $(150(W)\times150(L)\times0.3(t))$, producing a carrying speed of 59.2 mm/s at a clearance of 0.3 mm between the stator and wafer. The carrying force when four stators acted on the wafer was $2\times10^{-3}N$. Thus, the new noncontact transportation system was demonstrated to be effective.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

Solid Phase Extraction(SPE) of Curcuminoids from Turmeric by Optimization Analytical Condition (최적 분석조건에 의한 강황으로부터 Curcuminoids의 고체상추출(SPE))

  • Lee, Kwang Jin;Ma, Jin Yeul;Kim, Young Jun;Kim, Young Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4927-4935
    • /
    • 2012
  • Turmeric is a medicinal herb with various pharmacological activities. Curcumin, demethoxycurcumin(DMC) and bisdemethoxycurcumin(BDMC) were extracted from turmeric by dipping and ultrasonic wave method. And extraction efficiency was identified using solid phase extraction(SPE). The extracted sample were simultaneously separated and analyzed from three kinds of commercial $C_{18}$ reversed-phase high performance liquid chromatography using water and acetonitrile as mobile phase with isocratic elution mode. Flow rate 1.0mL/min, injection volume $10{\mu}L$ and column oven temperature $40^{\circ}C$ at 425nm wavelength has been conducted. From the experimental results, the optimum mobile phase composition of water/acetonitrile 50/50vol% using RS tech column. It is evident that the amount of curcuminoids extracted(extraction time 4h) by 100% MeOH was higher than any aqueous MeOH composition. Finally, in 100% water extraction, the amount(mAU${\times}$mim) of curcuminoids extracted by SPE was 14.3 and 24.5 times respectively higher than ultrasonic wave and dipping method. The shown results can be applied as sources for pharmaceuticals and functional material.

sound Velocity and Attenuation Coefficient in the Core Sediment of Deep-Sea Basin, East Sea of Korea (Sea of Japan) (동해 심해분지 시추퇴적물의 음속과 감쇠계수)

  • 김성렬;이용국
    • 한국해양학회지
    • /
    • v.26 no.1
    • /
    • pp.59-66
    • /
    • 1991
  • Laboratory studies were carried out to measure the sound velocity (V/SUB p/) and quality factor (Q/SUB p/, inverse attenuation) in the horizontal (H) and vertical (V) direction on the core sampled sediment of deep-sea basin (1,850 meter water depth), East Sea of Korea (Sea of Japan). Sampled core was about 250 cm long and 500 kHz ultrasonic p-wave transducer was used for a sound soured. V/SUB p/ varies from 1,480 m/sec to 1,500 m/sec, it is not clear which direction is faster, V/SUB PH/ or V/SUB pv/, within${\pm}$ 1.0% anisotropy (A/SUB p/). It is thought because the core sediment facies is highly (or slightly) bioturbated homogeneous mud with very high porosity (more than 80%). The general trend of Q/SUB p/ is decreasing 10 to 5 with the buried depth, it is strongly affected by the variation of sediment texture (increasing silt, decreasing clay) with increasing of CaCO$_3$ and organic matter content, But Q/SUB PH/ is jumping up to 14.9 near the bottom of core sediment as including volcanic ash richly. The relationship between V/SUB PH/ and Q/SUB PH/ shows the mirror image nearly, it is interpreted that not only the geotechnical properties and texture but also sea-water characteristics (high Q/SUB p/, low V/SUB p/) according to rich water content affect strongly in the upper part of the unconsolidated deep-sea basin sediment.

  • PDF