• Title/Summary/Keyword: Ultrasonic diagnosis

Search Result 211, Processing Time 0.024 seconds

Clinically translatable photoacoustic imaging of cancer diagnosis (임상적용이 가능한 광음향 암 진단 기술)

  • Kim, Mi-Ji;Park, Yeon-Seong;Yoon, Changhan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.476-484
    • /
    • 2019
  • Photoacoustic imaging is a hybrid real-time imaging technique that combines high optical contrast and ultrasonic resolution. It has primarily been utilized in pre-clinical research and has evolved into clinical practice. In this paper, we review photoacosutic imaging for detection of primary canccer and metastatis and its limitation in translation from pre-clinical to clinical application.

Estimation of Compressive Strength of Reinforced Concrete Vertical and Horizontal Members Using Ultrasonic Pulse Velocity Method (초음파속도법을 이용한 철근콘크리트 수직 및 수평부재의 압축강도 추정)

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Kim, Jonghyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.197-205
    • /
    • 2018
  • Recently, remodeling is increasing due to aging of buildings. Therefore, the importance of quality control of structures has been raised, and interest in safety diagnosis and evaluation of structures has been increasing. In order to accurately diagnose old buildings, a diagnostic evaluation technique is needed to evaluate the defects of structures in advance. In addition, as the safety diagnostic criteria for reconstruction are improved and the weight of structural safety is increased, researches on safety diagnosis techniques of structures that are faster and more reliable are needed. In this study, we tried to estimate the compressive strength by examining the correlation between ultrasonic pulse velocity and compressive strength of a 1 story structure consisting of vertical and horizontal members of reinforced concrete using ultrasonic pulse velocity method, which is one of the nondestructive testing methods. The purpose of this study is to examine the applicability in the field. As a result, the estimated average error rate of the compressive strength of the structure using the ultrasonic pulse velocity method was 28.7%, which confirmed the applicability in the field. However, in order to increase the accuracy of the estimation, the necessity of the reliable diagnostic method using the composite nondestructive testing method was confirmed.

Dependences of Ultrasonic Parameters for Osteoporosis Diagnosis on Bone Mineral Density (골다공증 진단을 위한 초음파 변수의 골밀도에 대한 의존성)

  • Hwang, Kyo Seung;Kim, Yoon Mi;Park, Jong Chan;Choi, Min Joo;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.502-508
    • /
    • 2012
  • Quantitative ultrasound technologies for osteoporosis diagnosis measure ultrasonic parameters such as speed of sound(SOS) and normalized broadband ultrasound attenuation(nBUA) in the calcaneus (heel bone). In the present study, the dependences of SOS and nBUA on bone mineral density in the proximal femur with high risk of fracture were investigated by using 20 trabecular bone samples extracted from bovine femurs. SOS and nBUA in the femoral trabecular bone samples were measured by using a transverse transmission method with one matched pair of ultrasonic transducers with a center frequency of 1.0 MHz. SOS and nBUA measured in the 20 trabecular bone samples exhibited high Pearson's correlation coefficients (r) of r = 0.83 and 0.72 with apparent bone density, respectively. The multiple regression analysis with SOS and nBUA as independent variables and apparent bone density as a dependent variable showed that the correlation coefficient r = 0.85 of the multiple linear regression model was higher than those of the simple linear regression model with either parameter SOS or nBUA as an independent variable. These high linear correlations between the ultrasonic parameters and the bone density suggest that the ultrasonic parameters measured in the femur can be useful for predicting the femoral bone mineral density.

Establishment of Ultrasonic Measurement Method for Stone Cultural Heritage Considering Water Content and Anisotropy (함수율과 이방성을 고려한 석조문화유산의 초음파 측정방법 설정)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.467-480
    • /
    • 2014
  • This study was focused on measurement methods for stone cultural heritages by analyzing Ultrasonic (P-wave) velocity variations according to the water content and anisotropy of rocks. As a result of analyzing of rock properties, the water content and saturation degree were rapidly changed at the beginning of drying and then showed exponential curve which their rates of change gradually decreased. However, P-wave velocity and its rate of change maintained constant values after natural drying of 10 hours. Therefore, the ultrasonic measurement for stone cultural heritages should be performed after natural drying of 10 hours considering the weather and moisture conditions. In addition, the highest values of anisotropy coefficient exhibited in granite and limestone, and indirect method was insensitive to anisotropy compared to direct method. However, all rocks remained anisotropy by indirect method. Accordingly, ultrasonic measurement considering various directions is required. The research results will contribute to customized non-destructive testing and precise diagnosis for lithological characteristics of stone cultural heritage.

Position and Attitude Estimation of a Capsule Endoscope based on Ultrasonic Ranging (초음파 거리를 이용한 캡슐 내시경의 위치 및 자세각 추정)

  • Kim, Eun-Joung;Kim, Myung-Yu;Kim, Deok-Ki;Kim, Yong-Dae;You, Young-Gap
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.38-44
    • /
    • 2007
  • This paper presented a location and attitude estimation scheme of a capsule endoscope based on ultrasonic ranging. The scheme comprised eight on-capsule ultrasonic sensors to alleviate measurement errors due to irregularities in human body ultrasonic characteristics. It calculated the coordinate values and angles in a Cartesian coordinate system. The Matlab simulation reflecting random errors yielded the average deviations of 0.8mm in the location and $0.2^{\circ}$ in the attitude angle. These values are far smaller than normal intestine movement ranges inside human body, and will contribute accurate diagnosis of intestine.

Reliability improvement of nonlinear ultrasonic modulation based fatigue crack detection using feature-level data fusion

  • Lim, Hyung Jin;Kim, Yongtak;Sohn, Hoon;Jeon, Ikgeun;Liu, Peipei
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.683-696
    • /
    • 2017
  • In this study, the reliability of nonlinear ultrasonic modulation based fatigue crack detection is improved using a feature-level data fusion approach. When two ultrasonic inputs at two distinct frequencies are applied to a specimen with a fatigue crack, modulation components at the summation and difference of these two input frequencies appear. First, the spectral amplitudes of the modulation components and their spectral correlations are defined as individual features. Then, a 2D feature space is constructed by combining these two features, and the presence of a fatigue crack is identified in the feature space. The effectiveness of the proposed fatigue crack detection technique is experimentally validated through cyclic loading tests of aluminum plates, full-scale steel girders and a rotating shaft component. Subsequently, the improved reliability of the proposed technique is quantitatively investigated using receiver operating characteristic analysis. The uniqueness of this study lies in (1) improvement of nonlinear ultrasonic modulation based fatigue crack detection reliability using feature-level data fusion, (2) reference-free fatigue crack diagnosis without using the baseline data obtained from the intact condition of the structure, (3) application to full-scale steel girders and shaft component, and (4) quantitative investigation of the improved reliability using receiver operating characteristic analysis.

An Experimental Study for Supposed Heating Temperature of Deteriorated Concrete Structure by fire Accident (화재피해를 입은 콘크리트구조물의 수열온도 추정을 위한 실험적 연구)

  • 권영진
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.51-56
    • /
    • 2004
  • A fire outbreak in a reinforcement concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So concrete reinforcement structure is damaged partial or whole structure system. Therefore diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, it was presented data for the accurate diagnosis and selection of repair and reinforcement system for the deteriorated concrete heated highly, various concrete such as standard design compressive strength, fine aggregate and admixture were exposed to a high temperature environment. And fundamental data were measured engineering properties such as explosive spatting, ultrasonic pulse velocity and compressive strength.

Ultrasonographic Appearance in One Case of Renal Cell Carcinoma (위세포암(胃細胞癌) 1례(例)의 초음파상(超音波像)에 관(關)한 연구(硏究))

  • Han, Hye-Jin;Kim, Kang-Sueck
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.149-162
    • /
    • 1986
  • We had experienced very rare a case of renal cell carcinoma through ultrasonic diagnosis, september, 1985 at medical dept. Dae Han Kyoyuk Ins. Company. The conclusions that we gained, making a comparative-analysis of operation's view and ultrasonic view are as follows; 1. Echolucent area which was $0.6cm^2$ size in the center of tumor was shown by ultrasonography, we noticed it occured necrosis or cystic change and the extracts grossly after. operation accorded with ultrasonic view. 2. Tumor was 65mm in diameter on ultrasonography and made clear 55mm in diameter after operation 3. There was not fever, anemia, even typical triad of renal cell carcinoma, blood pressure was within normal limits. 4. The case was stage I by Robson's Modification method. 5. The case was clear cell type by classifying of histology. 6. The affected site was left side and origin was lower pole of the kidney. 7. After radical nephrectomy, until present prognosis was favorable and he exists.

  • PDF

Design and Fabrication of a Convex Array Ultrasonic Transducer with Finite Element Analysis (유한요소 해석법을 이용한 컨벡스 배열형 초음파 탐촉자의 설계 및 제작)

  • Lee, Su-Sung;Kwon, Jae-Hwa;Eun, Hong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.592-599
    • /
    • 2002
  • In this study, an ultrasonic transducer was designed with a commercial finite element analysis (FEA) code, PZFlex, and fabricated based on the design. The transducer has the dimension and shape suitable for abdomen diagnosis working at 5 ㎒ and consists of 128 piezoelectric elements disposed in a convex linear array form. The transducer is composed of two impedance matching layers, one backing layer, and kerfs placed between the piezoelectric elements. Validity of the design with the FEA was illustrated through experimental characterization of a sample transducer. Comparison with the design results by equivalent circuit analysis method was also made to check the superiority of the FEA design.

Speckle noise elimination of ultrasonic images by using generalized noise model and adaptive weighted median filter (일반형 잡음모델과 적응성 가중 메디안 필터를 이용한 초음파 영상의 스펙클 잡음 제거)

  • 윤귀영;안영복
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.7
    • /
    • pp.89-101
    • /
    • 1997
  • A technical method of noise modeling and adaptive filtering reducing of speckle noise in ultrasonic medical images is presented. By adjusting the characteristics of the filer according to local statistics around each pixel of the image as moving windowing, it is possible to suppress noise sufficiently while preserve edge and other significant information required in diagnosis. Homogeneous factor(HF) from the noise models that enables the filter to recognize the local structures of the image is introduced, and an algorithm for determining the HF fitted to the diagnostic systems with various inner statistical properties is proposed. We show by the experimented that the performance of proposed method is superior to these of other filters and models in preserving small details and suppressing the noise at homogeneous region.

  • PDF