• 제목/요약/키워드: Ultrasonic Transducers

검색결과 252건 처리시간 0.023초

초음파를 이용한 배면웨지의 일방향 비파괴 특성평가 (One-Sided Nondestructive Evaluation of Back-Side Wedge By Using Ultrasonic Sound)

  • 정종안;;임광희
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.773-777
    • /
    • 2011
  • Conventional ultrasonic thickness measurement is to be considered as the assumption that the ultrasonic velocity is known. In actual applications the velocity is often not well known and access is often limited to one side. This paper aims at determining the ultrasonic velocity and thickness of plates with parallel or wedged surfaces using contact measurements made on one surface only. For wedged plates the thickness at one point and the wedge angle are determined. Equations are used for determining the ultrasonic velocity, thickness and wedge angle of the plate based on the times-of-flight measured by two contact transducers coupled to one surface. The time-of-flight of the obliquely reflected longitudinal wave echo was measured as a function of the separation between the two transducers. In addition, a simulation was made for comparing the experimental data and a FEM image. Experiments and simulations were performed on flat and wedged plates of aluminium materials; the calculated results for the unknown quantities are generally agreed with them to some degree.

실린더형 구조물의 원거리 초음파검사용 나선형 코일 자왜 스트립 변환기 (Spiral Coil Magnetostrictive Strip Transducers for Long Range Ultrasonic Testing of Cylindrical Structures)

  • 허원녕;최명선
    • 비파괴검사학회지
    • /
    • 제28권5호
    • /
    • pp.416-420
    • /
    • 2008
  • 전자기음향변환기 분야에서는 나선형 RF 코일이 솔레노이드 코일보다 훨씬 널리 사용되고 있다. 그러나 실린더 구조물의 원거리 초음파검사용 자왜 스트립 도파변환기 분야에서는 솔레노이드 코일이 주로 사용되어왔다. 이는 아마도 낮은 주파수의(즉, 치수가 큰) 나선형 코일의 제작의 어려움에 기인하는 것 같다. 본 논문에서는 FFC(flexible flat cable)로 나선형 코일 자왜 스트립 도파변환기를 제작하는 방법을 기술한다. 기존의 솔레노이드 코일 변환기와의 비교실험을 통하여 나선형 코일 변환기가 훨씬 우수한 성능(감도, 신호-대-잡음 비, 도파방향조정능력)을 갖는다는 것을 실증한다.

압전 초음파 센서를 이용한 수중통신에 관한 연구 (A Study on the underwater communication system of ultrasonic transducer)

  • 김동현;우형관;황현석;진홍범;송준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1658-1660
    • /
    • 2000
  • Simple signs were usually exchanged as the means of underwater communications. As people recently, need more informations for underwater activities, necessities of underwater communication systems exchanging hunman voice are increased. The purpose of this paper is understanding the ordinary characteristics of underwater communication and investigating the necessary conditions for a good underwater communication system by making a basic communication module. The experiment is achieved by applying AM (Amplitude Modulation) which is mainly used for the underwater communication systems and using common ultrasonic transducers. Ultrasonic transducers usually have narrow bandwidth for transducing electrical energy to mechanical energy. For improvement of sound reconstruction, transducers need more bandwidth which covers voice's frequency range, and goof linearity characteristics in this frequency range. As underwater transmissions have many factors to distort signals. Amplitude Modulation is not a proper way for underwater communications. Using digital signal by sampling human voice should be a good way for this systems, because digital communication simplify transmitting signals.

  • PDF

PZT 압전 세라믹스를 사용한 2중 모우드 초음파 트랜스듀서 제작 (Fabrication of dual mode ultrasonic transducers with PZT piezoelectric ceramics)

  • 김연보;노용래;남효덕
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.572-579
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigate the mechanism of dual mode transducers that generate both of the longitudinal and shear waves simultaneously with single PZT element. The study is aimed to find the optimally desired cut by examining the anisotropic piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a rotated Z-cut of PZT piezoelectric ceramics. We study the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves as much as equally strong. The results are verified by the waveform in pulse-echo computer simulation and experiments. When the transducer is subjected to impedance analysis, it shows two thickness mode resonances, each of which being a mixed P/S thickness mode. By examining wave speeds on E transmitter delay line receiver setup, it is confirmed that the transducer can transmit and detect both longitudinal and shear wave simultaneously.

  • PDF

적층 압전 변환기의 진동 특성 (Vibration Characteristics of Stacked Piezoelectric Transducers)

  • 김대종;김진오
    • 한국소음진동공학회논문집
    • /
    • 제25권3호
    • /
    • pp.199-206
    • /
    • 2015
  • This paper deals with the vibration characteristics of stacked transducers composed of piezoelectric discs, which are main elements of ultrasonic sensors or actuators. The stacked transducers were devised in the sense of natural frequencies. Two- or three-layer transducers were fabricated with piezoelectric discs of different diameters. The natural frequencies were determined by the finite element analysis and they were verified by comparing them with experimental results. It appeared that the natural frequencies of the stacked piezoelectric transducers include the natural frequencies of the constituent piezoelectric discs and the natural frequencies caused by stacking. Based on these results, it would be possible to predict the vibration characteristics of the stacked piezoelectric transducers in a design process.

Acoustic Properties of Bovine Cancellous Bone in the Frequency Range of 0.5-2 MHz

  • Lee Kang Il;Roh Heui-Seol;Yoon Suk Wang
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.373-376
    • /
    • 2002
  • Most previous studies using ultrasound for osteoporosis diagnosis have employed ultrasound in a frequency range of 0.2-1 MHz. In this study, acoustic properties of the 12 defatted bovine cancellous bone specimens were investigated in vitro. Speed of sound (SOS) and broadband ultrasonic attenuation (BUA) were measured using three matched pairs of transducers with the center frequencies of 1, 2.25, and 3.5 MHz, respectively, in order to cover a broad frequency range of 0.5-2 MHz. The relative orientation between ultrasonic beam and bone specimens was the mediolateral (ML) direction of the bovine tibia. SOS showed significant linear positive correlations with apparent density for all three pairs of transducers of 1 MHz, 2.25 MHz, and 3.5 MHz, respectively. BUA showed relatively weak correlations with apparent density for the pairs of transducers of 1 MHz and 2.25 MHz. Furthermore, in the measurement with the pair of 3.5 MHz transducers, BUA was independent of apparent density. SOS and BUA were only weakly correlated with each other. The linear combination of SOS and BUA showed significant correlations with apparent density. These results suggest that the frequency range up to 1.5 MHz may be also useful in the osteoporosis diagnosis.

  • PDF

고지향성 압전 트랜스듀서용 새로운 고효율 전력 증폭기 (New High-efficiency Power Amplifier System for High-directional Piezoelectric Transducer)

  • 김진영;김인동;문원규
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.383-390
    • /
    • 2018
  • Piezoelectric micro-machined ultrasonic transducers for highly directional speaker need DC bias voltage. Most existing power amplifiers are not suitable for use in highly directional transducers because they are based on AC. In addition, since the piezoelectric micro-machined ultrasonic transducer has a large capacitive reactance, the power efficiency of the power amplifier is very low. Thus this paper proposes a new high efficiency power amplifier with DC bias voltage. In addition, by designing a matching circuit to compensate the capacitive reactance of the micro-machined ultrasonic transducer, the power efficiency of the power amplifier increases. The operating characteristics of the proposed power amplifier was verified by an experimental prototype. The proposed power amplifier is expected to be widely used in designing and implementing other related power amplifiers.

압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구 (A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer)

  • 이수성;김영신;노용래
    • 한국음향학회지
    • /
    • 제21권1호
    • /
    • pp.56-61
    • /
    • 2002
  • 초음파 진단용으로 널리 사용되는 1차원 배열 압전형 초음파 변환기는 변환기내의 인접한 소자들간의 간섭에 의해 그 특성에 많은 영향을 받는다. 따라서 본 연구에서는 유한 요소 해석법을 이용하여 압전형 1차원 배열 의료용 초음파 변환기에서 커프의 충진재와 형상의 변화에 의한 음향간섭 레벨의 경향을 분석하였다. 분석결과는 향후 진단용 초음파 변환기의 최적 설계를 위해 중요한 자료가 될 것이며, 더 나아가 치료용, 비파괴 검사용, 그리고 수중 초음파 변환기에도 적용이 가능할 것이다.

유속 측정용 초음파 트랜스듀서의 탄성파 에너지 투과율 (Energy Transmission of Elastic Waves in Ultrasonic Transducers for Flow Velocimetry)

  • 박춘광;김대종;김진오;김동현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.733-735
    • /
    • 2014
  • The paper deals with the energy transmission ratio of the elastic waves obliquely transmitting through a plate and a pipe. The incidence angle corresponding to the maximum transmission was determined theoretically and considered in the design of ultrasonic transducers for flow velocimetry. Experimentally-obtained transmission ratios were compared with and confirmed the theoretically-calculated results.

  • PDF

초음파를 이용한 CFRP 복합재의 일방향 비파괴 평가 (One-Sided Nondestructive Evaluation of CFRP Composites By Using Ultrasonic Sound)

  • 임광희;장계림;최성록;예창희;류제성;임수환;한민규
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.47-52
    • /
    • 2011
  • It is well known that stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences their properties. Ultrasonic NDE of composite laminates is often based on the backwall echoes of the sample. A pair of such transducers was mounted in a holder in a nose-to-nose fashion to be used as a scanning probe on composites. Miniature potted angle beam transducers were used (Rayleigh waves in steel) on solid laminates of composites. Experiments were performed to understand the behavior of the transducers and the nature of the waves generated in the composite (mode, wave speed, angle of refraction). C-scan images of flaws and impact damage were then produced by combining the pitch-catch probe with a portable manual scanner known as the Generic Scanner ("GenScan"). The pitch-catch signal was found to be more sensitive than normal incidence backwall echo of longitudinal wave to fiber orientation of the CFRP composites, including low level porosity, ply waviness, and cracks. Therefore, it is found that the experimentally Rayleigh wave variation of pitch-catch ultrasonic signal was consistent with numerical results and one-side ultrasonic measurement might be very useful to detect the defects.