• 제목/요약/키워드: Ultrasonic distance measurement

검색결과 97건 처리시간 0.028초

Recognition resolution enhancement of ultrasonic sensors via multiple steps of transmitter voltages

  • Na, Seung-You;Park, Min-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.409-412
    • /
    • 1996
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensing are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensor has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained with neither the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권1호
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

위상시간법에 의한 초음파전파시간의 결정에 관한 연구 (A study on the determination of Ultrasonic Travel Time by Norm Phase-Time Method)

  • 이은방
    • 한국항해학회지
    • /
    • 제18권4호
    • /
    • pp.137-146
    • /
    • 1994
  • In this paper, a new algorithm to measure the ultrasonic travel time is proposed, which is fundamental to estimate distance depth and volume in several media. Pulse wave has been used to measure travel time of transmitted signal. However, due to the characteristic of transducer and propagation, the received signal is so distorted that it is difficult to measure travel time, which is propagation, the received signal is so distorted that it is difficult to measure travel time, which is to be time difference between transmitted and received signals. In this proposed method, transmitted and received signal are transformed respectively into norm phase newly designed by this paper and displayed on phase-time curve. And travel time is simply determined by the arithmetic numerical mean of time difference at the identical norm phase on the phase-time curves of transmitted and received signals. This method has several features; firstly, travel time is calculated analytically with high accuracy by least square error method, secondly, it is useful to compare the difference of signal magnitude for time information, thirdly, noise and discrete errors are relatively small, finally, the measurement accuracy is not influenced by D.C. bias. In particular, this method is useful and applicable to measuring very short distance and sound speed with high accuracy.

  • PDF

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

광패턴을 이용한 능동형 수위 및 거리 측정 기법 (Active Water-Level and Distance Measurement Algorithm using Light Beam Pattern)

  • 김낙우;손승철;이문섭;민기현;이병탁
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.156-163
    • /
    • 2015
  • 본 논문은 광패턴 조사를 통한 능동형 수위 및 거리 측정 기법을 제안한다. 기존 압력식, 부자식, 초음파식, 레이더식 등의 수위측정기법과 달리 최근에는 수위측정의 정확성과 모니터링 편리성을 강조한 영상기반 수위측정기법이 활용되고 있다. 본 논문에서는 참조용 광패턴을 교각이나 제방 등에 동적으로 조사(照射)하고, 카메라 장치로부터 조사된 광패턴 영상을 실시간 분석 처리하여 자동 수위측정 및 조사(照射) 대상물까지의 거리측정을 위한 새로운 방법을 제시한다. 기존 방법이 교각에 기(旣) 부착된 수위표나 마커 인식을 위해 수동적으로 영상데이터를 분석하는 것이었다면, 본 기법은 교각 설치 환경에 대응하여 능동적으로 참조 광패턴을 생성하여 사용함으로써, 난시야(難視野) 환경 및 잡음 대응에 효과적이고, 포터블 형태로 주야간 이용이 가능하며, 별도 조명 설치를 요구하지 않는 등의 강건한 수위 측정을 지원한다. 본 실험은 실내 시험 환경을 구성하여 시뮬레이션 하였으며, 0.4-1.4m 거리 13.5-32.5cm 높이에서 수위 및 거리 측정을 수행하였다.

시각장애자의 보행지원에 관한 연구 (A study on walking aids for the blind)

  • 함광근;한상휘;양승열;김현규;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.131-135
    • /
    • 1997
  • We implementated an ultrasonic wave cane for the blind. The cane detect walking obstacle and provide a walking direction. The cane used time of flight method of ultrasonic-wave for a measurement of obstacle distance and fluxgate geomagnetic sensor for guidance of walking direction. This system can detect an obstacle of upward, forward, downward and that warn to the blind with vibration, pitch sound. And the blind can know walking direction to voice output. As a result, the blind could efficiently avoid a exposed obstacle, obstacles beyond knee, an exposed street obstacle, a branch of tree person's height and it is usable search for surrounding land mark.

  • PDF

회전속도와 탄성파를 동시에 측정하는 비접촉 자왜형 센서의 자기적 특성 분석 (Analysis of Magnetic Characteristics for a Noncontact Magnetostrictive Sensor Simultaneously Measuring Rotational Speed and Force)

  • 이호철
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.418-424
    • /
    • 2009
  • This work is the attempt to give qualitative explanations to complex magnetic phenomena which are observed in the previously proposed magnetostrictive sensor capable of ultrasonic waves and rotational speed measurement. The law of approach is adopted as analysis tool in order to account for some extraordinary output patterns and proved to be effective. The distance between the anhysteretic curve current magnetic state and the variation of anhysteretic curve by stress mainly determine the sensor output shapes and their uniqueness. It is also experimentally verified that the precisely determined bias magnetic field strength can not only remove the unusual output parts but also maximize its sensitivity.

초음파 뇨량검출 센서의 제작 및 방광 벽간거리와 뇨량과의 상관관계에 관한 연구 (A Study on the Development of Ultrasonic Urine Volume Detection Sensor and the Correlation between Urine Volume and Bladder Interwall Distance)

  • 최흥호;이응혁
    • 센서학회지
    • /
    • 제9권4호
    • /
    • pp.256-267
    • /
    • 2000
  • 본 논문에서는 뇨실금 환자들에 대한 지원 기술의 일환으로 인체에 무해하고 비침습적인 초음파를 이용하여 배뇨시기를 알려주는 뇨의 경보기용 뇨량검출 센서의 개발과 이를 이용한 방광 벽간거리와 뇨량과의 상관관계에 관하여 연구하였다. 개발된 센서의 중심 주파수는 2.25 MHz이며, 이는 인체내로의 침투력이 비교적 좋으면서도 분해능이 높아 오차를 감소시킬 수 있게 설계하였다. 이 센서를 이용하여 방광 전 후벽간의 거리를 검출하여 이로부터 뇨량을 정량적으로 측정하기 위한 기초 실험을 실시하였다. 기초실험은 건강한 성인 남자 3명을 대상으로 초음파 뇨량검출 센서를 이용한 초음파 RF 반사신호 획득장치와 초음파 진단기에 의한 2가지 방법으로 이루어졌고 그 결과 뇨량과 벽간거리와의 사이에는 높은 상관성이 있음을 확인할 수 있었다. 결론적으로, 실험 결과를 토대로 하여 제작된 초음파 뇨량검출용 센서는 뇨실금 환자로 하여금 배뇨시기를 알려주는 뇨의 경보 시스템으로 활용될 수 있으며, 보건 복지적인 측면에서 현대사회에 기여할 공헌도가 매우 클 것이라 생각된다.

  • PDF

초음파 센서 간 신호 간섭 제거 방법 (Removal Method of Signal Interference between Ultrasound Sensors)

  • 임형철;이성수
    • 전기전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.584-590
    • /
    • 2021
  • 본 논문에서는 초음파 센서로 거리를 측정할 때 간섭에 의해 발생하는 유령 신호를 배제하고 올바른 신호를 인식하는 초음파 센서 간 신호 간섭 제거 방안을 제시한다. 제안하는 기법에서는 이전 거리 측정 값과 현재 거리 측정 값을 비교하여 거리의 변화가 한계값을 벗어나면 유령 신호로 인식하고 배제한다. 기존 기법에서는 한계값이 고정되어 있어서 초음파 센서나 대상 물체가 급격하게 움직일 경우 유령 신호를 제대로 배제하기 어렵지만, 제안하는 기법에서는 한계값을 고정하지 않고 초음파 센서나 대상 물체가 움직일 경우 상대 속도에 따라 한계값을 적응적으로 결정하는 알고리즘을 사용하여 정확도를 높인다. 초음파 센서로 물체까지의 거리를 측정할 때 간섭이 가장 잘 일어나는 동종의 초음파 센서를 다수 사용하여 간섭 신호를 발생시키는 실험을 진행하였고 제안하는 기법이 효과적으로 유령 신호를 배제하는 것을 확인하였다.

거리측정용 PZT-고분자 3-3형 복합압전체 트랜스듀서의 펄스에코 응답특성 (Pulse-echo Response of Ultrasonic Transducer Fabricated by PZT-Polymer 3-3 Type Composite Resonator for Distance Measurement Applications)

  • 주용관;박정학;최헌일;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.205-208
    • /
    • 1995
  • PZT powders were prepared by the molten salt synthesis method. The porous PZT specimens were prepared from a mixture of PZT and Polyvinylalcohol(PVA) powders by BURPS(Burnout Plastic Sphere) technique. The pulse-echo response of PZT-polymer 3-3 type composite transducer with various PVA wt.% were studied, The fall time of pulse-echo response of PZT-polymer 3-3 type composite transducer was shorten to that of solid PZT-maded transducer. Therefore, a good transmitting and receiving properties could be obtained. The distance between transducer and reflector was in good agreement both solid PZT and PZT-polymer 3-3 type composite fabricated transducer.

  • PDF