• 제목/요약/키워드: Ultrasonic condition

검색결과 438건 처리시간 0.022초

A Technique for Measuring Ship's Draught by ultrasonic Pulse Signal

  • Lee, Eun-Bang;Lee, Sang-Jib
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1995년도 VTS and IBS 95 The Korean Institute of Navigation 1995년도
    • /
    • pp.184-192
    • /
    • 1995
  • Although ship's draught information onboard is substantial for both the safety of navigation and the estimation of loaded cargoes its accuracy depends in traditional surveying method on the skillfulness of observers and the condition of the sea surface round the vessel. To obtain more accurate information accessibly measuring instruments with sophisticated sensors such as mechanical electronic and ultrasonic transducers have been developed. however they have still limitation in accuracy and in making up a system due to the complexity of processing signal. In this paper we propose a he technique for analyzing ultrasonic pulse signal in order to improve the measurement accuracy and simplify a remote sensing system of draught by ultrasonic waves. This technique is useful for measuring draught being considered the influence of sea surface fluctuation and for transferring its data briefly to required equipment in integrated bridge system.

  • PDF

와이어 본딩시 본딩 패드 리프트 불량에 관한 연구 (Study on the Bonding Pad Lift Failure in Wire Bonding)

  • 김경섭;장의구;신영의
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1079-1083
    • /
    • 1998
  • In this study, ultrasonic power of Aluminum wire bonder, bond time and bond force are investigated and valued in order to minimize failure of bonding pad lift. We also tried to control those 3 factors properly. We got the conclusion that if we turn down the ability of ultrasonic power or bond time, we can get a pad lift from a boundary between bond pad ad wire because pad metal and wire joining is unstable, but it is best condition when it ultrasonic power is 100∼130unit, bond time is 15∼20msec and bond force is 4∼6gf.

  • PDF

Inverse Analysis of Ultrasonic Signals of Ceramics Based on Ultrasonic Self-Compensating Technique

  • Lee Joon-Hyun;Cheng Ansheng
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.185-190
    • /
    • 2006
  • An ultrasonic self-calibrating technique for the characterization of a ceramic which was fabricated by change pressing time during the HIP process has been applied by using the ratio of the reflection and transmission coefficients of normal incidence longitudinal waves. The ratio is self-compensated, in that it is independent of the characteristics for transmission and reception of ultrasound by the transducer and the condition of the couplant. The insensitive direction in parameter space is defined as the direction in which the variation of the ratio to changes of two parameters vanishes. For inverse problem the distribution of minima in an error surface is investigated.

음속의 응력의존성을 이용한 재료 상태평가에 대한 기초적 연구 (A Basic Research on Estimation of Material Condition by Using Stress Dependency of Sound Speed)

  • 김경조;장경영
    • 한국정밀공학회지
    • /
    • 제13권4호
    • /
    • pp.53-60
    • /
    • 1996
  • In the conventional linear elasticity, sound speed is determined by only elastic modulus and density of the medium. In actual, however, sound speed depends on the stress and this dependency becomes nonlinear as the stress increases. These phenomena can be introducing nonlinear elastic modulus. In this paper, relationships between nonlinear elastic modulus up to 4th order and the internal status of materials are discussed through computer simulations and experiments. For the measurement of sound speed, a new type of measurement system using ultrasonic wave is proposed on the basis of ultrasonic pulse echo method which has been generally used in nondestructive ultrasonic test equipment. In order to confirm the stress dependency of sound speed, several experiments are carried out for alumina specimen.

  • PDF

출토 직물의 세탁 방법에 따른 물성 변화 (Physical Property Change of Old Fabrics Depending on Cleaning Method)

  • 배순화;이미식
    • 복식
    • /
    • 제54권1호
    • /
    • pp.1-10
    • /
    • 2004
  • The purpose of this study was to compare the efficiency of four different cleaning method of silk and to fabrics, which were excavated from the sixteenth century tombs. The four cleaning methods were hand washing in water and hand washing in solvent, washing in ultrasonic cleaner, and using of ultrasonic gun after washing in ultrasonic cleaner. The following is the result of the experiment: ㆍBoth silk and jute fabrics shrank the most after hand-wash in water. This cleaning method decreased their thickness the most but changed their strength the least. However, the color of the fabric changed the most after had-wash in water. This washing method might discolor the dyed fabric, so one must check the condition of the fabric thoroughly before washing it. ㆍThe weight and the thickness of the fabric changed little after ultrasonic cleaning. This cleaning method, therefore. is less efficient than hand-water-wash. The use of ultrasonic gun after ultrasonic wash for partial cleansing enhanced the efficiency a little. Nevertheless, this method left stain around the area where the gun was used, and the injected water could damage the fabric. ㆍThe excavated fabric became softer in the cleaning process as the dirt was washed away. In both cases of silk and jute fabrics cleaning, solvent made the fabric softer than water. Washed in solvent, the fabric did not swell. But water penetrated to the fiber during the cleaning process and made the fabric swell. When the water evaporates, the swollen fiber structure collapses and the fabric become stiff. Ultrasonic wash did not cause much change in the flexibility of the fabric, for this method does not remove the dirt as effectively as the other method.

토양 세척 시 초음파 적용에 따른 유기 오염물 제거 특성 평가 (Removal Characteristics of Organic Contaminants by Ultrasonic Soil Washing)

  • 임찬수;김석구;김원재;고석오
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.72-79
    • /
    • 2014
  • Cavitation generated by ultrasonic irradiation can enhance the diffusional transport of organic contaminants from soil surfaces or pores. Therefore, ultrasound soil washing can be an alternative of traditional soil washing process. In this study, soil was artificially contaminated with n-tetradecane, n-hexadecane and phenanthrene. A plate type ultrasonic reactor at 25 kHz frequency and 1000W power was used for laboratory soil washing experiments. Ultrasonic soil washing efficiency was compared with those of traditional soil washing using mechanical mixing. Various operational parameter such as soil/liquid ratio, irradiation time, particle size, and soil organic matter content was tested to find out the optimum condition. It was found that ultrasonic soil washing demonstrates better performance than mechanical soil washing. Optimum soil:liquid ratio for ultrasonic soil washing was 1 : 5. Desorption of organic contaminants from soils by ultrasonic irradiation was relatively fast and reached equilibrium within 10 minute. However, decrease in the soil particle sizes by ultrasonic irradiation results in re-adsorption of contaminants to soil phase. It was also observed that soil particle size distribution and soil organic matter content have significant effects on the efficiency of ultrasonic soil washing.

적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어 (A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter)

  • 김중일;장준석;고상근
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

초음파 결합형 SBR 호기성 소화의 모델과 매개변수의 보정 (Numerical Model for SBR Aerobic Digestion Combined with Ultrasonication and Parameter Calibration)

  • 김성홍;이인호;윤정원;이동우
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.457-468
    • /
    • 2013
  • Based on the activated sludge model(ASM), a mathematical model which represents the aerobic sludge digestion by sequencing batch reactor(SBR) combined with ultrasonic treatment was composed and performed in this study. Aerobic digestion using sequencing batch reactor(SBR) equipped with ultrasound treatment was also experimented for the purpose of parameter calibration. Most of the presented kinetic parameters in ASM or ASM2 could be used for the aerobic digestion of sludge but the parameters related in hydrolysis and decay rate needed modification. Hydrolysis rate constant of organic matter in aerobic condition was estimated at $0.3day^{-1}$ and the maximum growth rate for autotrophs in aerobic condition was $0.618day^{-1}$. Solubilization reactions of particulate organics and nitrogen by ultrasonication was added in this kinetic model. The solubilization rate is considered to be proportional to the specific energy which is defined by specific ultrasound power and sonication time. The solubilization rate constant by ultrasonication was estimated at $0.202(W/L)^{-1}day^{-1}$ in this study. Autotrophs as well as heterotrophs also decomposed by ultrasonic treatment and the nitrification reaction was limited by the lack of autotrophs accumulation in the digester.

Ultrasonics and electromagnetics for a wireless corrosion sensing system embedded in structural concrete

  • Hietpas, K.;Ervin, B.;Banasiak, J.;Pointer, D.;Kuchma, D.A.;Reis, H.;Bernhard, J.T.
    • Smart Structures and Systems
    • /
    • 제1권3호
    • /
    • pp.267-282
    • /
    • 2005
  • This work describes ongoing development of an embedded sensor system for the early detection and prevention of deterioration of reinforcing steel tendons within reinforced concrete. These devices will evaluate the condition of the steel tendon using ultrasonic techniques and then wirelessly transmit this data to the outside world without human intervention. The ultrasonic transducers and the interpretation of the sensed signals that allow detection and prognosis of tendon condition are detailed. Electrical characterization of concrete mixtures used in bridge construction is conducted and a wideband microstrip antenna is designed and fabricated to operate between 2.4 and 2.5 GHz when embedded in such a medium. Simulations and measurements of the embedded antenna element are presented. Transceiver selection and implementation are discussed as well as future work in operational protocols, sensor networking, and power sources. By implementing commercially available off-the-shelf components whenever possible, these devices have the potential to save millions of dollars a year in evaluation, repair and replacement of reinforced concrete.

Effect of curing treatments on the material properties of hardened self-compacting concrete

  • Salhi, M.;Ghrici, M.;Li, A.;Bilir, T.
    • Advances in concrete construction
    • /
    • 제5권4호
    • /
    • pp.359-375
    • /
    • 2017
  • This paper presents a study of the properties and behavior of self-compacting concretes (SCC) in the hot climate. The effect of curing environment and the initial water curing period on the properties and behavior of SCC such as compressive strength, ultrasonic pulse velocity (UPV) and sorptivity of the SCC specimens were investigated. Three Water/Binder (W/B) ratios (0.32, 0.38 and 0.44) have been used to obtain three ranges of compressive strength. Five curing methods have been applied on the SCC by varying the duration and the conservation condition of SCC. The results obtained on the compressive strength show that the period of initial water curing of seven days followed by maturation in the hot climate is better in comparison with the four other curing methods. The coefficient of sorptivity is influenced by W/B ratio and the curing methods. It is also shown that the sorptivity coefficient of SCC specimens is very sensitive to the curing condition. The SCC specimens cured in water present a low coefficient of sorptivity regardless of the ratio W/B. Furthermore, the results show that there is a good correlation between ultrasonic pulse velocity and the compressive strength.