• Title/Summary/Keyword: Ultrasonic diagnosis

검색결과 211건 처리시간 0.023초

초음파를 이용한 Bladder형태에 따른 잔뇨량 측정의 정확도 연구 (A Study on the Accuracy of Measurement of Residual Urine Amount depending on the Bladder form using Ultrasonic)

  • 김연민;박태훈;김진혁;김수지;조다훈;허진영;한동균
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to increase the accuracy of the diagnosis of benign prostatic hyperplasia by presenting a method that can accurately measure the residual urine amount of the bladder by using an ultrasound image. Agar powder, Propanol and distilled water were used as materials for making a phantom. In order to measure the volume, a $10m{\ell}$ cylinder, syringe and beaker were used. The image was obtained by scanning phantoms produced into six shapes. Each constant value was obtained by using the expression designed to measure the residual urine amount of the bladder and was compared and analyzed. The measuring method of Bladder volume was presented and a constant value for each shape was obtained and five observers measured it five times. According to the results of clinical application, the errors of Ellipse-beanbag, Shield-shield were 11.0%, 18.2%, respectively. Constant values depending on the shape of each phantom were presented in order to accurately measure the volume of the bladder in measuring the amount of residual urine for the diagnosis of benign prostatic hyperplasia. The accuracy of the volume using this was verified statistically(p > 0.05). Therefore, it is considered to be useful in diagnosing benign prostatic hyperplasia by using the ultrasound imaging measuring method presented.

  • PDF

한방소아과 설문지 및 검사에 관한 임상현황연구 (Clinical Investigation of Survey and Test in Korean Oriental Pediatrics)

  • 황영준;김기봉;민상연;김장현
    • 대한한방소아과학회지
    • /
    • 제22권1호
    • /
    • pp.25-34
    • /
    • 2008
  • Objectives The purpose of this study is to investigate whether Korean oriental pediatrics hospitals are using their feedback surveys to improve their medical conditions. Methods We selected 24 oriental medicine university hospitals and sent surveys to investigate. 15 of those surveys were analyzed. Results The results were classified as follows; Only 9 of university hospital said that they are currently using their feedback surveys to improve their services. Question for asking the purpose of doing their feedback surveys, 58.3% of hospital responded to get some information for diagnosis, 25% of them said to see the progress of treatment of specific disease, and 16.7% answered for using their data to the further studies. The question about the reason why hospital were need to make these feedback surveys, 46.2% of them answered to apply better service, 38.4% of them said to post medical journal. The question for asking what do oriental medical hospitals check from feedback surveys, 40% of them said they check Ryodoraku, 33.3% was pulse diagnostic apparatus, EAV(Electro-puncture According to Voll) was 26.7%. The classification according to purpose of test resulted as follows; information for diagnosis was 48.1%, the progress of a disease was 37.3%. In addition oriental medical test there were blood test, radiological test, brain waves test, Hair Tissue Mineral Analysis(HTMA), ultrasonic test, body composition analysis. Conclusions Further clinical research is necessary for improvement of using the feedback survey effectively.

  • PDF

한국산 잡견에서 신장의 초음파검사법 (Ultrasonography of the Kidney in Mongrel Dogs in Korea)

  • 김명철;박관호;박종오;김영범
    • 한국임상수의학회지
    • /
    • 제10권2호
    • /
    • pp.193-198
    • /
    • 1993
  • Ultrasonography observations were made of the kidneys of 21 dogs. Ultrasonography images obtained in transverse and longitudinal planes. A 3.5-MHz linear transducer was used. All examinations were peformed on dogs in dorsal recumbency under anesthesia. The right kidney was 3.2~3.8cm long, 1.7~3.5 cm wide and 1.0~1.9cm deep in 0~5 of body weight group, 3.6~4.6cm long, 2.4~3.6cm wide and 1.4~2.1cm deep in 5~10 of body weight group, and 4.6~6.4cm long, 3.3~4.2cm wide and 2.0~2.0cm deep in 10~15kg of body weight group(p< 0.01). Diameter of the parenchyma of the right kidney ranged between 0.4~0.9cm in 0~5kg group, 0.6~1.0cm in 5~l0kg group and 0.9-1.1cm in 10~15kg group(p<0.01). Diameter of the renal sinus of the right kidney ranged between 0.3~0.5cm in 0~5kg group, 0.4~0.7cm in 5~10kg group and 0.5~0.9cm in 10~ 15kg group(p< 0.01). Similar ultrasonic measurements were obtained for the left kidney. It was concluded that the ultrasonographic findings described in this study can be used as references for diagnosis of morphologic changes in e canine kidney.

  • PDF

투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발 (Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance)

  • 김영석;송길목;방선배;김종민;최명일;김우진
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

자궁근종(子官筋腫)을 수반(隨伴)한 노년기(老年期) 초임(初任) 1례(例) - 초음파진단(超音波診斷)을 중심(中心)으로 - (A Study on One Case of Elderly Primigravida with Myoma Uteri - by Ultrasonic Diagnosis -)

  • 한혜진;문수형;김수희;김강석
    • 보험의학회지
    • /
    • 제2권1호
    • /
    • pp.260-266
    • /
    • 1985
  • Pregancy is a part of women's life and is common process experienced by most women. On the other hand, a few cannot be pregnant. There are many reasons of infertility and myoma uteri of pelvic mass is a rare reason of infertility. Complication of pregnancy accompanied with myoma uteri is largely affected by the size or location of mass and the incidence by myoma uteri in pregnancy rarely happened, but mass with long pedunculus causes torsion as uterus is getting bigger. In labor myoma uteri causes the abnormal condition of fetal presentation and results in the abnormal childbirth. In case of myoma uteri, maternal mortality is low and there by medical hazards also decrease, but as the life insurance medical is the extensive prediction science, we believe that the prediction of perinatal or the condition of afterbirth by knowing the location, size of myoma uteri contributes to the medical examination. We experienced one case of Elderly primigravida with myoma uteri in Med Dept of Dae Han Kyouk life Insurance Co. Ltd. which the insured with medical examination believe herself as menopause. So we report the observations with studies.

  • PDF

완관절의 초음파 소견 및 이용 (The Use and Findings of Ultrasound in the Wrist Joint)

  • 김정한;김주용;권용욱
    • 대한정형외과 초음파학회지
    • /
    • 제7권2호
    • /
    • pp.132-137
    • /
    • 2014
  • 고해상도 초음파 테크닉과 작은 탐촉자들이 개발되면서 표층에 위치하는 작은 구조물들에 대한 검사가 가능하게 되었고, 이로 인하여 초음파는 손목 질환의 진단과 치료에 유용한 도구가 되었다. 초음파를 이용할 때에는 이러한 기술적인 부분 뿐만 아니라 해부학적인 구조와 임상 양상을 잘 이해하여 적용하는 것이 중요하다. 손목의 통증 부위에 따른 대표적인 질환들에 대해 초음파의 접근방법 및 유용성을 정리해보고자 하였다.

  • PDF

Application of Laparospic Ultrasonography in Surgery of Small Renal Cell Carcinoma

  • Wang, Xiang-Zhu;Yu, Ze-Xing;Guo, Rui-Jun;Xing, Nian-Zeng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권21호
    • /
    • pp.9113-9116
    • /
    • 2014
  • Purpose: : To assess the clinic value of application of laparospic ultrasonography (LU) in partial nephrectomy of small renal cell carcinoma. Materials and Methods: From 2007 to 2011, 28 small renal cell carcinoma patients in ou clinic underwent laparoscopic partial nephrectomy with LU. For comparison with preoperative conventional ultrasound and CT, we collected ultrasonic performance of the affected side kidney, renal tumor location, size, echo change, blood supply situation and the relationship with the surrounding tissue. Results: LU could more clearly show the tumor interior structure and blood supply, as well as the relationship with the surrounding tissue. It also can provided doctor assistance with real-time tumor resection, reducing operative complications. Conclusions: LU can clearly show tumor internal structure and blood supply, which is helpful for explicit diagnosis. Moreover, it supplies accurate information for surgeons and assists surgery. Therefore LU has an important guiding value in partial nephrectomy for small renal cell carcinoma.

혈관 내부 진단용 원형 배열 초음파 트랜스듀서에 대한 연구 (A Study on an Ultrasonic Circular Array Transducer for Intra-vascular Ultra-sound Diagnosis)

  • 김희원;이수성;노용래
    • 한국음향학회지
    • /
    • 제22권4호
    • /
    • pp.329-336
    • /
    • 2003
  • 본 연구에서는 혈관 내부 조영용으로 사용될 수 있는 원형 배열 초음파 트랜스듀서를 설계하고 제작하였다. 트랜스듀서는 알루미나 튜브 위에 부착된 32개의 압전 소자와 전면 절연층, 고분자 후면층으로 구성된다. 우선 트랜스듀서의 방사특성 해석을 통해 원주방향으로 무지향성을 가지는 원형 배열 구조를 설계하였다. 압전소자로는 2-2형 압전복합재료를 채택하였다. 설계 결과에 따라 직경 3㎜의 원형 배열 트랜스듀서를 제작하고 그 음향특성을 측정하였으며, 측정 결과는 설계치와 잘 일치하였다. 실험적으로 확인된 무지향성은 본트랜스듀서의 IVUS (Intra-Vascular Ultra-Sound)센서로의 적용가능성을 확인시켜 주는 것이었다.

개에서 주위고환부고환염 1례 (A Case of the Periorchiepididymitis in a Dog)

  • 송강준;정성목;박성준;송근호;최호정;이영원;윤기영;신상태;조성환;조종기
    • 한국임상수의학회지
    • /
    • 제25권1호
    • /
    • pp.40-43
    • /
    • 2008
  • A 5-year-old male Shih-Tzu dog was referred with the primary complaint of scrotal swelling after surgery of urethrotomy 1 week ago. A diagnosis of the patient was made based on history taking, physical examination, laboratory examination, radiography, and ultrasonography. In the blood analysis, increase of leukocyte was seen. And there were enlarged and heterogeneous parenchyma of right testis in ultrasonic evaluation. The case was diagnosed as periorchiepididymitis and followed by treatment with bilateral orchiectomy and postoperative antibacterial agents. And conditions of patient were good.

다중계측기법을 이용한 원전 주증기배수밸브의 현상태 누설진단에 관한 연구 (A Study on the As-Built Leakage Diagnosis of Main Steam Drain Valves for Nuclear Power Plants by Multi-measuring Technique)

  • 김성영;김영범;김도형;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2606-2611
    • /
    • 2008
  • The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plants) decreases efficiency and consequently leads to considerable economic loss due to less power production. Also, the leakage possibly damages critical parts of components such as valve and trim with the effect of cavitation, flashing, and erosion, etc. and deteriorates its performance. Thus, in this study, we diagnosed the as-is leakage for four (4) main steam drain valves and two (2) steam traps of Yonggwang 1,2 units during normal operation by using multi-measuring technique and observed the occurrence of fine leakage. In the course of measuring fluid leakage, the sign of fine leakage is estimated to be the leakage from orifice. By converting the leakage to energy loss, it is equivalent to the amount of several hundred thousand won per each unit, which supports the basis for the justification of fine leakage.

  • PDF