• 제목/요약/키워드: Ultrasonic measurement method

검색결과 441건 처리시간 0.056초

Material Evaluation of Lead Die-Casted Positive Grid for Battery Using Nondestructive Evaluation Technique (연축전지 양극기판의 기계적 특성비교 분석 및 비 파괴 평가기법의 적용)

  • Kim, Hui-Jung;Lee, Min-Rae;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제26권8호
    • /
    • pp.1709-1718
    • /
    • 2002
  • It is well recognized that improving capacity of positive grid in battery is one of key factors for controlling the expected long lift-time of Battery Energy Storage System(B.E.S.S). Thus it is really important to characterized material properties of positive grid which are mainly affected by fabrication process. In this study, two kinds of positive grids, which were fabricated by gravity casting and die-casting technique were used. Micro-structural observation and tensile test were conducted to investigate the effect of fabrication process of positive grid. Ultrasonic measurement based on pulse-echo method and ultrasonic C-scan technique also performed to correlate ultrasonic velocity with porosity ratio in positive grid. It was found that the porosity ratio of grid fabricated by gravity casting technique increased significantly compared to the grid fabricated by die-casting technique. It was also shown that ulrasonic technique is effective to evaluate the porosity ratio in positive grid.

A Study on the Thickness Measurement of Thin Film and the Flaw Detection of the Interface by Digital Signal Processing (디지털 신호처리에 의한 박판두께측정 및 접합경계면의 결함검출에 관한 연구)

  • Kim, Jae-Yeol;Yiu, Shin;Kim, Byung-Hyun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.123-127
    • /
    • 1997
  • Recently, it is gradually raised necessity that interface is measured accurately and managed in industrial circles and medical world, An Ultrasonic wave transmitted from a focused beam transducer is being expected as a powerful tool for NDE of micro-defect. The ultrasonic NDE of the defect is based on the form of the wave reflected form the interface In this study, regarding to the thickness of film which is in opaque object and thickness measurement was done by MEM-cepstrum analysis of received ultrasonic wave. In measument results, film thickness which is beyond distance resolution capacity was measured accurately. Also, automatically repeated discrimination analysis method can be decided in the category of all kinds of defects on semiconductor package.

  • PDF

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • 제27권5호
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Burning Rate Testing of Double Base Solid Propellants using Ultrasound (초음파를 이용한 Double Base형 고체추진제의 연소속도 측정)

  • Song, Sung-Jin;Ko, Sun-Feel;Kim, Hak-Joon;Oh, Hyun-Taek;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.247-250
    • /
    • 2006
  • In the previous study, we have developed an ultrasonic measurement system and analysis technique for borning rate testing of solid propellants using ultrasound. And then, using the developed system, burning rate of composite propellants were measured. So, in this study, we performed measurement of double base solid propellant, which has non-linear homing rate as pressure increasing, using the developed system in order to evaluate capability of ultrasonic method. Furthermore, accuracy of measured homing rates using ultrasound was verified by comparison to homing rate measured by the strand burner method.

  • PDF

A Development of Acoustic Release System in the Seafloor (심해저용 원격 착탈 제어 시스템의 개발)

  • Kim, Young-Jin;Huh, Kyung-Moo;Jeong, Han-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제11권9호
    • /
    • pp.774-780
    • /
    • 2005
  • For the accurate inspection of the resources and space in the ocean, the method of locating the measurement equipments in the seafloor and retrieving these equipments later after a certain period of time. is generally used. In this method, the reliability of retrieving measurement equipments is very important. In our proposed remotely-controlled acoustic release system, an underwater ultrasonic wave recognition algorithm by which we can recognize the sound signal without the influence of disturbances due to underwater environment changes is developed, and a battery is used for the reduction of electric power consumption. we show the effectiveness of our proposed system through experimental results.

Bonding Strength Analysis of Structural Joints by using Ultrasonic Method (초음파법을 이용한 구조이음의 접합강도해석)

  • Jang Chul Sub;Oh Seung Kyu;Yi Won
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • 제14권2호
    • /
    • pp.104-109
    • /
    • 2005
  • This article has been investigated the use of FFT for adhesive joints analysis between metal sheets. The method is based on the measurement of the reflection wave at the metal/adhesive interface. After describing briefly the physical aspects of the phenomenon, an index is defined to detect defective zone of the joint(both for the lack of adhesive and for insufficient adhesion): the influence of the experimental variables(variable stress...) on the measurement is discussed. By means of a control experiment it is shown that stress variation in adhesive joints are separate to be distinguished. In this paper, Nondestructive evaluation in adhesive joints are evaluated together with ultrasonic testing and finite element analysis.

Elastic modulus measurement of thin films using laser generated guided ultrasonic waves (레이저 초음파 기법을 이용한 박막 탄성계수 측정)

  • Cho, Seung Hyun;Heo, Taehoon;Ji, Bonggyu;Ahn, Bongyoung;Jang, Gang-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.550-554
    • /
    • 2014
  • Regarding thin films in MEMS/NEMS structures, the exact evaluation of mechanical properties is very essential to enhance the reliability of their design and manufacturing. However, such methods as a tensile test and a resonance test, general methods to measure elastic moduli, cannot be applied to thin films since its thickness is so small. This work concerns guided wave based elastic modulus measurement method. To this end, guided wave excitation and detection system using a pulsed laser and a laser interferometry has been established. Also an elastic modulus extraction algorithm from the measured guided wave signal was developed. Finally, it was applied to actual thin film structures such as Ni-Si and Al-Si multilayers. From experimental results, we confirm that the proposed method has considerable feasibility to measure elastic properties of thin films.

  • PDF

An Experimental Study on the Evaluation of Injection-ability for Concrete Crack-Repair Materials by using Ultrasonic Pulse Measurement Method. (초음파 측정법을 이용한 콘크리트 균열보수재의 충전성능 평가에 관한 실험적 연구)

  • Lee, Sang-Hyun;Lee, Han-Seung;Park, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.515-518
    • /
    • 2005
  • A concrete is easy to happen crack. So it requires crack-repair work to solve quality deteriorations of a building because of cracks. When crack is filled with crack-repair materials, it is difficult to find out how depth it was injected. So in this study we evaluated the injection depth with using indirect and oblique methods, ultrasonic pulse measurement method of NDT. The results of this study showed that both methods are possible to evalute penetration depth of crack-repair materials and indirect methods is thought to be more useful one than obliqure one.

  • PDF

Poisson's Ratio Scanning Using Immersion Ultrasonic Testing

  • Oh, Seo-Young;Kim, Young-H.;Shin, Yo-Sub;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제28권6호
    • /
    • pp.519-523
    • /
    • 2008
  • Poisson's ratio is one of elastic constants of elastic solids. However, it has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Hard couplant for transverse wave prevents transducer from scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was proposed. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected. Transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio can be determined without information of specimen thickness. This technique was demonstrated for aluminum and steel specimens.

A Design of a Mobile Robot for Blind Guidance (맹인 안내용 모빌로보트의 설계)

  • 유상열;이응혁
    • Journal of Biomedical Engineering Research
    • /
    • 제6권2호
    • /
    • pp.33-42
    • /
    • 1985
  • In this paper, a mobile robot is designed for the blind guidance. This system is composed of an Ultrasonic Ranging Vnit, PWM Vnit, Optical Encoder Vnit. Specilly we adapted Distance Comparison Measurement Method (DCMM) in order to compensate for the error resulted from atmospheric conditions, and PWM unit for the vehicle control and Optical encoder unit for the correct locomotion control. This system is processed, using MCS-85 microcomputer, much of information on surrounding conduitions in real time. We rotated ultrasonic sensor for many sifted data acquisition and used tone generator for the Man-Machine Communication. As a result, the measurement error of the distance is about 1cm, the distance measurement could be detected 0.2m to 6m. The locomotion speed is 0.4m/sec and we examined its practical use.

  • PDF